fracture table
Recently Published Documents


TOTAL DOCUMENTS

101
(FIVE YEARS 4)

H-INDEX

17
(FIVE YEARS 0)

Author(s):  
Stephen Adesope Adesina ◽  
Samuel Uwale Eyasan ◽  
Isaac Olusayo Amole ◽  
Olufemi Timothy Awotunde ◽  
Akinsola Idowu Akinwumi ◽  
...  

2021 ◽  
pp. 77-79
Author(s):  
Nilabh Kumar ◽  
Laljee Chaudhary ◽  
Debarshi Jana

Background:The proximal femoral nail (PFN) used as an intramedullary device for the treatment of fractures. Objectives: Study was taken to analyse the union of the subtrochanteric fracture, internally xed with PFN. Materials and Methods: Study was conducted in the Department of Orthopaedics, DMCH, Laheriasarai, Bihar from June 2019 to November 2019. Individuals with acute subtrochanteric femur fractures >18 years were included in the study. The patient was positioned supine on the fracture table under spinal or epidural or general anesthesia as the condition of the patient permitted. Pre-operatively one dose of antibiotic was also administered. The fracture was reduced by longitudinal traction on fracture table and the limb was placed in neutral or slight adduction to facilitate nail insertion through the greater trochanter ; P <0.05 was considered statistically signicant. Results: At the end of ve months, all except three patients could mobilise independently; statistically there was signicant difference (P<0.05). Based on Harris Hip score obtained 3 patients outcome was excellent, 18 patients were good and 4 patients had fair outcome. Conclusion: Minimal exposure, better stability and early mobilization are the advantages with PFN. Fractures united in all cases and postoperative functional outcome was satisfactory. PFN could be a preferred implant of choice in treating subtrochanteric fractures especially in elderly.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Wei Shui ◽  
Youyin Yang ◽  
Xinling Pi ◽  
Gang Luo ◽  
Bo Qiao ◽  
...  

Abstract Background Faster, easier, more economical and more effective versions of the minimally invasive reduction procedure for femoral shaft fractures need to be developed for use by orthopaedic surgeons. In this study, a fracture table was used to restore limb length, and long, curved haemostatic forceps and the lever principle were utilized to achieve minimally invasive reduction and intramedullary nail fixation of femoral shaft fractures. Methods A retrospective analysis involving 20 patients with femoral shaft fractures reduced with a fracture table; long, curved haemostatic forceps; and the lever principle was conducted. The operative effect was evaluated on the basis of the operative time, reduction time, fluoroscopy time, and intraoperative blood loss. Results All 20 cases were reduced in a closed fashion, and no conversions to open reduction were needed. The average operative time and fracture reduction time for all patients were 69.1 ± 13.5 min (range, 50–100 min) and 6.7 ± 1.9 min (range, 3–10 min), respectively. The fluoroscopy exposure time during the reduction process was 5–15 s, with an average time of 8.7 ± 2.7 s. The average intraoperative blood loss was 73.5 ± 22.5 mL (range, 50–150 mL). The patients exhibited excellent alignment in the injured limb after intramedullary nailing. Seventeen patients successfully completed a follow-up after fracture healing. The healing time ranged from 4 to 6 months. Conclusions Displaced femoral shaft fractures in adults can be treated by a labour-saving lever technique involving fragments, 2 haemostatic forceps and soft tissue envelope-assisted closed reduction and intramedullary nail fixation. This technique is easy to perform; reduces blood loss, the fluoroscopy time and the surgical time for intraoperative reduction; and leads to excellent fracture healing.


Medicine ◽  
2021 ◽  
Vol 100 (2) ◽  
pp. e24233
Author(s):  
Sang-Min Lee ◽  
Kuen Tak Suh ◽  
Young Kwang Oh ◽  
Won Chul Shin

2020 ◽  
Author(s):  
Wei Shui ◽  
Youyin Yang ◽  
Xinling Pi ◽  
Gang Luo ◽  
Bo Qiao ◽  
...  

Abstract Background: Faster, easier, more economical and more effective versions of the minimally invasive reduction procedure for femoral shaft fractures need to be developed for use by orthopaedic surgeons. In this study, a fracture table was used to restore limb length, and long, curved haemostatic forceps and the lever principle were utilized to achieve minimally invasive reduction and intramedullary nail fixation of femoral shaft fractures.Methods: A retrospective analysis involving 20 patients with femoral shaft fractures reduced with a fracture table; long, curved haemostatic forceps; and the lever principle was conducted. The operative effect was evaluated on the basis of the operative time, reduction time, fluoroscopy time, and intraoperative blood loss.Results: All 20 cases were reduced in a closed fashion, and no conversions to open reduction were needed. The average operative time and fracture reduction time for all patients were 69.1±13.5 minutes (range, 50–100 minutes) and 6.7±1.9 minutes (range, 3–10 minutes). The fluoroscopy exposure time during the reduction process was 5–15 seconds, with an average time of 8.7±2.7 seconds. The average intraoperative blood loss was 73.5±22.5 mL (range, 50–150 mL). The patients exhibited excellent alignment in the injured limb after intramedullary nailing. Seventeen patients successfully completed a follow-up after fracture healing. The healing time ranged from 4 to 6 months.Conclusions: Displaced femoral shaft fractures in adults can be treated by a labour-saving lever technique involving fragments, 2 haemostatic forceps and soft tissue envelope-assisted closed reduction and intramedullary nail fixation. This technique is easy to perform; reduces blood loss, the fluoroscopy time and the surgical time for intraoperative reduction; and leads to excellent fracture healing.


2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Carlos Suarez-Ahedo ◽  
Anell Olivos-Meza ◽  
Parth Lodhia

2020 ◽  
Vol 04 (01) ◽  
pp. 033-037
Author(s):  
Samantha Andrews ◽  
Gregory J. Harbison ◽  
Ian Hasegawa ◽  
Emily Unebasami ◽  
Cass Nakasone

AbstractThe cementless, tapered wedge, short femoral stem implant is commonly used in direct anterior approach (DAA) total hip arthroplasty (THA). The lack of access and visualization, however, may increase the risk of perioperative fracture and early failure. Therefore, the current study examined perioperative complications and 2-year implant survivorship following DAA THA performed using a fracture table and short, tapered wedge femoral stem. A retrospective analysis was conducted on patients having undergone DAA THA with a cementless, tapered wedge, short femoral stem. Perioperative fractures were noted and survivorship was determined by the incidence of revision surgery within a minimum 2-year follow-up period. A total 366 consecutive patients (441 hips) were identified in the cohort. Four patients (6 hips; 1.4%) were lost to follow-up and three patients died from unrelated causes. Average follow-up time for the remaining 359 patients (435 hips) was 32.9 ± 10.2 months. There were no intraoperative factures but three perioperative fractures within two weeks. Aseptic loosening occurred in one stem at 13 months, resulting in a 99.1% survival rate with a mean survival time of 23.8 ± 0.1 months (95% confidence interval: 23.6–24.0 months). The use of a short, tapered wedge femoral stem and a fracture table for DAA THA resulted in 0.7% periprosthetic fractures and only one aseptic loosening within 2 years. These results suggest that proper femoral exposure with the use of a fracture table and a short, tapered wedge femoral stem does not appear to increase the risk of periprosthetic femoral fracture.


Injury ◽  
2020 ◽  
Vol 51 (2) ◽  
pp. 429-435
Author(s):  
Luc Rubinger ◽  
Daniel Axelrod ◽  
Anthony Bozzo ◽  
Aaron Gazendam ◽  
Jamal Al-Asiri ◽  
...  

2019 ◽  
Author(s):  
Daniel Axelrod ◽  
Herman Johal ◽  
Kim Madden ◽  
Francesc Marcano ◽  
Carlos Prada

Background: Femoral Shaft fractures are devastating and life threatening injuries. Femoral shaft fractures are most commonly treated with intramedullary fixation. Malrotation of the injured limb after fixation is a common and significant complication following femoral shaft fractures. During the operation, patients can be positioned either supine or in a lateral position. Additionally, patients can be placed on a standard radiolucent operating room table, or placed on a fracture table with traction statically applied to the operative limb throughout the case. Previous case series and cohort studies have shown equivalence between study groups, but choice between positioning options remains controversial. Methods: This represents a protocol for a randomized controlled pilot trial. We will be compared lateral positioning with use of manual traction to supine positioning with use of a fracture table. Primary outcomes will be in assessment for feasibility for a future full scale randomized trial, including evaluating patient recruitment, patient compliance with followup, contamination between treatment arms and others. Results: The primary outcome will be feasibility for a future trial. Secondary outcomes will include malrotation as measured through postoperative computed tomography scans and gait analysis at 6 months.


Sign in / Sign up

Export Citation Format

Share Document