anesthetic machine
Recently Published Documents


TOTAL DOCUMENTS

45
(FIVE YEARS 2)

H-INDEX

6
(FIVE YEARS 0)

2020 ◽  
Vol 7 ◽  
Author(s):  
Jose I. Redondo ◽  
Luis Domenech ◽  
Cristina Mateu ◽  
Alfon Bañeres ◽  
Amalia Martínez ◽  
...  

The objective of this retrospective study was to review the results of a 4-year audit performed on anesthetic machines and vaporizers used in veterinary clinics in Spain and Portugal. Data was collected between July 2016 and April 2020. Inspections were carried out by a team of seven veterinarians, using a human-modified system of checks that was adapted to a veterinary practice. The evaluation of each item was noted as “correct” or “incorrect”. The vaporizers' performance was evaluated using a self-calibrating gas analyzer. The vaporizer was classified as “correct” or “incorrect” when the vaporization error was less than or equal to, or more than 20%, respectively. The anesthetic machine was classified as “conforming” if all its components were noted as “correct” and no leaks were detected, or as “non-conforming” if any of the components was noted as “incorrect” or if a leak was detected. If the inspector was able to repair on-site the item malfunctions detected and the machine was fit for use, they issued a final report as “conforming.” On the contrary, if such malfunctions persisted, the final report was “non-conforming,” and a recommendation to remove the machine from service until its final repair was provided. To perform statistical analysis, each inspected item was used as predictor, classification and regression trees were built, and a random forest analysis was performed. A total of 2,001 anesthetic machines and 2,309 vaporizers were studied. After inspection, 42.7 and 26.4% of the machines were non-conforming and conforming, respectively, whereas 30.9% could be repaired in situ. A total of 27.1% of the isoflurane vaporizers and 35.9% of the sevoflurane vaporizers were incorrect. Machine learning techniques showed that the most important variables in the classification of the anesthetic machines as conforming or non-conforming were mostly the scavenger system and the canister, followed some way behind by the APL valve, source of oxygen, reservoir bag, vaporizer, and connections.


2015 ◽  
Vol 120 (6) ◽  
pp. 1264-1270 ◽  
Author(s):  
Roger J. Eltringham ◽  
Robert C. Neighbour

2013 ◽  
Vol 119 (5) ◽  
pp. 1023-1030 ◽  
Author(s):  
Christine M. Ball

Abstract Next year marks the 100th anniversary of the founding of the Foregger Company, an important manufacturer of anesthetic equipment in the first half of the 20th century. Founded by Richard von Foregger in a barn in Long Island, New York in 1914, the Foregger Company developed equipment in collaboration with anesthesiologists. Their first product was the Gwathmey machine, built around the rudimentary flowmeter designed by the anesthesiologist, James Tayloe Gwathmey. This machine was the cornerstone of future anesthetic machine development. As the company grew, von Foregger formed other liaisons, joining forces with Ralph Waters to create the Waters to-and-fro canister for carbon dioxide absorption, and with Arthur Guedel, a variety of nontraumatic airways. The combined creativity of these three men ultimately led to the Foregger Midget. This portable machine extended the reach of the Foregger Company well beyond the shores of America, as far away as the isolated west coast of Australia.


2012 ◽  
Vol 24 (3) ◽  
pp. 258-259
Author(s):  
Hyun Ju Jung ◽  
Jong Bun Kim ◽  
Kyong Shil Im ◽  
Sung Ah Cho ◽  
Jae Myeong Lee