poloidal rotation
Recently Published Documents


TOTAL DOCUMENTS

104
(FIVE YEARS 1)

H-INDEX

23
(FIVE YEARS 0)

2021 ◽  
Vol 92 (4) ◽  
pp. 043518
Author(s):  
C. Chrystal ◽  
S. R. Haskey ◽  
K. H. Burrell ◽  
B. A. Grierson ◽  
C. S. Collins

Atoms ◽  
2019 ◽  
Vol 7 (3) ◽  
pp. 93
Author(s):  
Gaurav Shukla ◽  
Malay B. Chowdhuri ◽  
Kajal Shah ◽  
Nandini Yadava ◽  
Ranjana Manchanda ◽  
...  

The impurity ion poloidal rotation and ion temperature from the Aditya-U tokamak plasma have been measured using a high-resolution spectroscopic diagnostic. It comprises of a high resolution, 1 m, f/8.7, Czerny-Turner configuration spectrometer along with charge coupled device (CCD) detector. The system monitors the spectral line emission of C2+ impurity ions at 464.74 nm from the top port of the Aditya-U vacuum vessel with the lines of sight covering the plasma minor radius from r = 11.55 cm to 21.55 cm. The impurity ion poloidal rotation velocity and temperature have been estimated using the Doppler shift and Doppler broadening of the spectral lines respectively. The maximum poloidal rotation at a radial location of 21.55 cm in the edge of the plasma during the plasma current flat top was observed to be ~4 km/s for the analyzed discharges and the ion temperatures measured in the edge were in the range of 32–40 eV.


AIP Advances ◽  
2017 ◽  
Vol 7 (10) ◽  
pp. 105021
Author(s):  
Qing Zhou ◽  
Xinliang Xu ◽  
Jie Wen ◽  
Lin Nie ◽  
Changjian Tang ◽  
...  

2017 ◽  
Vol 24 (5) ◽  
pp. 052510 ◽  
Author(s):  
Baoyi Xie ◽  
Wenfeng Guo ◽  
Nong Xiang

Nukleonika ◽  
2016 ◽  
Vol 61 (4) ◽  
pp. 443-451
Author(s):  
Matěj Tomeš ◽  
Vladimír Weinzettl ◽  
Tiago Pereira ◽  
Martin Imríšek ◽  
Jakub Seidl

Abstract A high-resolution spectroscopic system for the measurements of the CIII triplet at 465 nm was installed at the COMPASS tokamak. The Doppler broadening and shift of the measured spectral lines are used to calculate the edge ion temperature and poloidal plasma rotation. At first, the spectroscopic system based on two-grating spectrometer and the calibration procedure is described. The signal processing including detection and removal of spiky features in the signal caused by hard X-rays based on the difference in the behaviour of Savitzky-Golay and median filters is explained. The detection and position estimation of individual spectral lines based on the continuous wavelet transform is shown. The method of fitting of Gaussians using the orthogonal distance regression and estimation of the error of estimation of the rotation velocity and ion temperature is described. At the end, conclusions about the performance of the spectroscopic system and its shortcomings based on summary of results calculated from 2033 processed spectral lines measured in 61 shots are drawn and the possible enhancements are suggested.


2016 ◽  
Vol 56 (10) ◽  
pp. 106017 ◽  
Author(s):  
Lu Wang ◽  
Tiliang Wen ◽  
P.H. Diamond

2015 ◽  
Vol 22 (3) ◽  
pp. 033703 ◽  
Author(s):  
Manjit Kaur ◽  
Sayak Bose ◽  
P. K. Chattopadhyay ◽  
Devendra Sharma ◽  
J. Ghosh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document