scholarly journals The Influence of Inlet Air Cooling and Afterburning on Gas Turbine Cogeneration Groups Performance

Author(s):  
Ene Barbu ◽  
Valeriu Vilag ◽  
Jeni Popescu ◽  
Bogdan Gherman ◽  
Andreea Petcu ◽  
...  
Keyword(s):  
Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1382
Author(s):  
Obida Zeitoun

Gas turbine inlet air-cooling (TIAC) is an established technology for augmenting gas turbine output and efficiency, especially in hot regions. TIAC using evaporative cooling is suitable for hot, dry regions; however, the cooling is limited by the ambient wet-bulb temperature. This study investigates two-stage evaporative TIAC under the harsh weather of Riyadh city. The two-stage evaporative TIAC system consists of indirect and direct evaporative stages. In the indirect stage, air is precooled using water cooled in a cooling tower. In the direct stage, adiabatic saturation cools the air. This investigation was conducted for the GE 7001EA gas turbine model. Thermoflex software was used to simulate the GE 7001EA gas turbine using different TIAC systems including evaporative, two-stage evaporative, hybrid absorption refrigeration evaporative and hybrid vapor-compression refrigeration evaporative cooling systems. Comparisons of different performance parameters of gas turbines were conducted. The added annual profit and payback period were estimated for different TIAC systems.


Author(s):  
M. Bianchi ◽  
F. Melino ◽  
A. Peretto ◽  
P. R. Spina ◽  
S. Ingistov

In the last years, among all different gas turbine inlet air cooling techniques, an increasing attention to fogging approach is dedicated. The various fogging strategies seem to be a good solution to improve gas turbine or combined cycle produced power with low initial investment cost and less installation downtime. In particular, overspray fogging and interstage injection involve two-phase flow consideration and water evaporation during compression process (also known as wet compression). According to the Author’s knowledge, the field of wet compression is not completely studied and understood. In the present paper, all the principal aspects of wet compression and in particular the influence of injected water droplet diameter and surface temperature, and their effect on gas turbine performance and on the behavior of the axial compressor (change in axial compressor performance map due to the water injection, redistribution of stage load, etc.) are analyzed by using a calculation code, named IN.FO.G.T.E. (INterstage FOgging Gas Turbine Evaluation), developed and validated by the Authors.


Author(s):  
Sanjay ◽  
Onkar Singh ◽  
B. N. Prasad

This paper deals with the thermodynamic performance of complex gas turbine cycles involving inter-cooling, re-heating and regeneration. The performance has been evaluated based on the mathematical modeling of various elements of gas turbine for the real situation. The fuel selected happens to be natural gas and the internal convection / film / transpiration air cooling of turbine bladings have been assumed. The analysis has been applied to the current state-of-the-art gas turbine technology and cycle parameters in four classes: Large industrial, Medium industrial, Aero-derivative and Small industrial. The results conform with the performance of actual gas turbine engines. It has been observed that the plant efficiency is higher at lower inter-cooling (surface), reheating and regeneration yields much higher efficiency and specific power as compared to simple cycle. There exists an optimum overall compression ratio and turbine inlet temperature in all types of complex configuration. The advanced turbine blade materials and coating withstand high blade temperature, yields higher efficiency as compared to lower blade temperature materials.


Author(s):  
Walter W. Shelton ◽  
Robin W. Ames ◽  
Richard A. Dennis ◽  
Charles W. White ◽  
John E. Plunkett ◽  
...  

The U.S. Department of Energy’s (DOE) provides a worldwide leadership role in the development of advanced fossil fuel-based energy conversion technologies, with a focus on electric power generation with carbon capture and storage (CCS). As part of DOE’s Office of Fossil Energy, the National Energy Technology Laboratory (NETL) implements research, development, and demonstration (RD&D) programs that address the challenges of reducing greenhouse gas emissions. To meet these challenges, NETL evaluates advanced power cycles that will maximize system efficiency and performance, while minimizing CO2 emissions and the costs of CCS. NETL’s Hydrogen Turbine Program has sponsored numerous R&D projects in support of Advanced Hydrogen Turbines (AHT). Turbine systems and components targeted for development include combustor technology, materials research, enhanced cooling technology, coatings development, and more. The R&D builds on existing gas turbine technologies and is intended to develop and test the component technologies and subsystems needed to validate the ability to meet the Turbine Program goals. These technologies are key components of AHTs, which enable overall plant efficiency and cost of electricity (COE) improvements relative to an F-frame turbine-based Integrated Gasification Combined Cycle (IGCC) reference plant equipped with carbon capture (today’s state-of-the-art). This work has also provided the basis for estimating future IGCC plant performance based on a Transformational Hydrogen Turbine (THT) with a higher turbine inlet temperature, enhanced material capabilities, reduced air cooling and leakage, and higher pressure ratios than the AHT. IGCC cases from using system-level AHT and THT gas turbine models were developed for comparisons with an F-frame turbine-based IGCC reference case and for an IGCC pathway study. The IGCC pathway is presented in which the reference case (i.e. includes F-frame turbine) is sequentially-modified through the incorporation of advanced technologies. Advanced technologies are considered to be either 2nd Generation or Transformational, if they are anticipated to be ready for demonstration by 2025 and 2030, respectively. The current results included the THT, additional potential transformational technologies related to IGCC plant sections (e.g. air separation, gasification, gas cleanup, carbon capture, NOx reduction) are being considered by NETL and are topics for inclusion in future reports.


2018 ◽  
pp. 39-44
Author(s):  
Богдан Сергійович Портной ◽  
Андрій Миколайович Радченко ◽  
Роман Миколайович Радченко ◽  
Сергій Анатолійович Кантор

The processes of air cooling at the gas turbine unit inlet by absorption lithium-bromide chiller have been analyzed. The computer programs of firms-producers of heat exchangers were used for the gas turbine unit inlet air cooling processes simulation. The absorption lithium-bromide chiller refrigeration capacity reserve (the design heat load excess over the current heat loads) generated at the reduced current heat loads on the air coolers at the gas turbine unit inlet in accordance with the lowered ambient air parameters has been considered. The absorption lithium-bromide chiller refrigeration capacity reserve is expedient to use at increased heat load on the air cooler. To solve this problem the refrigeration capacity required for cooling air at the gas turbine unit inlet has been compared with the excessive absorption lithium-bromide chiller refrigeration capacity exceeding current heat loads during July 2017.The scheme of gas turbine unit inlet air cooling system with using the absorption lithium-bromide chiller refrigeration capacity reserve has been proposed. The proposed air cooling system provides gas turbine unit inlet air precooling in the air cooler booster stage by using the absorption lithium-bromide chiller excessive refrigeration capacity. The absorption chiller excessive refrigeration capacity generated during decreased heat loads on the gas turbine unit inlet air cooler is accumulated in the thermal storage. The results of simulation show the expediency of the gas turbine unit inlet air cooling by using the absorption lithium-bromide chiller refrigeration capacity reserve, which is generated at reduced thermal loads, for the air precooling in the air cooler booster stage. This solution provides the absorption lithium-bromide chiller installed (designed) refrigeration capacity and cost reduction by almost 30%. The solution to increase the efficiency of gas turbine unit inlet air cooling through using the absorption chiller excessive refrigeration potential accumulated in the thermal storage has been proposed.


Sign in / Sign up

Export Citation Format

Share Document