scholarly journals Isoconductivity method to study adhesion of yeast cells to gold electrode

2019 ◽  
Vol 5 (1) ◽  
pp. 40-47 ◽  
Author(s):  
Gabriel A. Ruiz ◽  
Martín L. Zamora ◽  
Carmelo J. Felice

AbstractIn this paper, we used impedance spectroscopy and gold electrodes to detect the presence of yeast cells and monitor the attachment of these cells to the electrodes. We analyzed the effect of conductivity changes of the medium and the attachment on the electrode-electrolyte interface impedance. A three-electrode cell was designed to produce a uniform electric field distribution on the working electrode and to minimize the counter electrode impedance. Moreover, we used a small AC overpotential (10 mV) to keep the system within the linear impedance limits of the electrode-electrolyte interface. This study proposes a new method to differentiate the impedance changes due to the attachment of yeast cells from those due to conductivity changes of the medium. The experiments showed that when the difference between the cell suspension and base solution conductivities is within the experimental error, the impedance changes are only due to the attachment of yeast cells to the electrodes. The experiments also showed a strong dependence (decrease) of the parallel capacity of the electrode electrolyte interface with the yeast cell concentration of suspension. We suggest that this decrease is due to an asymmetrical redistribution of surface charges on both sides of cell, which can be modeled as a biologic capacity connected in series with the double layer capacity of the interface. Our results could help to explain the rate of biofilm formation through the determination of the rate of cell adhesion.

2011 ◽  
Vol 497 ◽  
pp. 87-92 ◽  
Author(s):  
Masaru Hakoda ◽  
Takashi Otaki

This paper reports the separation of cells using a dielectrophoretic (DEP) chromatography device. The device consists of a micro channel and an array of interdigitated microelectrodes on a glass substrate. The sample cells were fed pulse-wise into the carrier flow using a micro-injector. The cells in the sample received a non-uniform electric field made with an electrode array. The direction of DEP motion is towards the higher field when the cell is more polarizable than the medium (positive DEP), while the direction is towards the lower field when the cell is less polarizable than the medium (negative DEP). Therefore, the cell separation depends on the size and dielectric characteristic. The effects of carrier flow rate, frequency, applied voltage, and sweep frequency on the retention time of the sample in the device were examined. In this study, mouse-hybridoma 3-2H3 cells and yeast cells were used as the sample cell. The analytical characteristic of the DEP chromatography device was evaluated according to the difference of retention time by the electric field. As a result, the separation in the cells in the negative DEP using the DEP chromatography was found to be effective. In addition, the effect of the sweep frequency on the difference in the retention time of the mouse hybridoma 3-2H3 cells and the yeast cells was very large. Consequently, the effectiveness of the DEP chromatography device was proven.


2020 ◽  
Vol 63 (9) ◽  
pp. 2921-2929
Author(s):  
Alan H. Shikani ◽  
Elamin M. Elamin ◽  
Andrew C. Miller

Purpose Tracheostomy patients face many adversities including loss of phonation and essential airway functions including air filtering, warming, and humidification. Heat and moisture exchangers (HMEs) facilitate humidification and filtering of inspired air. The Shikani HME (S-HME) is a novel turbulent airflow HME that may be used in-line with the Shikani Speaking Valve (SSV), allowing for uniquely preserved phonation during humidification. The aims of this study were to (a) compare the airflow resistance ( R airflow ) and humidification efficiency of the S-HME and the Mallinckrodt Tracheolife II tracheostomy HME (M-HME) when dry (time zero) and wet (after 24 hr) and (b) determine if in-line application of the S-HME with a tracheostomy speaking valve significantly increases R airflow over a tracheostomy speaking valve alone (whether SSV or Passy Muir Valve [PMV]). Method A prospective observational ex vivo study was conducted using a pneumotachometer lung simulation unit to measure airflow ( Q ) amplitude and R airflow , as indicated by a pressure drop ( P Drop ) across the device (S-HME, M-HME, SSV + S-HME, and PMV). Additionally, P Drop was studied for the S-HME and M-HME when dry at time zero (T 0 ) and after 24 hr of moisture testing (T 24 ) at Q of 0.5, 1, and 1.5 L/s. Results R airflow was significantly less for the S-HME than M-HME (T 0 and T 24 ). R airflow of the SSV + S-HME in series did not significant increase R airflow over the SSV or PMV alone. Moisture loss efficiency trended toward greater efficiency for the S-HME; however, the difference was not statistically significant. Conclusions The turbulent flow S-HME provides heat and moisture exchange with similar or greater efficacy than the widely used laminar airflow M-HME, but with significantly lower resistance. The S-HME also allows the innovative advantage of in-line use with the SSV, hence allowing concurrent humidification and phonation during application, without having to manipulate either device.


2018 ◽  
Vol 934 (4) ◽  
pp. 2-7
Author(s):  
P.A. Medvedev ◽  
M.V. Novgorodskaya

This work contains continued research carried out on improving mathematical models of the Gauss-Krueger projection in accordance with the parameters of any ellipsoid with the removal of points from the axial meridian to l ≤ 6° . In terms of formulae earlier derived by the authors with improved convergence for the calculation of planar rectangular coordinates by geodesic coordinates, the algorithms for determining the convergence of meridians on the plane and the scale of the image are obtained. The improvement of the formulae represented in the form of series in powers of the difference in longitudes was accomplished by separating spherical terms in series and then replacing their approximate sums by exact expressions using the formulae of spherical trigonometry. As in previous works published in this journal [7, 8], determining the sums of the spherical terms was carried out according to the laws of the transverse-cylindrical projection of the sphere on the plane. Theoretical studies are given and formulae are proposed for estimating the observational errors in the results of the derived algorithms. The maximum of observational errors of convergence of meridians and scale, proceeding from the specified accuracy of the determined quantities was established through analytical methods.


2004 ◽  
Vol 82 (8) ◽  
pp. 1294-1303 ◽  
Author(s):  
Vanessa Renée Little ◽  
Keith Vaughan

1-Methylpiperazine was coupled with a series of diazonium salts to afford the 1-methyl-4-[2-aryl-1-diazenyl]piperazines (2), a new series of triazenes, which have been characterized by 1H and 13C NMR spectroscopy, IR spectroscopy, and elemental analysis. Assignment of the chemical shifts to specific protons and carbons in the piperazine ring was facilitated by comparison with the chemical shifts in the model compounds piperazine and 1-methylpiperazine and by a HETCOR experiment with the p-tolyl derivative (2i). A DEPT experiment with 1-methylpiperazine (6) was necessary to distinguish the methyl and methylene groups in 6, and a HETCOR spectrum of 6 enabled the correlation of proton and carbon chemical shifts. Line broadening of the signals from the ring methylene protons is attributed to restricted rotation around the N2-N3 bond of the triazene moiety in 2. The second series of triazenes, the ethyl 4-[2-phenyl-1-diazenyl]-1-piperazinecarboxylates (3), have been prepared by similar diazonium coupling to ethyl 1-piperazinecarboxylate and were similarly characterized. The chemical shifts of the piperazine ring protons are much closer together in series 3 than in series 2, resulting in distortion of the multiplets for these methylenes. It was noticed that the difference between these chemical shifts in 3 exhibited a linear free energy relationship with the Hammett substituent constants for the substituents in the aryl ring. Key words: triazene, piperazine, diazonium coupling, NMR, HETCOR, linear free energy relationship.


Author(s):  
I.V. Frolov ◽  
◽  
V.A. Sergeev ◽  
A.M. Hodakov ◽  
S.A. Zaytsev ◽  
...  

The paper presents the results of studies of changes in the characteristics of LED COB matrices of the GW P9LR31.EM - DURIS S 8 type as part of a LED luminaire when tested under the direct current in a continuous mode and in an electrocycling mode. The arrays consist of eight InGaN/GaN LED dies connected in series, coated with a phosphor. Calculation in the Comsol Multiphtsics environment of the temperature field of the luminaire at the rated operating current and free convection heat transfer showed that the maximum overheating of the matrices does not exceed 46 K, and the difference in their temperatures is 2 K. At the same time, the experimental values of the thermal resistances of the matrices of a real lamp vary from 42 to 58 K/W. Before testing, the I-V characteristics of the matrices differ markedly in the level of leakage current in the voltage range from 14 V to 19 V, and the LEDs in the luminaire matrices have a significant spread in the brightness of emission in the microcurrent mode. The degree of this scatter within each matrix was estimated by measuring the luminescence brightness of each die of the matrix and calculating the coefficient of variation γ. It was found that the coefficient of variation of the emission brightness of the COB matrix dies measured at a current of 100 nA strongly correlates with the leakage current. When testing a luminaire under the direct current, the most significant changes in the electrophysical and optical characteristics of COB matrices are observed in the range of microcurrents: the distribution of the emission brightness of the matrix dies at a current of 100 nA becomes more uniform. The greatest changes in matrix characteristics were observed after the first 700 hours of testing, that is, at the running-in stage. At the same time, no correlation was found between the degree of change in the characteristics of the matrices during tests and their thermal resistances.


Author(s):  
I. S. Fischer ◽  
R. N. Paul

Abstract The input-output displacement relations of two Cardan joints arranged in series on a driveline has been investigated in detail, including the effects of unequal joints angles, the phase angle between the two Cardan joints and also such manufacturing tolerance errors as non-rigth angle link lengths and offset joint axes. A combined Newton-Raphson and Davidson-Fletcher-Powell optimization algorithm using dual-number coordinate-transformation matrices was employed to perform the analysis. An experiment was conducted to validate the results of the analysis. The apparatus consisted of a double-Cardan-joint driveline whose rotations were measured by optical shaft encoders that were sampled by a computer data-acquisition system. The equipment was arranged so that the phase angle between the joints and the offset angles between the shafts at each of the two joints could be readily varied. The “relative phase angle”, the difference between the phase angle of the two joints and the angle between the planes defined by the input and intermediate and the intermediate and output shafts, was found to be the significant factor. If the offset angles at both Cardan joints are equal, the double-Cardan-joint driveline function as a constant-velocity coupling when the magnitude of the relative phase angle is zero. If the offset angles at the two Cardan joints are unequal, a condition prevailing in the important front-wheel-drive automobile steering column, then fluctuation in output velocity for a constant input velocity is minimized although not eliminated for zero relative phase angle.


2011 ◽  
Vol 383-390 ◽  
pp. 1386-1390 ◽  
Author(s):  
Yan Pin Li ◽  
Hai Peng Nan ◽  
Kai Chuang Duan

The author analyzed the working environment of special hydraulic turbine for cooling tower basing on the difference between the special turbine for cooling tower and the conventional power turbine. The former works in series pressure system and the water head determined by the pipeline resistance and the property of circulating water pump of cooling tower. It is the key to transform the cooling tower system successfully and save energy to build up a series special theories which include the specific speed of turbine for cooling tower, the type of turbine, the parameters selection, the design of the flow passage and runner of turbine by effectively transforming the conventional power turbine theory to the special turbine of cooling tower.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3217
Author(s):  
Yun Geng ◽  
Xiaofei Yao ◽  
Jinlong Dong ◽  
Xue Liu ◽  
Yingsan Geng ◽  
...  

The prestrike phenomenon in vacuum circuit breakers (VCBs) is interesting but complicated. Previous studies mainly focus on the prestrike phenomenon in single-break VCBs. However, experimental work on prestrike characteristics of double-break VCBs cannot be found in literature. This paper aims to experimentally determine the probabilistic characteristics of prestrike gaps in a double-break VCB consisting of two commercial vacuum interrupters (VIs) in series under direct current (DC) voltages. As a benchmark, single-break prestrike gaps were measured by short-circuiting one of the VIs in a double break. The experimental results show that the 50% prestrike gap d50 of each VI in a double break, which is calculated with the complementary Weibull distribution, was significantly reduced by 25% to 72.7% compared with that in a single break. Due to the voltage-sharing effect in the double-break VCB, scatters in prestrike gaps of each VI in a double break was smaller than that in a single break. However, without the sharing-voltage effect, d50 of the low-voltage side in the double break was 65% higher than that of the same VI in the single break, which could be caused by the asynchronous property of mechanical actuators, the difference of the inherent prestrike characteristics of each VI and the unequal voltage-sharing ratio of VIs.


VLSI Design ◽  
1998 ◽  
Vol 8 (1-4) ◽  
pp. 325-330
Author(s):  
S. Roy ◽  
A. Asenov ◽  
S. Babiker ◽  
J. R. Barker ◽  
S. P. Beaumont

The microwave performance potential of Si/SiGe pseudomorphic MODFETs are studied, in comparison to state of the art InGaAs pseudomorphic HEMTs. Both devices have equivalent structures corresponding to a physical HEMT used for calibration. We use an RF analysis technique based on transient Monte Carlo simulations to estimate the intrinsic noise figures, the RF figures of merit fT and fmax, and the effect of contact and gate resistances. Both devices exhibit velocity overshoot below the gate region. It is shown that the difference in noise figures and fT values can be mainly attributed to differences in device channel velocity, fmax exhibits a strong dependence on device contact resistance, eroding some of the performance advantage of the pseudomorphic HEMT.


2005 ◽  
Vol 83 (9) ◽  
pp. 1365-1371 ◽  
Author(s):  
Ik-Hwan Um ◽  
Ji-Youn Lee ◽  
Sun-Young Bae ◽  
Erwin Buncel

We report on a nucleophilic study of esters R-C(=X)-Y-Ar in which the electrophilic center has been modified by replacing O by S in the leaving group or carbonyl center: 4-nitrophenyl acetate (1), S-4-nitrophenyl thioacetate (2), 4-nitrophenyl benzoate (3), and O-4-nitrophenyl thionobenzoate (4). The studies include O– and S– nucleophiles as well as α nucleophiles in H2O at 25.0 ± 0.1 °C. The sulfur nucleophile (4-chlorothiophenoxide, 4-ClPhS–) exhibits significant enhanced reactivity for the reactions with thiol and thione esters 2 and 4 compared with their oxygen analogues 1 and 3. On the contrary, the common nucleophile OH– is much less reactive towards 2 and 4 compared with 1 and 3. The effect of changing both the electrophilic center and the nucleofugic center on the reactivity of the other oxygen nucleophiles is not so significant: 4-chlorophenoxide (4-ClPhO–) is four to six times more reactive in the reactions with thiol and thione esters 2 and 4 compared with their oxygen analogues 1 and 3. The α effects exhibited by butan-2,3-dione monoximate (Ox–) and HOO– are strongly dependent on the nature of the electrophilic center of the substrates, indicating that the difference in the ground-state solvation energy cannot be fully responsible for the α effect. Our results clearly emphasize the strong dependence of the α effect on the substrate structure, notably, the nature of the electrophilic center. The impact of change in the nucleofuge (1→2) and the electrophilic center (3→4) on reactivity indicates that α nucleophiles will need to be “purpose built” for decontamination and nucleophilic degradation of specific biocides.Key words: α effect, nucleophilicity, nucleofuge effect, electrophilicity, polarizability.


Sign in / Sign up

Export Citation Format

Share Document