sinogram restoration
Recently Published Documents


TOTAL DOCUMENTS

56
(FIVE YEARS 0)

H-INDEX

10
(FIVE YEARS 0)

2020 ◽  
Vol 20 ◽  
pp. 100350
Author(s):  
Hwisong Ri ◽  
Jongchol Kim ◽  
Muchol Lee ◽  
Hyok Hwang ◽  
Jonghyok Pak

2016 ◽  
Vol 1 ◽  
Author(s):  
Catur Edi Widodo

In some cases the number of projections in a set of tomography data is limited. This can be seen from their sinogram. If this kind of data is reconstructed, the image produced will be deteroited. In order to overcome this problem an algorithm for restoring the incomplete sinogram  has been developed in previous work. In that work the developed algorithm was tested using ideal data from Shepp-Logan panthom. In this paper the same algorithm is applied to restore incomplete and  noisy data in ultrasound  tomography. The phantom used in this study is a concrete cylinder with a diameter of 10.62 cm. Inside  cylinder there are 6 holes with a diameter of 2 cm each. These holes were filled with various materials. The phantom were scanned in ultrasound tomography scheme and the resulted sinogram then reconstructed with and without sinogram restoration. Using contrast to noise ratio (<em>CNR</em>) indicator the reconstructed image with sinogram restoration is better than that without sinogram restoration.


2016 ◽  
Vol 1 (1) ◽  
Author(s):  
Catur Edi Widodo

In some cases the number of projections in a set of tomography data is limited. This can be seen from their sinogram. If this kind of data is reconstructed, the image produced will be deteroited. In order to overcome this problem an algorithm for restoring the incomplete sinogram  has been developed in previous work. In that work the developed algorithm was tested using ideal data from Shepp-Logan panthom. In this paper the same algorithm is applied to restore incomplete and  noisy data in ultrasound  tomography. The phantom used in this study is a concrete cylinder with a diameter of 10.62 cm. Inside  cylinder there are 6 holes with a diameter of 2 cm each. These holes were filled with various materials. The phantom were scanned in ultrasound tomography scheme and the resulted sinogram then reconstructed with and without sinogram restoration. Using contrast to noise ratio (<em>CNR</em>) indicator the reconstructed image with sinogram restoration is better than that without sinogram restoration.


Author(s):  
Louis Frédérique ◽  
Benoit Recur ◽  
Sylvain Genot ◽  
Jean-Philippe Domenger ◽  
Pascal Desbarats

Sign in / Sign up

Export Citation Format

Share Document