harmonic restraint
Recently Published Documents


TOTAL DOCUMENTS

27
(FIVE YEARS 1)

H-INDEX

6
(FIVE YEARS 0)

Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8284
Author(s):  
Abdul Azeem ◽  
Majid Jamil ◽  
Shamimul Qamar ◽  
Hasmat Malik ◽  
Rayees Ahmad Thokar

In this paper, the authors have developed a hardware model for blocking even and odd harmonics of a power transformer. In the proposed hardware model, intelligent differential & over-current relays are used for the blocking of harmonics of a power transformer. The harmonic restraint function on the differential relay (7UT61) prevents the relay from tripping during transformer magnetizing inrush current. However, the over-current relays which are used for back up protection does not have a harmonic restraint element, and over-current relay trips due to magnetizing inrush current, causes unwanted interruptions and power failures. The establishment of harmonic blocking scheme for over-current protection in power transformers is an important finding of this research study. IEC61850 standard-Based GOOSE (Generic Object Oriented Substation Event) applications used in power transformer protection for fast detecting and clearing of faults is an interested study presented in the proposed work.


Author(s):  
Azniza Ahmad ◽  
Mohammad Lufti Othman ◽  
Kurreemun Khudsiya Bibi Zainab ◽  
Hashim Hizam

Power transformer is the most expensive equipment in electrical power system that needs continuous monitoring and fast protection response. Differential relay is usually used in power transformer protection scheme. This protection compares the difference of currents between transformer primary and secondary sides, with which a tripping signal to the circuit breaker is asserted. However, when power transformers are energized, the magnetizing inrush current is present and due to its high magnitude, the relay mal-operates. To prevent mal-operation, methods revolving around the fact that the relay should be able to discriminate between the magnetizing inrush current and the fault current must be studied. This paper presents an Artificial Neural Network(ANN) based differential relay that is designed to enable the differential relay to correct its mal-operation during energization by training the ANN and testing it with harmonic current as the restraining element. The MATLAB software is used to implement and evaluate the proposed differential relay. It is shown that the ANN based differential relay is indeed an adaptive relay when it is appropriately trained using the Network Fitting Tool. The improved differential relay models also include a reset part which enables automatic reset of the relays. Using the techniques of 2nd harmonic restraint and ANN to design a differential relay thus illustrates that the latter can successfully differentiate between magnetizing inrush and internal fault currents. With the new adaptive ANN-based differential relay, there is no mal-operation of the relay during energization. The ANN based differential relay shows better performance in terms of its ability to differentiate fault against energization current. Amazingly, the response time, when there is an internal fault, is 1 ms compared to 4.5 ms of the conventional 2nd harmonic restraint based relay.


Energies ◽  
2019 ◽  
Vol 12 (15) ◽  
pp. 2911 ◽  
Author(s):  
Wenbin Cao ◽  
Xianggen Yin ◽  
Yongxin Chen ◽  
Yuanlin Pan ◽  
Xiangyuan Yin ◽  
...  

In recent years, the zero-mode inrush current of high-impedance transformer with built-in high-voltage winding (T-Hin), which has large amplitude and decays slowly, causes the misoperation of zero-sequence overcurrent protection. Compared with magnetizing inrush current, the waveform of zero-mode inrush current is inconsistent and irregular, and few researches have proposed the mathematical analysis as well as the improved protection using waveform characteristics. In this paper, the mathematical expression of transformer zero-mode inrush current is derived. Further considering the parameter differences, the zero-mode inrush current of T-Hin is larger, which tends to cause the misoperation. The mathematical waveforms fit well with the recorded waveforms. Both recorded waveforms and mathematical waveforms in various conditions prove that the second harmonic ratio (the ratio between the second harmonic and first harmonic) of zero-mode inrush current is significant. Based on the above analysis, a criterion based on the second harmonic ratio restraint of zero-mode inrush current is proposed. If the second harmonic ratio exceeds the setting value, it is considered that the inrush current is generated and sends a signal to restrain the protection. The theoretical setting value of the proposed criterion and the practical engineering method for determining the setting value are obtained.


2014 ◽  
Vol 960-961 ◽  
pp. 995-999
Author(s):  
Wei Cai ◽  
Lin Sun ◽  
Hua Ren Wu

This paper establishes a simulation model of a simplified power system with transformer differential protection based on an embedded Matlab function block. The differential protection consists of percentage restraint differential protection, second harmonic restraint, differential current instantaneous trip protection and over-excitation protection. The model is able to correctly simulate the transformer’s inrush current and internal and external faults. The results from the simulation show that the circuit breaker correctly operates for a transformer internal fault and provides a good braking effect for an external fault. In addition, the protection model is able to identify the inrush current of the transformer and avoid a protection mis-trip event.


2013 ◽  
Vol 457-458 ◽  
pp. 661-666
Author(s):  
Bin Rao ◽  
Qing Yuan Zou ◽  
Ting Jian Zhong ◽  
Qing Ping Liu

because of the existence of non-linear loads,they will be inpouring a lot of harmonic current to the power system,in order to restrain harmonic,we have to take relevant measures to restrain. This paper introduces three measures of harmonic restraint firstly, expounds the active power filter, and then it analyses the work principle and mathematical model of shunt active power filter , building three-phase shunt active power filter simulation model,; At last, using MATLAB simulation experiment ,the result shows that the shunt active power filter of harmonic detection algorithm and the control strategy are correct and effective , and also it has the important significance to the power system harmonic restraint.