An Electron Microscope Reinforcement Criterion for Carbon Black Masterbatches

1962 ◽  
Vol 35 (1) ◽  
pp. 250-256 ◽  
Author(s):  
Eddie B. Prestridge

Abstract With the advent of wet masterbatching methods, which provide a preliminary dispersion of carbon black in latex, techniques for the microscopic evaluation of the quality of this incorporation proved inadequate. Three reinforcement criteria were developed for such evaluations: dispersion, grinding, and bonding. Using these criteria the performance characteristics of a tread stock made with such masterbatches can be predicted with good reliability. The correlation of reinforcement criteria and the raw Mooney of the masterbatch reveals the striking effect of improved carbon black incorporation on this property. Using this correlation it should be possible to evaluate masterbatch production on a continuous basis.

Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.


Author(s):  
John H. Luft

With information processing devices such as radio telescopes, microscopes or hi-fi systems, the quality of the output often is limited by distortion or noise introduced at the input stage of the device. This analogy can be extended usefully to specimen preparation for the electron microscope; fixation, which initiates the processing sequence, is the single most important step and, unfortunately, is the least well understood. Although there is an abundance of fixation mixtures recommended in the light microscopy literature, osmium tetroxide and glutaraldehyde are favored for electron microscopy. These fixatives react vigorously with proteins at the molecular level. There is clear evidence for the cross-linking of proteins both by osmium tetroxide and glutaraldehyde and cross-linking may be a necessary if not sufficient condition to define fixatives as a class.


Author(s):  
P. Sadhukhan ◽  
J. B. Zimmerman

Rubber stocks, specially tires, are composed of natural rubber and synthetic polymers and also of several compounding ingredients, such as carbon black, silica, zinc oxide etc. These are generally mixed and vulcanized with additional curing agents, mainly organic in nature, to achieve certain “designing properties” including wear, traction, rolling resistance and handling of tires. Considerable importance is, therefore, attached both by the manufacturers and their competitors to be able to extract, identify and characterize various types of fillers and pigments. Several analytical procedures have been in use to extract, preferentially, these fillers and pigments and subsequently identify and characterize them under a transmission electron microscope.Rubber stocks and tire sections are subjected to heat under nitrogen atmosphere to 550°C for one hour and then cooled under nitrogen to remove polymers, leaving behind carbon black, silica and zinc oxide and 650°C to eliminate carbon blacks, leaving only silica and zinc oxide.


2018 ◽  
Vol 34 (6) ◽  
pp. 367-375 ◽  
Author(s):  
Laura D. Seligman ◽  
Erin F. Swedish ◽  
Jason P. Rose ◽  
Jessica M. Baker

Abstract. The current study examined the validity of two self-report measures of social anxiety constructed using social comparative referent points. It was hypothesized that these comparison measures would be both reliable and valid. Results indicated that two different comparative versions – one invoking injunctive norms and another invoking descriptive norms – showed good reliability, excellent internal consistency, and acceptable convergent and discriminant validity. The comparative measures also predicted positive functioning, some aspects of social quality of life, and social anxiety as measured by an independent self-report. These findings suggest that adding a comparative reference point to instructions on social anxiety measures may aid in the assessment of social anxiety.


2021 ◽  
Vol 19 (1) ◽  
Author(s):  
R. Shah ◽  
F. M. Ali ◽  
A. Y. Finlay ◽  
M. S. Salek

Abstract Background A person’s chronic health condition or disability can have a huge impact on the quality of life (QoL) of the whole family, but this important impact is often ignored. This literature review aims to understand the impact of patients' disease on family members across all medical specialities, and appraise existing generic and disease-specific family quality of life (QoL) measures. Methods The databases Medline, EMBASE, CINHAL, ASSIA, PsycINFO and Scopus were searched for original articles in English measuring the impact of health conditions on patients' family members/partner using a valid instrument. Results Of 114 articles screened, 86 met the inclusion criteria. They explored the impact of a relative's disease on 14,661 family members, mostly 'parents' or 'mothers', using 50 different instruments across 18 specialities including neurology, oncology and dermatology, in 33 countries including the USA, China and Australia. These studies revealed a huge impact of patients' illness on family members. An appraisal of family QoL instruments identified 48 instruments, 42 disease/speciality specific and six generic measures. Five of the six generics are aimed at carers of children, people with disability or restricted to chronic disease. The only generic instrument that measures the impact of any condition on family members across all specialities is the Family Reported Outcome Measure (FROM-16). Although most instruments demonstrated good reliability and validity, only 11 reported responsiveness and only one reported the minimal clinically important difference. Conclusions Family members' QoL is greatly impacted by a relative's condition. To support family members, there is a need for a generic tool that offers flexibility and brevity for use in clinical settings across all areas of medicine. FROM-16 could be the tool of choice, provided its robustness is demonstrated with further validation of its psychometric properties.


2000 ◽  
Vol 6 (S2) ◽  
pp. 228-229
Author(s):  
M. A. Schofield ◽  
Y. Zhu

Quantitative off-axis electron holography in a transmission electron microscope (TEM) requires careful design of experiment specific to instrumental characteristics. For example, the spatial resolution desired for a particular holography experiment imposes requirements on the spacing of the interference fringes to be recorded. This fringe spacing depends upon the geometric configuration of the TEM/electron biprism system, which is experimentally fixed, but also upon the voltage applied to the biprism wire of the holography unit, which is experimentally adjustable. Hence, knowledge of the holographic interference fringe spacing as a function of applied voltage to the electron biprism is essential to the design of a specific holography experiment. Furthermore, additional instrumental parameters, such as the coherence and virtual size of the electron source, for example, affect the quality of recorded holograms through their effect on the contrast of the holographic fringes.


1948 ◽  
Vol 26a (2) ◽  
pp. 29-38 ◽  
Author(s):  
J. C. Arnell ◽  
G. O. Henneberry

The modified Kozeny equation has been found to be satisfactory for the measurement of the specific surfaces of carbon blacks having average particle diameters ranging from 0.01 to 0.1 μ to within ±10%. Comparative data were obtained from electron microscope counting and from low temperature nitrogen adsorption isotherms. The three methods examined gave results that were in satisfactory agreement, except when the carbon black was porous, and then the adsorption value was extremely large.


2020 ◽  
Vol 3 (1) ◽  
Author(s):  
Alison Finall

Surgical histopathologists are currently working in a context of high demand and requirement for fast turnaround times to report small diagnostic biopsies. Use of automated rapid cycle processing could improve turnaround times for reporting small biopsies. There are few papers in the medical literature describing detailed assessment of staining quality in verification of automated rapid cycle processing methods. This study assessed quality of immunohistochemical and haematoxylin and eosin staining of 62 paired endometrial biopsy samples processed using standard overnight cycles compared with rapid cycles of either 2, 3 or 4 hours duration. We found that small biopsies adequately fixed in 10% neutral buffered formalin were of sufficient staining quality for use in diagnostic reporting if they were processed for 3 or 4 hours. Five samples in our 2-hour group were of insufficient staining quality for full microscopic evaluation and histopathological diagnosis. As such, the 2-hour method was rejected. Rapid cycles of three hours duration will be adopted in our laboratory for processing small samples. Prospective monitoring of report turnaround times will be needed to assess impact on future outcomes for patients.


Sign in / Sign up

Export Citation Format

Share Document