scholarly journals Methods to homogenize ECC ozonesonde measurements across changes in sensing solution concentration or ozonesonde manufacturer

Author(s):  
Terry Deshler ◽  
Rene Stübi ◽  
Francis J. Schmidlin ◽  
Jennifer L. Mercer ◽  
Herman G. J. Smit ◽  
...  

Abstract. From the mid 1990s to the late 2000s the consistency of electrochemical cell ozonesonde long term records has been compromised by differences in manufacturers, Science Pump and ENSCI, and differences in recommended sensor solution concentrations, 1.0 % potassium iodide (KI) and the one half dilution 0.5 %. To investigate these differences a number of organizations independently undertook comparisons of the various ozonesonde types and solution concentrations, resulting in 197 ozonesonde comparison profiles. The goal is to derive transfer functions to allow measurements outside of standard recommendations, for sensor composition and ozonesonde type, to be converted to a standard measurement and thus homogenize the data to the expected accuracy of 5 % (10 %) in the stratosphere (troposphere). Subsets of these data have been analyzed previously and intermediate transfer functions derived. Here all the comparison data are analyzed to compare: 1) differences in sensor solution composition for a single ozonesonde type, 2) differences in ozonesonde type for a single sensor solution composition and 3) the manufacturer’s recommendations of 1.0 % KI solution for Science Pump and 0.5 % KI for ENSCI. From the recommendations it is clear that ENSCI ozonesondes and 1.0 % KI solution result in higher amounts of ozone sensed. The results indicate that differences in solution composition and in ozonesonde type display little pressure dependence at pressures ≥ 30 hPa and thus the transfer function can be characterized as a simple ratio of the less sensitive to the more sensitive method. This ratio is 0.96 for both solution concentration and ozonesonde type. The ratios differ at pressures

2017 ◽  
Vol 10 (6) ◽  
pp. 2021-2043 ◽  
Author(s):  
Terry Deshler ◽  
Rene Stübi ◽  
Francis J. Schmidlin ◽  
Jennifer L. Mercer ◽  
Herman G. J. Smit ◽  
...  

Abstract. Ozone plays a significant role in the chemical and radiative state of the atmosphere. For this reason there are many instruments used to measure ozone from the ground, from space, and from balloons. Balloon-borne electrochemical cell ozonesondes provide some of the best measurements of the ozone profile up to the mid-stratosphere, providing high vertical resolution, high precision, and a wide geographic distribution. From the mid-1990s to the late 2000s the consistency of long-term records from balloon-borne ozonesondes has been compromised by differences in manufacturers, Science Pump (SP) and ENSCI (EN), and differences in recommended sensor solution concentrations, 1.0 % potassium iodide (KI) and the one-half dilution: 0.5 %. To investigate these differences, a number of organizations have independently undertaken comparisons of the various ozonesonde types and solution concentrations, resulting in 197 ozonesonde comparison profiles. The goal of this study is to derive transfer functions to allow measurements outside of standard recommendations, for sensor composition and ozonesonde type, to be converted to a standard measurement and thus homogenize the data to the expected accuracy of 5 % (10 %) in the stratosphere (troposphere). Subsets of these data have been analyzed previously and intermediate transfer functions derived. Here all the comparison data are analyzed to compare (1) differences in sensor solution composition for a single ozonesonde type, (2) differences in ozonesonde type for a single sensor solution composition, and (3) the World Meteorological Organization's (WMO) and manufacturers' recommendations of 1.0 % KI solution for Science Pump and 0.5 % KI for ENSCI. From the recommendations it is clear that ENSCI ozonesondes and 1.0 % KI solution result in higher amounts of ozone sensed. The results indicate that differences in solution composition and in ozonesonde type display little pressure dependence at pressures  ≥  30 hPa, and thus the transfer function can be characterized as a simple ratio of the less sensitive to the more sensitive method. This ratio is 0.96 for both solution concentration and ozonesonde type. The ratios differ at pressures < 30 hPa such that OZ0. 5%/OZ1. 0 % =  0. 90 + 0. 041 ⋅ log10(p) and OZSciencePump/OZENSCI =  0. 764 + 0. 133 ⋅ log10(p) for p in units of hPa. For the manufacturer-recommended solution concentrations the dispersion of the ratio (SP-1.0 / EN-0.5 %), while significant, is generally within 3 % and centered near 1.0, such that no changes are recommended. For stations which have used multiple ozonesonde types with solution concentrations different from the WMO's and manufacturer's recommendations, this work suggests that a reasonably homogeneous data set can be created if the quantitative relationships specified above are applied to the non-standard measurements. This result is illustrated here in an application to the Nairobi data set.


Viruses ◽  
2019 ◽  
Vol 11 (5) ◽  
pp. 424 ◽  
Author(s):  
Olga E. Ivanova ◽  
Maria S. Yarmolskaya ◽  
Tatiana P. Eremeeva ◽  
Galina M. Babkina ◽  
Olga Y. Baykova ◽  
...  

Polio and enterovirus surveillance may include a number of approaches, including incidence-based observation, a sentinel physician system, environmental monitoring and acute flaccid paralysis (AFP) surveillance. The relative value of these methods is widely debated. Here we summarized the results of 14 years of environmental surveillance at four sewage treatment plants of various capacities in Moscow, Russia. A total of 5450 samples were screened, yielding 1089 (20.0%) positive samples. There were 1168 viruses isolated including types 1–3 polioviruses (43%) and 29 different types of non-polio enteroviruses (51%). Despite using the same methodology, a significant variation in detection rates was observed between the treatment plants and within the same facility over time. The number of poliovirus isolates obtained from sewage was roughly 60 times higher than from AFP surveillance over the same time frame. All except one poliovirus isolate were Sabin-like polioviruses. The one isolate was vaccine-derived poliovirus type 2 with 17.6% difference from the corresponding Sabin strain, suggesting long-term circulation outside the scope of the surveillance. For some non-polio enterovirus types (e.g., Echovirus 6) there was a good correlation between detection in sewage and incidence of clinical cases in a given year, while other types (e.g., Echovirus 30) could cause large outbreaks and be almost absent in sewage samples. Therefore, sewage monitoring can be an important part of enterovirus surveillance, but cannot substitute other approaches.


2021 ◽  
Vol 922 (2) ◽  
pp. 248
Author(s):  
Zhang XueGuang ◽  
Zhang YingFei ◽  
Cheng PeiZhen ◽  
Wang BaoHan ◽  
Lv Yi-Li ◽  
...  

Abstract In this manuscript, the composite galaxy SDSS J103911-000057 (=SDSS J1039) is reported as a true Type-2 AGN candidate without hidden BLRs. Only narrow emission lines, not broad, detected in SDSS J1039 can be confirmed both by the F-test technique and by the expected broad emission lines with an EW smaller than 13.5 Å with a 99% confidence level. Meanwhile, a reliable AGN power-law component is preferred with a confidence level higher than 7σ in SDSS J1039. Furthermore, the long-term variability of SDSS J1039 from Catalina Sky Survey can be described by the DRW process with an intrinsic variability timescale τ ∼ 100 days, similar to normal quasars. And, based on BH mass in SDSS J1039 through the M BH–σ relation and on the correlation between AGN continuum luminosity and total Hα luminosity, the expected broad Hα, if there was one, could be reconstructed with a line width of about 300–1000 km s−1 and with a line flux of about 666 × 10−17 erg s−1 cm−2 under the virialization assumption to BLRs, providing robust evidence to reject the probability that the intrinsic probable broad Hα was overwhelmed by noises of the SDSS spectrum in SDSS J1039. Moreover, SDSS J1039 follows the same correlation between continuum luminosity and [O iii] line luminosity as the one for normal broad-line AGN, indicating SDSS J1039 classified as a changing-look AGN in the dim state can be ruled out. Therefore, under the current knowledge, SDSS J1039 is a better candidate for a true Type-2 AGN.


2017 ◽  
Vol 23 ◽  
pp. 50
Author(s):  
Jothydev Kesavadev ◽  
Shashank Joshi ◽  
Banshi Saboo ◽  
Hemant Thacker ◽  
Arun Shankar ◽  
...  

2005 ◽  
Vol 44 (03) ◽  
pp. 107-117
Author(s):  
R. G. Meyer ◽  
W. Herr ◽  
A. Helisch ◽  
P. Bartenstein ◽  
I. Buchmann

SummaryThe prognosis of patients with acute myeloid leukaemia (AML) has improved considerably by introduction of aggressive consolidation chemotherapy and haematopoietic stem cell transplantation (SCT). Nevertheless, only 20-30% of patients with AML achieve long-term diseasefree survival after SCT. The most common cause of treatment failure is relapse. Additionally, mortality rates are significantly increased by therapy-related causes such as toxicity of chemotherapy and complications of SCT. Including radioimmunotherapies in the treatment of AML and myelodyplastic syndrome (MDS) allows for the achievement of a pronounced antileukaemic effect for the reduction of relapse rates on the one hand. On the other hand, no increase of acute toxicity and later complications should be induced. These effects are important for the primary reduction of tumour cells as well as for the myeloablative conditioning before SCT.This paper provides a systematic and critical review of the currently used radionuclides and immunoconjugates for the treatment of AML and MDS and summarizes the literature on primary tumour cell reductive radioimmunotherapies on the one hand and conditioning radioimmunotherapies before SCT on the other hand.


2018 ◽  
pp. 49-68 ◽  
Author(s):  
M. E. Mamonov

Our analysis documents that the existence of hidden “holes” in the capital of not yet failed banks - while creating intertemporal pressure on the actual level of capital - leads to changing of maturity of loans supplied rather than to contracting of their volume. Long-term loans decrease, whereas short-term loans rise - and, what is most remarkably, by approximately the same amounts. Standardly, the higher the maturity of loans the higher the credit risk and, thus, the more loan loss reserves (LLP) banks are forced to create, increasing the pressure on capital. Banks that already hide “holes” in the capital, but have not yet faced with license withdrawal, must possess strong incentives to shorten the maturity of supplied loans. On the one hand, it raises the turnovers of LLP and facilitates the flexibility of capital management; on the other hand, it allows increasing the speed of shifting of attracted deposits to loans to related parties in domestic or foreign jurisdictions. This enlarges the potential size of ex post revealed “hole” in the capital and, therefore, allows us to assume that not every loan might be viewed as a good for the economy: excessive short-term and insufficient long-term loans can produce the source for future losses.


Diabetes ◽  
2018 ◽  
Vol 67 (Supplement 1) ◽  
pp. 1129-P
Author(s):  
SILVINA GALLO ◽  
BERNARD CHARBONNEL ◽  
ALLISON GOLDMAN ◽  
HARRY SHI ◽  
SUSAN HUYCK ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document