red cell volume
Recently Published Documents


TOTAL DOCUMENTS

314
(FIVE YEARS 6)

H-INDEX

38
(FIVE YEARS 0)

Surgery Today ◽  
2021 ◽  
Author(s):  
Chao Dang ◽  
Min Wang ◽  
Tingting Qin ◽  
Renyi Qin

Abstract Background and purpose A new noninvasive biomarker is being sought to predict the prognosis of patients with pancreatic cancer. Red-cell volume distribution width (RDW), a descriptive parameter for erythrocyte variation, has been shown to have prognostic value for some tumor types. Our purpose was to assess the RDW value to predict the prognosis of patients with pancreatic cancer. Methods The subjects of this retrospective study were 792 patients who underwent radical surgery for pancreatic cancer, divided into high-RDW and low-RDW groups based on receiver operating characteristic (ROC) curve analysis (15.6%). The controlling nutritional status (CONUT) score was used to assess preoperative nutritional status. Statistical analysis was conducted to investigate the differences between the high and low RDW groups, and to explore the possibility of the RDW being used as prognostic predictor for patients with pancreatic cancer. Results The immune-nutritional status was worse in the high-RDW group than in the low-RDW group. The high-RDW group patients also had a poorer prognosis. Risk factor analysis showed that the RDW could be an independent risk factor for pancreatic cancer. Conclusions The RDW is associated with immune-nutritional status in pancreatic cancer patients and can be used as an independent prognostic factor for their postoperative survival.


2021 ◽  
Vol 5 (12) ◽  
pp. 2586-2592
Author(s):  
Stacey Uter ◽  
Hyun Hyung An ◽  
Grace E. Linder ◽  
Stephan Kadauke ◽  
Deborah Sesok-Pizzini ◽  
...  

Abstract The COVID-19 pandemic has created major disruptions in health care delivery, including a severe blood shortage. The inventory of Rh and K antigen–negative red cell units recommended for patients with hemoglobinopathies became alarmingly low and continues to be strained. Because patients with sickle cell disease requiring chronic red cell exchange (RCE) incur a large demand for red cell units, we hypothesized that implementation of 2 measures could reduce blood use. First, obtaining the pretransfusion hemoglobin S (HbS) results by procedure start time would facilitate calculation of exact red cell volume needed to achieve the desired post-RCE HbS. Second, as a short-term conservation method, we identified patients for whom increasing the targeted end procedure hematocrit up to 5 percentage points higher than the pretransfusion level (no higher than 36%) was not medically contraindicated. The goal was to enhance suppression of endogenous erythropoiesis and thereby reduce the red cell unit number needed to maintain the same target HbS%. These 2 measures resulted in an 18% reduction of red cell units transfused to 50 patients undergoing chronic RCE during the first 6 months of the COVID-19 pandemic. Despite reduction of blood use, pretransfusion HbS% target goals were maintained and net iron accumulation was low. Both strategies can help alleviate a shortage of Rh and K antigen–negative red cells, and, more generally, transfusing red cell units based on precise red cell volume required can optimize patient care and judicious use of blood resources.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Florian Seiler ◽  
Christoph Ahlgrim ◽  
Philipp Birkner ◽  
Nina Wrobel ◽  
Jonathan Rilinger ◽  
...  

Abstract Background In systolic chronic heart failure, a heterogeneous blood volume (BV) regulation can be found with plasma volume expansion in many cases, possibly leading to pseudoanemia. Little is known about the volume status after heart transplantation (HTX). So far, anemia of HTX recipients was solely investigated using hemoglobin-concentration that may be misleading in a clinical context. The objective of the study was whether a difference in plasma volume and red cell volume can be observed in clinically stable heart transplant recipients compared to matched control subjects. Secondary, the aim was to describe anemia in the long-term after HTX based on quantitative data. Methods Blood volume and its constituents red cell volume and plasma volume were quantified using an abbreviated carbon monoxide rebreathing method (aCORM) with focus on its primary measure total hemoglobin mass (Hbmass) and coincidental anemia in 36 (7 women) heart transplant recipients. For comparison, a matched control group of 46 (5 women) healthy subjects was selected. Results Neither Hbmass nor blood volumes were significantly different in HTX patients compared to matched healthy control group subjects. The prevalence of anemia 6.3 ± 4.3 years after transplantation was 19%. Hbmass and red cell volume were significantly lower in anemic HTX patients compared to non-anemic patients while plasma volume was not expanded. Various immunosuppressant regimens did not have an effect on Hbmass, plasma volume or red cell volume. Conclusions There was no difference in blood volumes and Hbmass between HTX patients and control subjects. The pathophysiologic blood volume regulation in chronic heart failure does not seem to be longer active in long-term HTX recipients. However, in the long-term after HTX, anemia occurs in a considerable number of patients as true anemia without a clear association with immunosuppression. Trial registration German registry for clinical studies, DRKS00006078. Registered 09 May 2014, https://www.drks.de/drks_web/navigate.do?navigationId=trial. HTML&TRIAL_ID=DRKS00006078.


2021 ◽  
Author(s):  
Jenifer Gómez-Pastora ◽  
James Kim ◽  
Mitchell Weigand ◽  
Andre F. Palmer ◽  
Mark Yazer ◽  
...  

Abstract Anemia and iron deficiency continue to be the most prevalent nutritional disorders in the world, affecting billions of people in both developed and developing countries. The initial diagnosis of anemia is typically based on several markers, including red blood cell (RBC) count, hematocrit and total hemoglobin. Using modern hematology analyzers, erythrocyte parameters such as mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), etc. are also being used. However, most of these commercially available analyzers pose several disadvantages: they are expensive instruments that require significant bench space and are heavy enough to limit their use to a specific lab and leading to a delay in results, making them less practical as a point-of-care instrument that can be used for swift clinical evaluation. Thus, there is a need for a portable and economical hematology analyzer that can be used at the point of need. In this work, we evaluated the performance of a system referred to as the cell tracking velocimetry (CTV) to measure several hematological parameters from fresh human blood obtained from healthy donors. Our system, based on the paramagnetic behavior that methemoglobin containing RBCs experience when suspended in water after applying a magnetic field, uses a combination of magnets and microfluidics and has the ability to track the movement of thousands of red cells in a short period of time. This allows us to measure not only traditional RBC indices but also novel parameters that are only available for analyzers that assess erythrocytes on a cell by cell basis. As such, we report, for the first time, the use of our CTV as a hematology analyzer that is able to measure red cell volume or MCV, red cell hemoglobin mass or MCH, hemoglobin concentration (MCHC), red cell distribution width (RDW) and the percentage of hypochromic cells, which is an indicator of insufficient marrow iron supply that reflects recent iron reduction. Our initial results indicate that most of the parameters measured with CTV are within the normal range for healthy adults. Only the parameters related to the red cell volume (primarily MCV and RDW) were outside the normal range. We observed significant discrepancies between the MCV measured by our technology (and also by an automated cell counter) and the manual MCV measured through the hematocrit obtained by packed cell volume method, which are attributed to the artifacts of plasma trapping and cell shrinkage. While there may be limitations for measuring MCV, this device offers a novel point of care instrument to provide rapid RBC parameters such as iron stores that are otherwise not rapidly available to the clinician. Thus, our CTV is a promising technology with the potential to be employed as an accurate, economical, portable and fast hematology analyzer after applying instrument-specific reference ranges or correction factors.


2021 ◽  
Author(s):  
Christoph Ahlgrim ◽  
Florian Seiler ◽  
Philipp Birkner ◽  
Dawid Leander Staudacher ◽  
Sebastian Grundmann ◽  
...  

2020 ◽  
Vol 26 (10) ◽  
pp. S49
Author(s):  
John E. Strobeck ◽  
Jonathan Feldschuh ◽  
Marc A. Silver ◽  
Wayne L. Miller

2020 ◽  
Vol 41 (10) ◽  
pp. 1106-1107
Author(s):  
Juliette Dinet ◽  
David Tonnelet ◽  
Joseph Le Cloirec ◽  
Stéphanie Becker ◽  
Pierre Bohn

2020 ◽  
Vol 41 (6) ◽  
pp. 589-596
Author(s):  
Gillian Ainslie-McLaren ◽  
Angela Fee ◽  
June McKinstray ◽  
Alison B. Lee ◽  
Alison A. Bolster

Sign in / Sign up

Export Citation Format

Share Document