digital filter design
Recently Published Documents


TOTAL DOCUMENTS

350
(FIVE YEARS 5)

H-INDEX

22
(FIVE YEARS 0)

Author(s):  
Rizki Aulia Rachman ◽  
I Dewa Gede Hari Wisana ◽  
Priyambada Cahya Nugraha

Measurement of biosignals such as electrocardiograph has the interpretation of noise from other signals. The noise can interfere with the measurement of the heart signal and make the measurement inaccurate, so the purpose of this study is to make a 6-Lead Electrocardiogram module with an Arduino-Based Digital Filter. By using a digital filter. The contribution of this research is the use of digital filters to eliminate noise in electrocardiograph signals. This research uses Infinite Impulse Filter digital filters such as Butterworth, Chebyshev I, Chebyshev II, and Elliptic in order 2, 4, 6, 8, and 10. The study was conducted by providing input from the Function Generator on Arduino which has been applied digital filters with Frequency with 0.5Hz – 100Hz cut-off. The instrument is compared with a factory electrocardiograph. Filter measurements using 460 input data. Butterworth filter with the greatest emphasis on order 8 frequency 0.5Hz produces an emphasis of -5.74298158 dB and a frequency of 100Hz produces an emphasis of -5.93529424 dB. The Chebyshev I filter has the greatest emphasis on order 6 frequency 0.5Hz producing an emphasis of -3.27104076 dB and on order 8 frequency 100Hz producing an emphasis of -5.08730424 dB. Chebyshev II filter the biggest emphasis on the order of frequency 0.5Hz produces a suppression of -44,66011104 dB and 80Hz frequency produces a suppression of -37,3653957 dB. Elliptic filters the greatest emphasis on order 6 frequency 0.5Hz produces an emphasis on -1.55429354 dB and 100Hz frequency on order 8 produces an emphasis on -2.2849115 dB. The results showed that what was appropriate with the cut-off frequency was the Butterworth order 8 filter which was suitable for the application of the Electrocardiograph signal filter because it had bandwidth that suppressed the signal outside the cut-off frequency. The results of this study can be implemented on a 6-Lead ECG module to eliminate noise or interference when tapping ECG signals.


Electronics ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 213
Author(s):  
Hyunmin Park ◽  
Hyungil Chae ◽  
Jintae Kim

This paper presents an optimal digital filtering technique to enhance the resolution of incremental delta-sigma modulators (incremental DSMs, IDSMs) using a low-power passive integrator. We first describe a link between a passive integrator and its impact on the output of the IDSM. We then show that the optimal digital filter design can be cast as a convex optimization problem, which can be efficiently solved. As a test vehicle of the proposed technique, we use a behavioral 2nd-order IDSM model that captures critical non-idealities of the integrator, such as gain compression and output saturation. The effectiveness of the presented technique is verified using extensive simulations. The result shows that the presented filtering technique improves signal-to-noise and distortion ratio (SNDR) by 15 dB–20 dB, achieving SNDR over 90 dB when the oversampling ratio (OSR) = 256, and this corresponds to best-in-class performance when compared to previously published DSM designs using passive integrators.


2020 ◽  
Author(s):  
Constantinos Panayiotou ◽  
Yu Song ◽  
Venkatraman Atti ◽  
Andreas Spanias

2020 ◽  
Vol 1569 ◽  
pp. 032071
Author(s):  
Diana Rahmawati ◽  
Haryanto ◽  
Fahrus Sakariya ◽  
Heri Setiawan

Sign in / Sign up

Export Citation Format

Share Document