reduced scattering coefficient
Recently Published Documents


TOTAL DOCUMENTS

39
(FIVE YEARS 8)

H-INDEX

9
(FIVE YEARS 0)

Author(s):  
Shaobo Wang ◽  
Yangyang Liu ◽  
Yubing Liu ◽  
Zhiyu Qian ◽  
Zaoqin Chen

Intracranial hypertension is a serious threat to the health of neurosurgical patients. At present, there is a lack of a safe and effective technology to monitor intracranial pressure (ICP) accurately and nondestructively. In this paper, based on near infrared technology, the continuous nondestructive monitoring of ICP change caused by brain edema was studied. The rat brain edema models were constructed by lipopolysaccharide. The ICP monitor and the self-made near infrared tissue parameter measuring instrument were used to monitor the invasive intracranial pressure and the reduced scattering coefficient of brain tissue during the brain edema development. The results showed that there was a negative correlation between the reduced scattering coefficient (690[Formula: see text]nm and 834[Formula: see text]nm) and ICP, and then the mathematical model was established. The experimental results promoted the development of nondestructive ICP monitoring based on near infrared technology.


2021 ◽  
Vol 15 (9) ◽  
pp. 4483-4500
Author(s):  
Christophe Perron ◽  
Christian Katlein ◽  
Simon Lambert-Girard ◽  
Edouard Leymarie ◽  
Louis-Philippe Guinard ◽  
...  

Abstract. Detailed characterization of the spatially and temporally varying inherent optical properties (IOPs) of sea ice is necessary to better predict energy and mass balances, as well as ice-associated primary production. Here we present the development of an active optical probe to measure IOPs of a small volume of sea ice (dm3) in situ and non-destructively. The probe is derived from the diffuse reflectance method used to measure the IOPs of human tissues. The instrument emits light into the ice by the use of an optical fibre. Backscattered light is measured at multiple distances away from the source using several receiving fibres. Comparison to a Monte Carlo simulated lookup table allows, in theory, retrieval of the absorption coefficient, the reduced scattering coefficient and a phase function similarity parameter γ, introduced by Bevilacqua and Depeursinge (1999). γ depends on the two first moments of the Legendre polynomials, allowing the analysis of the backscattered light not satisfying the diffusion regime. The depth reached into the medium by detected photons was estimated using Monte Carlo simulations: the maximum depth reached by 95 % of the detected photons was between 40±2 and 270±20 mm depending on the source–detector distance and on the ice scattering properties. The magnitude of the instrument validation error on the reduced scattering coefficient ranged from 0.07 % for the most scattering medium to 35 % for the less scattering medium over the 2 orders of magnitude we validated. Fixing the absorption coefficient and γ, which proved difficult to measure, vertical profiles of the reduced scattering coefficient were obtained with decimetre resolution on first-year Arctic interior sea ice on Baffin Island in early spring 2019. We measured values of up to 7.1 m−1 for the uppermost layer of interior ice and down to 0.15±0.05 m−1 for the bottommost layer. These values are in the range of polar interior sea ice measurements published by other authors. The inversion of the reduced scattering coefficient at this scale was strongly dependent on the value of γ, highlighting the need to define the higher moments of the phase function. This newly developed probe provides a fast and reliable means for measurement of scattering in sea ice.


2021 ◽  
Author(s):  
Christophe Perron ◽  
Christian Katlein ◽  
Simon Lambert-Girard ◽  
Edouard Leymarie ◽  
Louis-Philippe Guinard ◽  
...  

Abstract. Detailed characterization of the spatially and temporally varying inherent optical properties (IOPs) of sea ice is necessary to better predict energy and mass balances, as well as ice-associated primary production. Here we present the development of an active optical probe to measure IOPs of a small volume of sea ice (dm3) in situ and non-destructively. The probe is derived from the diffuse reflectance method used to measure the IOPs of human tissues. The instrument emits light into the ice by the use of optical fibre. Backscattered light is measured at multiple distances away from the source using several receiving fibres. Comparison to a Monte Carlo simulated lookup table allows to retrieve the absorption coefficient, the reduced scattering coefficient and a phase function similarity parameter γ, introduced by Bevilacqua and Depeursinge (1999), depending on the two first moments of the Legendre polynomials, allowing to analyze the backscattered light not satisfying the diffusion regime. Monte Carlo simulations showed that the depth cumulating 95% of the signal is between 40±2 mm and 270±20 mm depending on the source-detector distance and on the ice scattering properties. The magnitude of the instrument validation error on the reduced scattering coefficient ranged from 0.07% for the most scattering medium to 35% for the less scattering medium over the two orders of magnitude we validated. Vertical profiles of the reduced scattering coefficient were obtained with decimeter resolution on first-year Arctic interior sea ice on Baffin Island in early spring 2019. We measured values of up to 7.1 m−1 for the uppermost layer of interior ice and down to 0.15±0.05 m−1 for the bottommost layer. These values are in the range of polar interior sea ice measurements published by other authors. The inversion of the reduced scattering coefficient at this scale was strongly dependent of γ, highlighting the need to define the higher moments of the phase function. This novel developed probe provides a fast and reliable means for measurement of scattering into sea ice.


2021 ◽  
Vol 93 (7) ◽  
pp. 3386-3392
Author(s):  
Sara Mosca ◽  
Priyanka Dey ◽  
Marzieh Salimi ◽  
Benjamin Gardner ◽  
Francesca Palombo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document