susceptibility artifacts
Recently Published Documents


TOTAL DOCUMENTS

130
(FIVE YEARS 13)

H-INDEX

25
(FIVE YEARS 0)

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Xiaomeng Gao ◽  
Qianbing Wan ◽  
Qingping Gao

AbstractThis study aimed to investigate the artifacts induced by crowns composed of different materials with prepared teeth and titanium implants. Resin, metal-ceramic, ceramic and zirconia crowns were fabricated and placed onto the prepared teeth on a human cadaver head or titanium implants with prosthesis abutments on a dry human mandible. The samples were scanned on a 1.5 T MRI apparatus, and artifact areas were defined as the signal intensity and signal loss adjacent to the prosthesis and measured by a threshold tool with ImageJ2x. Data were analyzed using SPSS 22.0. Resin, ceramic, zirconia, and precious metal-ceramic crowns barely produced artifacts on the cadaver skull (p > 0.999). By contrast, pure Ti and nonprecious metal-ceramic crowns created significant artifacts (p < 0.001). The average artifacts reduction of double Au-Pt and Ag-Pd metal-ceramic crowns combined with titanium implants and abutments was 79.49 mm2 (p < 0.001) and 74.17 mm2 (p < 0.001) respectively, while artifact areas were increased in double Co-Cr and Ni–Cr metal-ceramic crowns by 150.10 mm2 (p < 0.001) and 175.50 mm2 (p < 0.001) respectively. Zirconia, ceramic and precious metal-ceramic crowns induce less MRI artifacts after tooth preparation while precious metal-ceramic crowns alleviate artifacts in combination with titanium implants.


2021 ◽  
Vol 15 ◽  
Author(s):  
Qing Fu ◽  
Xiang-chuang Kong ◽  
Ding-Xi Liu ◽  
Kun Zhou ◽  
Yi-hao Guo ◽  
...  

Purpose: To qualitatively and quantitatively compare the image quality and diagnostic performance of turbo gradient and spin echo PROPELLER diffusion-weighted imaging (TGSE-PROPELLER-DWI) vs. readout-segmented echo-planar imaging (rs-EPI) in the evaluation of orbital tumors.Materials and Methods: A total of 43 patients with suspected orbital tumors were enrolled to perform the two DWIs with comparable spatial resolution on 3T. The overall image qualities, geometric distortions, susceptibility artifacts, and lesion conspicuities were scored by using a four-point scale (1, poor; 4, excellent). Quantitative measurements, including contrast-to-noise ratios (CNRs), apparent diffusion coefficients (ADCs), geometric distortion rates (GDRs), and lesion sizes, were calculated and compared. The two ADCs for differentiating malignant from benign orbital tumors were evaluated. Wilcoxon signed-rank test, Kappa statistic, and receiver operating characteristics (ROC) curves were used.Results: TGSE-PROPELLER-DWI performed superior in all subjective scores and quantitative GDR evaluation than rs-EPI (p &lt; 0.001), and excellent interobserver agreement was obtained for Kappa value ranging from 0.876 to 1.000. ADClesion of TGSE-PROPELLER-DWI was significantly higher than those of rs-EPI (p &lt; 0.001). Mean ADC of malignant tumors was significantly lower than that of benign tumors both in two DWIs. However, the AUC for differentiating malignant and benign tumors showed no significant difference in the two DWIs (0.860 vs. 0.854, p = 0.7448). Sensitivity and specificity could achieve 92.86% and 72.73% for TGSE-PROPELLER-DWI with a cutoff value of 1.23 × 10–3 mm2/s, and 85.71% and 81.82% for rs-EPI with a cutoff value of 0.99 × 10–3 mm2/s.Conclusion: Compared with rs-EPI, TGSE-PROPELLER-DWI showed minimized geometric distortion and susceptibility artifacts significantly improved the image quality for orbital tumors and achieved comparable diagnostic performance in differentiating malignant and benign orbital tumors.


Tomography ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. 792-800
Author(s):  
Fanny Bourhis-Guizien ◽  
Brieg Dissaux ◽  
Grégoire Boulouis ◽  
Douraied Ben Salem ◽  
Jean-Christophe Gentric ◽  
...  

The aim was to assess the occurrence of magnetic susceptibility artifacts (MSA) following endovascular treatment of intracranial aneurysm by stent using susceptibility weighted imaging (SWI). Imaging and clinical data of 46 patients who underwent stent placement in the case of intracranial aneurysm endovascular treatment (S-Group) were retrospectively analyzed and compared to a control group (C-Group) in which 46 patients had coiling alone. The mean number of MSA was higher in the S-group than in the C-group on postprocedural SWI sequence (8.76, 95%CI [5.76; 11.76] vs. 0.78 [0.32; 1.25], respectively, p < 0.001) with a higher frequency of the appearance of MSA also in the S-group (78.26% vs. 21.74% in the C-group, p < 0.001). In the S-group, in the vascular territory of the treated artery, there was a higher number of MSA than in other vascular territories (mean of 5.18 [3.43; 6.92] vs. 3.08 [1.79; 4.36], p = 0.001). An odds ratio (OR) of 20.98 [5.24; 83.95] suggested a higher proportion of onset of MSA in the S-group than in the C-group (p < 0.001). The appearance of MSA after a treatment by stenting for intracranial aneurysm in patients under antiplatelet therapy was common, particularly in the treated artery territory.


2021 ◽  
Vol 15 ◽  
Author(s):  
Xinyuan Miao ◽  
Adrian G. Paez ◽  
Suraj Rajan ◽  
Di Cao ◽  
Dapeng Liu ◽  
...  

Olfaction is a fundamental sense that plays a vital role in daily life in humans, and can be altered in neuropsychiatric and neurodegenerative diseases. Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) using conventional echo-planar-imaging (EPI) based sequences can be challenging in brain regions important for olfactory processing, such as the olfactory bulb (OB) and orbitofrontal cortex, mainly due to the signal dropout and distortion artifacts caused by large susceptibility effects from the sinonasal cavity and temporal bone. To date, few studies have demonstrated successful fMRI in the OB in humans. T2-prepared (T2prep) BOLD fMRI is an alternative approach developed especially for performing fMRI in regions affected by large susceptibility artifacts. The purpose of this technical study is to evaluate T2prep BOLD fMRI for olfactory functional experiments in humans. Olfactory fMRI scans were performed on 7T in 14 healthy participants. T2prep BOLD showed greater sensitivity than GRE EPI BOLD in the OB, orbitofrontal cortex and the temporal pole. Functional activation was detected using T2prep BOLD in the OB and associated olfactory regions. Habituation effects and a bi-phasic pattern of fMRI signal changes during olfactory stimulation were observed in all regions. Both positively and negatively activated regions were observed during olfactory stimulation. These signal characteristics are generally consistent with literature and showed a good intra-subject reproducibility comparable to previous human BOLD fMRI studies. In conclusion, the methodology demonstrated in this study holds promise for future olfactory fMRI studies in the OB and other brain regions that suffer from large susceptibility artifacts.


2021 ◽  
Vol 21 (3) ◽  
pp. 1-16
Author(s):  
Somanka Maiti ◽  
Ashish Kumar ◽  
Smriti Jain ◽  
Gaurav Bhatnagar

In this article, a blockwise regression-based image inpainting framework is proposed. The core idea is to fill the unknown region in two stages: Extrapolate the edges to the unknown region and then fill the unknown pixels values in each sub-region demarcated by the extended edges. Canny edge detection and linear edge extension are used to respectively identify and extend edges to the unknown region followed by regression within each sub-region to predict the unknown pixel values. Two different regression models based on K-nearest neighbours and support vectors machine are used to predict the unknown pixel values. The proposed framework has the advantage of inpainting without requiring prior training on any image dataset. The extensive experiments on different images with contrasting distortions demonstrate the robustness of the proposed framework and a detailed comparative analysis shows that the proposed technique outperforms existing state-of-the-art image inpainting methods. Finally, the proposed techniques are applied to MRI images suffering from susceptibility artifacts to illustrate the practical usage of the proposed work.


2021 ◽  
Vol 77 ◽  
pp. 14-20
Author(s):  
Burcu Basar ◽  
Merdim Sonmez ◽  
Dursun Korel Yildirim ◽  
Ram Paul ◽  
Daniel A. Herzka ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2314
Author(s):  
Soan T. M. Duong ◽  
Son Lam Phung ◽  
Abdesselam Bouzerdoum ◽  
Sui Paul Ang ◽  
Mark M. Schira

Echo planar imaging (EPI), a fast magnetic resonance imaging technique, is a powerful tool in functional neuroimaging studies. However, susceptibility artifacts, which cause misinterpretations of brain functions, are unavoidable distortions in EPI. This paper proposes an end-to-end deep learning framework, named TS-Net, for susceptibility artifact correction (SAC) in a pair of 3D EPI images with reversed phase-encoding directions. The proposed TS-Net comprises a deep convolutional network to predict a displacement field in three dimensions to overcome the limitation of existing methods, which only estimate the displacement field along the dominant-distortion direction. In the training phase, anatomical T1-weighted images are leveraged to regularize the correction, but they are not required during the inference phase to make TS-Net more flexible for general use. The experimental results show that TS-Net achieves favorable accuracy and speed trade-off when compared with the state-of-the-art SAC methods, i.e., TOPUP, TISAC, and S-Net. The fast inference speed (less than a second) of TS-Net makes real-time SAC during EPI image acquisition feasible and accelerates the medical image-processing pipelines.


2021 ◽  
Vol 2021 ◽  
pp. 1-5
Author(s):  
Michele Gaeta ◽  
Giuseppe Cicero ◽  
Luca Fiorillo ◽  
Sergio Vinci ◽  
Alfredo Blandino ◽  
...  

Giant cell tumor of the tendon sheath is a tumor, which affects mainly the hands of people aged 30 to 50 years with a female prevalence. Magnetic resonance imaging (MRI) is essential for diagnosis and treatment planning. The aim of this study is to evaluate the efficacy of multiecho gradient-echoes (MeGE) sequence in detecting hemosiderin which is the hallmark of this tumor. MRIs were performed in a sample of 11 patients with a mean age of 45. With the proposed protocol, all readers were able to detect the susceptibility artifacts due to the presence of hemosiderin. MeGE sequence allows to highlight the presence of hemosiderin, and the use of 3 echo times (ET) (8, 16, and 24 ms) is suggested.


Sign in / Sign up

Export Citation Format

Share Document