condensate pump
Recently Published Documents


TOTAL DOCUMENTS

33
(FIVE YEARS 1)

H-INDEX

3
(FIVE YEARS 0)

2021 ◽  
Vol 8 (1) ◽  
pp. 259-264
Author(s):  
Yolnasdi

Net Plant Heat Rate (NPHR) merupakan indikator kehandalan dan efisiennya sebuah pembangkit thermal khususnya PLTU. Semakin kecil nilai NPHR maka PLTU dinyatakan semakin efisien dan sebaliknya. Terdapat 3 parameter utama yang menunjukkan indikasi perubahan nilai NPHR suatu PLTU yaitu beban (load) neto yang disuplai oleh PLTU, jumlah konsumsi batubara dan nilai kalori batubara. Semakin besar beban neto yang disalurkan PLTU ke jaringan, maka nilai NPHR akan semakin kecil atau bagus. Dalam monitoring NPHR PLTU UBJOM Tenayan unit 1 menggunakan perhitungan metode input-output terdapat indikasi peningkatan nilai NPHR yang berbanding lurus dengan meningkatnya nilai auxiliary power. Meningkatnya nilai auxiliary power berkaitan erat dengan beban neto yang dihasilkan oleh PLTU ke jaringan. Pada penelitian ini dilakukan pemecahan solusi dengan melakukan performance test untuk mendapatkan data yang dibutuhkan dalam perhitungan NPHR metode heat loss. Perhitungan dengan metode heat loss memiliki keunggulan untuk mengklasifikasi faktor yang menyebabkan peningkatan NPHR. Dengan mengetahui faktor losses tersebut, root cause failure dapat ditemukan  dan penyusunan  failure defense task yang direncanakan semakin akurat. Dari hasil penelitian yang dilakukan, auxiliary power merupakan penyumbang nilai NPHR terbesar yang masuk dalam kategori plant controllable. Melalui penyusunan managemen auxiliary power berbasis pareto yang telah dilakukan, ditemukan 5 peralatan main auxiliary yaitu SA Fan, BFP, Condensate Pump, CWP dan cooling fan yang menjadi sumber penyebab meningkatnya main auxiliary power sebesar 2% dan berdampak pada losses sebesar 55,16 kCal/kWh serta loss production sebesar  Rp. 24,602,765.81 per-hari.


JTAM ROTARY ◽  
2020 ◽  
Vol 2 (2) ◽  
pp. 207
Author(s):  
Muhammad Rizky Hidayat ◽  
Aqli Mursadin

Gland Steam Condensor (GSC) adalah alat penukar panas yang mengembunkan uap dari segel poros turbin. Steam bekas ini akan memanaskan air kondensat dari pompa kondensat yang dialirkan melintasi kondensor Gland Steam. Karena panas diserap oleh air kondensat, maka steam bekas dari seal poros akan mengembun kemudian dialirkan ke hotwell hingga bercampur dengan air hotwell. Dari hasil penelitian koefisien perpindahan kalor tertinggi pada tabung adalah 80.491,93 btu/hr ft2 pada hari Rabu jam 14.00. Diketahui bahwa koefisien perpindahan panas pada tabung terendah adalah 79.011,94 btu/hr ft2 pada hari Senin jam 16.00. Koefisien perpindahan panas tertinggi pada cangkang adalah 5.294.695 btu/jam ft2 pada hari Jumat pukul 14.00, koefisien perpindahan panas cangkang terendah adalah 2.762.553 btu/jam ft2 pada hari Selasa pukul 11.00. Perpindahan panas aktual tertinggi adalah 1.528.694.1 btu/jam hari Jumat jam 14.00, perpindahan panas aktual terendah adalah 713.159.522 btu/jam pada hari Kamis jam 8.00. Diketahui laju perpindahan kalor maksimum sebesar 1.797.918 btu/jam pada pukul 14.00, laju perpindahan kalor maksimum sebesar 790.348 btu/jam pada hari Kamis pukul 08.00. Diketahui efisiensi tertinggi sebesar 90,25% pada hari Kamis pukul 08.00. Dengan efisiensi rata-rata antara kisaran 86,29%. Gland Steam Condensor (GSC) is a heat exchanger it condenses steam from a turbine shaft seal. This used steam will heat condensate water from a condensate pump which is flowed across Gland Steam condensor. Because the heat is absorbed by condensate water, used steam from the shaft seal will condense and then flow to hotwell until it mixes with hotwell water.  From the results of the study the highest heat transfer coefficient on the tube is 80,491.93 btu/hr  on Wednesday at 2:00 p.m. It is known that the heat transfer coefficient on the lowest tube is 79,011.94  btu/hr on Monday at 4:00 p.m. The highest heat transfer coefficient on the shell is 5,294,695 btu/hr on Friday at 14:00, the lowest shell heat transfer coefficient is 2,762,553 btu/hr on Tuesdayat 11: 00. The highest actual heat transfer is 1,528,694.1 btu/hr on Friday at 2:00 p.m., the lowest actual heat transfer is 713,159,522 btu/hr on Thursday at 8:00. It is known that the maximum heat transfer rate is 1,797,918 btu/hr at 2:00 p.m., the maximum heat transfer rate is 790,348 btu/hr on Thursday at 8:00. It is known that the highest efficiency is 90.25% on Thursday at 8:00. With average efficiency between the range of 86.29%.


2020 ◽  
Vol 18 (4) ◽  
pp. 614-617
Author(s):  
Ezhov Sergeevich ◽  
Semicheva Evgenievna ◽  
Ezhova Vladimirovna ◽  
Brezhnev Viktorovich

The work relates to the technique of desalination of sea and saline waters and can be used to obtain desalinated water with generation of electrical energy. The proposed technology of water desalination is implemented by an autonomous solar desalination-electric generator, containing a rectangular body, the roof of which is covered from above with photocells with a storage unit, an inclined evaporating tray is placed inside the body, dividing the body cavity into evaporation and condensation chambers, communicating with each other at the sides of the body through vertical slots at the ends of the body and the tray are an inlet manifold connected to a submersible feed pump, and a horizontal outlet slot. The bottom of the body is connected to a condensate collection tank, in which a condensate pump is placed, a condensation chamber, immersed in a reservoir, the inner surface of the ends, sides and bottom of the condensation the chamber is made with vertical and horizontal corrugations, into the grooves of which thermoelectric converters are inserted. The first and last of which with photocells are connected to the output collectors, a storage unit, feed and condensate pumps and other them as consumers of electricity.


Author(s):  
Wanjun Li ◽  
Xiaoxia Li ◽  
Qingliang Niu ◽  
Tianqi Huang ◽  
Deke Zhang ◽  
...  
Keyword(s):  

2019 ◽  
Vol 118 ◽  
pp. 02064
Author(s):  
Guangyao Ma ◽  
shuai Zhang ◽  
Fanyang Meng

The key equipment of thermal power plants such as feed pump, condensate pump, circulating pump and induced draft fan, blower fan, oxidation fan, air preheater’s vibration information are monitored and tracked. Bearing failure accounted for the largest proportion. Problems such as misalignment and unbalance are still very common. Attention should be paid to the fault diagnosis and maintenance work.


Author(s):  
Can Kang ◽  
Haixia Liu ◽  
Ning Mao ◽  
Yongchao Zhang
Keyword(s):  