scholarly journals Measurement of initial magnetization curve based on constant magnetic field excited by permanent magnet

2016 ◽  
Vol 65 (14) ◽  
pp. 148101
Author(s):  
Deng Dong-Ge ◽  
Wu Xin-Jun ◽  
Zuo Su
Nature ◽  
1938 ◽  
Vol 142 (3587) ◽  
pp. 209-209 ◽  
Author(s):  
D. A. OLIVER ◽  
J. W. SHEDDEN

Author(s):  
Jianqi Li ◽  
Yu Zhou ◽  
Jianying Li

This paper presented a novel analytical method for calculating magnetic field in the slotted air gap of spoke-type permanent-magnet machines using conformal mapping. Firstly, flux density without slots and complex relative air-gap permeance of slotted air gap are derived from conformal transformation separately. Secondly, they are combined in order to obtain normalized flux density taking account into the slots effect. The finite element (FE) results confirmed the validity of the analytical method for predicting magnetic field and back electromotive force (BEMF) in the slotted air gap of spoke-type permanent-magnet machines. In comparison with FE result, the analytical solution yields higher peak value of cogging torque.


2006 ◽  
Vol 126 (12) ◽  
pp. 1722-1729 ◽  
Author(s):  
Akeshi Takahashi ◽  
Haruo Koharagi ◽  
Satoshi Kikuchi ◽  
Kazumasa Ide ◽  
Kazuo Shima

Author(s):  
Zhi Zeng ◽  
Yongfu Zhou

Background: Detection technology is a product development technique that serves as a basis for quality assurance. As electric energy meters (EEMs) are measurement instruments whose use is mandatory in several nations, their accuracy, which directly depends on their reliability and proper functioning, is paramount. In this study, to eliminate electromagnetic interference, a device is developed for testing a set of EEMs under a constant magnetic field interference. The detection device can simultaneously test 6 electric meters; moreover, in the future, it will be able to measure the influence of magnetic field strength on the measurement accuracy of EEMs, thereby improving the production efficiency of electric meter manufacturers. Methods: In this study, we first design a 3D model of the detection device for a single meter component; then, we establish a network, which includes a control system, and perform the planning of the path of a block that generates a constant magnetic field. Finally, we control the three-axis motion and rotation of the block using a PLC to implement detection for the five sides of the EEM. Results & Discussion: The proposed device can accurately determine whether an EEM can adequately function, within the error range prescribed by a national standard, under electromagnetic interference; this can enable reliable, automatic testing and fault detection for EEMs. Experiments show that our device can decrease the labor cost for EEM manufacturers.


Sign in / Sign up

Export Citation Format

Share Document