contact lens sensor
Recently Published Documents


TOTAL DOCUMENTS

71
(FIVE YEARS 6)

H-INDEX

16
(FIVE YEARS 0)

2021 ◽  
Vol 10 (16) ◽  
pp. 3472
Author(s):  
Bojan Pajic ◽  
Mirko Resan ◽  
Brigitte Pajic-Eggspuehler ◽  
Horace Massa ◽  
Zeljka Cvejic

Background: The aim of the study is to investigate whether the circadian IOP rhythm can be influenced by combined cataract surgery with high frequency deep sclerotomy (HFDS) and whether intraocular pressure (IOP) can be significantly reduced by HFDS. Methods: In our study 10 patients were included, in whom 24 h IOP monitoring was installed before and after HFDS/cataract surgery using a Triggerfish. HFDS is a minimally invasive glaucoma surgery (MIGS). Results: After performed HFDS combined with cataract surgery, the IOP was reduced from 27.7 ± 2.11 mmHg to 14.4 ± 2.59 mmHg, which is highly significant (p < 0.001). The contact lens sensor (CLS) cosinor analysis pre- and postoperatively showed that the circadian rhythm is not influenced by the surgery, i.e., the circadian IOP rhythm did not show significant differences before and after surgery. Conclusions: HFDS combined with cataract surgery is a potent surgical method that can significantly reduce the IOP. However, the circadian rhythm cannot be changed by the surgery. The acrophase remained during the night in all patients.


2021 ◽  
Vol 321 ◽  
pp. 112580
Author(s):  
I.K. Karunaratne ◽  
Ching Hymn Christopher Lee ◽  
Ping Wai Or ◽  
Yifan Wei ◽  
Iok Tong Chong ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248211
Author(s):  
Kevin Gillmann ◽  
Robert Wasilewicz ◽  
Kirsten Hoskens ◽  
Sonja Simon-Zoula ◽  
Kaweh Mansouri

Purpose To address the unmet need of continuous IOP monitoring, a Pressure-Measuring Contact Lens (PMCL) was developed to measure IOP in millimeters of mercury (mmHg) continuously over 24 hours. The present study assessed the reliability of the novel PMCL. Methods In this prospective open-label clinical study, healthy and open-angle glaucoma (OAG) subjects were fitted with the PMCL, and pneumatonometry was performed on study eyes (in absence of the PMCL) and on fellow eyes before, during, and after provocative tests. The primary outcome measures were (1) mean IOP difference between same-eye measurements, and (2) percentage of timepoints at which IOP measured by the PMCL was within 5 mmHg of that measured by pneumatonometry in the fellow eye. Results Eight subjects were analysed (4 healthy, 4 OAG). The average difference in successive IOP measurements made by pneumatonometry and with the PMCL was 2.0±4.3mmHg at placement-time, and 6.5±15.2mmHg at removal time. During water drinking test, a significant increase in IOP was detected both by PMCL in the study eye (2.4±2.5mmHg, p = 0.03) and by pneumatonometry in the fellow eye (1.9±1.9mmHg, p = 0.02). Over the 24-hour recording, 88.0% of IOP variations measured by the PMCL were within 5mmHg of that measured with the pneumatonometer in the fellow eye. A transient corneal erosion of severe intensity was observed following removal of the PMCL on one single eye, and may have affected measurement accuracy in that eye. Conclusions This study is a proof-of-concept for this novel PMCL, and its results are encouraging, with a fair accuracy in IOP values measurement and good sensitivity to subtle IOP variations.


2020 ◽  
Vol 32 (9) ◽  
pp. 095106
Author(s):  
Yanyan Fan ◽  
Hailing Tu ◽  
Hongbin Zhao ◽  
Feng Wei ◽  
Yi Yang ◽  
...  

Matter ◽  
2020 ◽  
Author(s):  
Shiqi Guo ◽  
Kaijin Wu ◽  
Chengpan Li ◽  
Hao Wang ◽  
Zheng Sun ◽  
...  

2020 ◽  
Vol 1571 ◽  
pp. 012005
Author(s):  
E V Panfilova ◽  
K V Mozer ◽  
A R Ibragimov

Sign in / Sign up

Export Citation Format

Share Document