scholarly journals Adaptive GPC Structures for Temperature and Relative Humidity Control of a Nonlinear Passive Air Conditioning Unit

Author(s):  
Rousseau Tawegoum ◽  
Riad Riadi ◽  
Ahmed Rachid ◽  
Gerard Chasseriaux
2016 ◽  
Vol 9 ◽  
pp. 10007 ◽  
Author(s):  
Vasileios Mantikos ◽  
Steven Ackerley ◽  
Andrew Kirkham ◽  
Aikaterini Tsiampousi ◽  
David M.G. Taborda ◽  
...  

Author(s):  
Eny Nor Syahira Mohamad Hashim ◽  
◽  
Norhafizah Salleh ◽  
Noor Azlina Abdul Hamid ◽  
◽  
...  

This paper proposes a cooling house system that can promote thermal comfort in buildings without air-conditioning. The cooling panel wall forms a part of an Integrated Building System (IBS), and is essentially made of tubes filled with either water or glycerin as the coolant. Target strength for the panel wall was designed based on the Malaysian Standard (MS) while the building ventilation system followed the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) standard. The results are reported based on indoor and outdoor temperature difference together with relative humidity to identify the best performing house model and also coolant. The outcome of this research is expected to add value to design concepts with a better promotion of air flow and circulation in the building, without over-usage of natural resources and higher building cost to achieve the same objective.


2016 ◽  
Author(s):  
Michael G. Bowler ◽  
David R. Bowler ◽  
Matthew W. Bowler

AbstractThe humidity surrounding a sample is an important variable in scientific experiments. Biological samples in particular require not just a humid atmosphere but often a relative humidity (RH) that is in equilibrium with a stabilizing solution required to maintain the sample in the same state during measurements. The controlled dehydration of macromolecular crystals can lead to significant increases in crystal order, which often leads to higher diffraction quality. Devices that can accurately control the humidity surrounding crystals on a beamline have led to this technique being increasingly adopted, as experiments become easier and more reproducible. Matching the relative humidity to the mother liquor is the first step to allow the stable mounting of a crystal. In previous work, we measured the equilibrium relative humidity for a range of concentrations of the most commonly used precipitants and showed how this related to Raoult’s law for the equilibrium vapour pressure of water above a solution. However, a discrepancy between measured values and those predicted by theory could not be explained. Here, we have used a more precise humidity control device to determine equilibrium relative humidity points. The new results are in agreement with Raoult’s law. We also present a simple argument in statistical mechanics demonstrating that the saturated vapour pressure of a solvent is proportional to its mole fraction in an ideal solution: Raoult’s Law. The same argument can be extended to the case where solvent and solute molecules are of different size, as is the case with polymers. The results provide a framework for the correct maintenance of the RH surrounding samples.SynopsisThe equilibrium relative humidity values for a number of the most commonly used precipitants in biological macromolecule crystallisation have been measured using a new humidity control device. A simple argument in statistical mechanics demonstrates that the saturated vapour pressure of a solvent is proportional to its mole fraction in an ideal solution (Raoult’s Law). The same argument can be extended to the case where solvent and solute molecules are of different size.


Energies ◽  
2019 ◽  
Vol 12 (4) ◽  
pp. 620 ◽  
Author(s):  
Joanna Ferdyn-Grygierek ◽  
Krzysztof Grygierek

In museums, poor microclimate conditions, especially large changes in relative humidity and temperature, can lead to serious deterioration of the exhibits. Properly designed heating, ventilation, and air conditioning (HVAC) systems for precise control of the air parameters are required. However, due to the financial restrictions of museums, complex air-conditioning systems are often not feasible. In this study, we tested and propose novel methods to reduce the short- and long-term fluctuations in the relative humidity in exhibition rooms of a Polish museum. The methods only include indoor temperature and ventilation airflow control strategies, without the use of (de)humidification equipment. The analysis is based on simulations using EnergyPlus software. A multi-zone thermal model of the museum building was validated and calibrated with measured data. A full calendar year was simulated for five control cases (including the current method used) and two internal heat gain schedules. The energy demand for heating and cooling for each case was calculated. The combination of temperature control and adequate ventilation using ambient airflow allows for dramatic improvement in the microclimate conditions. The proportion of the year when the instantaneous indoor relative humidity is ±5% from set point decreased from 85% to 20%. A significant effect was obtained over the summer months.