Low-Dose Bath with Volumetric Modulated arc Therapy in Breast Cancer: “Much ado about Nothing?”

2016 ◽  
Vol 102 (4) ◽  
pp. 335-336 ◽  
Author(s):  
Filippo Alongi ◽  
Niccolò Giaj-Levra ◽  
Alba Fiorentino ◽  
Rosario Mazzola ◽  
Sergio Fersino ◽  
...  
2018 ◽  
Vol 13 (1) ◽  
Author(s):  
Pei-Chieh Yu ◽  
Ching-Jung Wu ◽  
Hsin-Hua Nien ◽  
Louis Tak Lui ◽  
Suzun Shaw ◽  
...  

2020 ◽  
Vol 61 (5) ◽  
pp. 747-754
Author(s):  
Yoshiko Doi ◽  
Minoru Nakao ◽  
Hideharu Miura ◽  
Shuichi Ozawa ◽  
Masahiro Kenjo ◽  
...  

ABSTRACT To improve the homogeneity and conformity of the irradiation dose for postoperative breast cancer including regional lymph nodes, we planned Hybrid volumetric-modulated arc therapy (VMAT), which combines conventional tangential field mainly for the chest area and VMAT mainly for the supraclavicular area and marginal zone. In this study, we compared the dosimetric impact between traditional 3D conformal radiotherapy (3DCRT) and Hybrid VMAT and observed toxicities following Hybrid VMAT. A total of 70 patients indicated between October 2016 and December 2017 were included. The prescribed dose was 50 Gy/25 fractions. For the dosimetric impact, 3DCRT and Hybrid VMAT plans were compared in each patient with respect to the dosimetric parameters. Toxicities were followed using the Common Terminology Criteria for Adverse Events version 4.0. The median follow-up duration was 319 days. For the dosimetric impact, the homogeneity index (HI) and conformity index (CI) of PTV were significantly improved in the Hybrid VMAT plan compared with that in the 3DCRT plan (HI, 0.15 ± 0.07 in Hybrid VMAT vs 0.41 ± 0.19 in 3DCRT, P < 0.001; CI, 1.61 ± 0.44 in Hybrid VMAT vs 2.10 ± 0.56 in 3DCRT, P < 0.001). The mean irradiated ipsilateral lung dose was not significantly different in both plans (12.0 ± 2.4 Gy in Hybrid VMAT vs 11.8 ± 2.8 Gy in 3DCRT, P < 0.533). Regarding toxicity, there were no patients who developed ≥grade 3 acute toxicity and ≥grade 2 pneumonitis during the follow-up. Hybrid VMAT for postoperative breast cancer including regional lymph nodes was a reasonable technique that improved the homogeneity and conformity of the irradiation dose to the planning target volume while keeping the irradiation dose to organs at risk to a minimum.


Cancers ◽  
2021 ◽  
Vol 13 (20) ◽  
pp. 5043
Author(s):  
Pei-Yu Hou ◽  
Chen-Hsi Hsieh ◽  
Le-Jung Wu ◽  
Chen-Xiong Hsu ◽  
Deng-Yu Kuo ◽  
...  

Background: For advanced breast cancer with lymph node involvement, adjuvant radiotherapy (RT) with regional nodal irradiation (RNI) has been indicated to reduce cancer recurrence and mortality. However, an extensive RT volume is associated with normal organ exposure, which increases the toxicity and affects patient outcomes. Modern arc RT techniques can improve normal organ sparing compared with conventional techniques. The aim of this study was to explore the optimal technique for left-breast RT with RNI. Methods: We retrospectively reviewed patients receiving RT with RNI for left-breast cancer. We used modern arc RT techniques with either volumetric-modulated arc therapy (VMAT) or helical tomotherapy (HT) with a novel block technique, and compared differences in dosimetry parameters between the two groups. Subgroup analysis of RNI with or without internal mammary node (IMN) volume was also performed. Results: A total of 108 eligible patients were enrolled between 2017 and 2020, of whom 70 received VMAT and 38 received HT. The median RT dose was 55 Gy. No significant differences were found regarding the surgery, RT dose, number of fractions, target volume, and RNI volume between the VMAT and HT groups. VMAT reduced the heart mean dose more than HT (3.82 vs. 5.13 Gy, p < 0.001), as well as the cardiac parameters of V5-V20, whole-lung mean dose, lung parameters of V5-V20, and contralateral-breast and esophagus mean dose. In the subgroup analysis of RNI with IMNs, the advantage of VMAT persisted in protecting the heart, lung, contralateral breast, and esophagus. HT was beneficial for lowering the thyroid mean dose. For RNI without IMN, VMAT improved the low-dose exposure of the heart and lung, but HT was similar to VMAT in terms of heart, whole-lung, and contralateral-breast mean dose. Conclusions: For patients with left-breast cancer receiving adjuvant RT with RNI, VMAT reduced the exposure dose to the heart, lung, contralateral breast, and esophagus compared with HT. VMAT was superior to HT in terms of normal organ sparing in the patients who underwent RNI with IMN irradiation. Considering the reduction in normal organ exposure and potential toxicity, VMAT is the optimal technique for patients receiving RNI when deep inspiration breath-hold is not available.


2021 ◽  
Author(s):  
Tao Sun ◽  
Xiutong Lin ◽  
Guifang Zhang ◽  
Qingtao Qiu ◽  
Chengqiang Li ◽  
...  

Abstract Background: The Halcyon is a new machine from the Varian company. The purpose of this study was to evaluate the dosimetry of the Halcyon in treatment of bilateral breast cancer with volumetric modulated arc therapy. Methods: On CT images of 10 patients with bilateral breast cancer, four Halcyon plans with different setup fields were generated, and dosimetric comparisons using Bonferroni’s multiple comparisons test were conducted among the four plans. Whole and partial arc plans on the Trilogy and the Halcyon, referred to as T-4arc, T-8arc, H-4arc and H-8arc, were designed. The prescription dose was 50 Gy in 2-Gy fractions. All plans were designed with the Eclipse version 15.5 treatment planning system. The dosimetric differences between whole and partial arc plans in the same accelerator were compared using the Mann-Whitney U test. The better Halcyon plan was selected for the further dosimetric comparison of the plan quality and delivery efficiency between the Trilogy and the Halcyon. Results:Halcyon plans with high‐quality megavoltage cone beam CT setup fields increased the Dmean, D2 and V107 of the planning target volume (PTV) and the V5 and Dmean of the heart, left ventricle (LV) and lungs compared with other Halcyon setup plans. The mean dose and low dose volume of the heart, lungs and liver were significantly decreased in T-8arc plans compared to T-4arc plans. In terms of the V5, V20, V30, V40 and Dmean of the heart, the V20, V30, V40 and Dmean of the LV, the V30, V40, Dmax and Dmean of the left anterior descending artery (LAD), and the V5 and V40 of lungs, H-8arc was significantly higher than H-4arc (p<0.05). Compared with the Trilogy’s plans, the Halcyon’s plans reduced the high-dose volume of the heart and LV but increased the mean dose of the heart. For the dose of the LAD and the V20 and V30 of lungs, there was no significant difference between the two accelerators. Compared with the Trilogy, plans on the Halcyon significantly increased the skin dose but also significantly reduced the delivery time. Conclusion: For the Halcyon, the whole-arc plans have more dosimetric advantages than partial-arc plans in bilateral breast cancer radiotherapy. Although the mean dose of the heart and the skin dose are increased, the doses of the cardiac substructure and other OARs are comparable to the Trilogy, and the delivery time is significantly reduced.


2014 ◽  
Vol 45 (2) ◽  
pp. 162
Author(s):  
Krista Bota ◽  
Stewart Gaede ◽  
Scott Karnas ◽  
Eugene Wong ◽  
Wong Eugene ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document