Numerical Study of the Influence of Air Vent Area and Air Mass Flux on the Thermal Comfort of Car Occupants

Author(s):  
Joachim Currle ◽  
Jürgen Maué
2019 ◽  
Vol 29 (8) ◽  
pp. 1101-1117
Author(s):  
Lin Yang ◽  
Xiangdong Li ◽  
Jiyuan Tu

Due to the fast development of high-speed rail (HSR) around the world, high-speed trains (HSTs) are becoming a strong competitor against airliners in terms of long-distance travel. Compared with airliner cabins, HST cabins have much larger window sizes. When the big windows provide better lighting and view of the scenery, they also have significant effects on the thermal conditions in the cabins due to the solar radiation through them. This study presents a numerical study on the solar radiation on the thermal comfort in a typical HST cabin. The effect of solar radiation was discussed in terms of airflow pattern, temperature distribution and thermal comfort indices. Parametric studies with seven different daytime hours were carried out. The effect of using the roller curtain was also studied. The overall cabin air temperature, especially near passengers, was found to have significantly increased by solar radiation. Passengers sitting next to windows were recorded to have an obvious thermal comfort variation at different hours of the day. To improve the passengers’ comfort and reduce energy consumption during hot weather, the use of a curtain could effectively reduce the solar radiation effect in the cabin environment.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
J. Prakash ◽  
S. Gouse Mohiddin ◽  
S. Vijaya Kumar Varma

A numerical study of buoyancy-driven unsteady natural convection boundary layer flow past a vertical cone embedded in a non-Darcian isotropic porous regime with transverse magnetic field applied normal to the surface is considered. The heat and mass flux at the surface of the cone is modeled as a power law according to qwx=xm and qw*(x)=xm, respectively, where x denotes the coordinate along the slant face of the cone. Both Darcian drag and Forchheimer quadratic porous impedance are incorporated into the two-dimensional viscous flow model. The transient boundary layer equations are then nondimensionalized and solved by the Crank-Nicolson implicit difference method. The velocity, temperature, and concentration fields have been studied for the effect of Grashof number, Darcy number, Forchheimer number, Prandtl number, surface heat flux power-law exponent (m), surface mass flux power-law exponent (n), Schmidt number, buoyancy ratio parameter, and semivertical angle of the cone. Present results for selected variables for the purely fluid regime are compared with the published results and are found to be in excellent agreement. The local skin friction, Nusselt number, and Sherwood number are also analyzed graphically. The study finds important applications in geophysical heat transfer, industrial manufacturing processes, and hybrid solar energy systems.


AIAA Journal ◽  
2007 ◽  
Vol 45 (9) ◽  
pp. 2213-2223 ◽  
Author(s):  
Kent H. Lyle ◽  
Jay B. Jeffries ◽  
Ronald K. Hanson ◽  
Michael Winter

Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 8130
Author(s):  
Ziwen Dong ◽  
Liting Zhang ◽  
Yongwen Yang ◽  
Qifen Li ◽  
Hao Huang

Stratified air distribution systems are commonly used in large space buildings. The research on the airflow organization of stratified air conditioners is deficient in terms of the analysis of multivariable factors. Moreover, studies on the coupled operation of stratified air conditioners and natural ventilation are few. In this paper, taking a Shanghai Airport Terminal departure hall for the study, air distribution and thermal comfort of the cross-section at a height of 1.6 m are simulated and compared under different working conditions, and the effect of natural ventilation coupling operation is studied. The results show that the air distribution is the most uniform and the thermal comfort is the best (predicted mean vote is 0.428, predicted percentage of dissatisfaction is 15.2%) when the working conditions are 5.9% air supply speed, 11 °C cooling temperature difference and 0° air supply angle. With the coupled operation of natural ventilation, the thermal comfort can be improved from Grade II to Grade I.


2006 ◽  
Vol 2006 (108) ◽  
pp. 509-528 ◽  
Author(s):  
Borong Lin ◽  
Yingxin Zhu ◽  
Xiaofeng Li ◽  
Youguo Qin ◽  
Shinji Yoshida ◽  
...  

2021 ◽  
Vol 246 ◽  
pp. 03005
Author(s):  
Eusébio Conceição ◽  
João Gomes ◽  
Mª Manuela Lúcio ◽  
Hazim Awbi

In this numerical study the energy production in solar collectors in a University building used to improve the internal thermal conditions is made. Passive and active solutions, using external solar collector and internal thermo-convectors, are used. The numerical simulation, in transient conditions, is done for a winter typical day with clean sky. This numerical study was carried out using a software that simulates the Building Dynamic Response with complex topology in transient conditions. The software evaluates the human thermal comfort and indoor air quality levels that the occupants are subjected, Heated Ventilation and Air Conditioned energy consumption, indoor thermal variables and other parameters. The university building has 107 compartments and is located in a Mediterranean-type environment. External solar water collectors, placed above the building’s roof, and internal thermo-convectors of water/air type, using mixing ventilation, are used as passive and active strategies, respectively. The thermal comfort level, using the Predicted Mean Vote index, and the indoor air quality, using the carbon dioxide concentration, are evaluated. The results show that in winter conditions the solar collectors improve the thermal comfort conditions of the occupants. The indoor air quality, in all ventilated spaces, is also guaranteed.


1988 ◽  
Vol 110 (2) ◽  
pp. 342-346
Author(s):  
R. F. Gans ◽  
A. G. Johnson ◽  
S. B. Malanoski

We have measured the separation and central pressure of a slightly concave axially symmetric pressurized bearing as a function of lubricant (air) mass flux and bearing load. We find that a mean face slope of 1.6 × 10−3 makes a dramatic difference in the behavior of the bearing, reducing the central pressure by more than a factor of two and eliminating the need for overpressures to start the system. We have also explored the behavior of the system analytically and find excellent agreement between theory and experiment.


2019 ◽  
Vol 29 (11) ◽  
pp. 4462-4483
Author(s):  
Zohir Younsi ◽  
Lounes Koufi ◽  
Hassane Naji

Purpose A comprehensive investigation on the outlet air position effects on the thermal comfort and air quality has been achieved. In addition, airflow and temperature distributions in ventilated cavities filled with an air-CO2 mixture with mixed convection are predicted. The airflow enters from the cavity through an opening in the lower side of the left vertical wall and exits through the opening in one wall of the cavity. This paper aims to investigate the outlet location effect, four different placement configurations of output ports are considered. Three of them are placed on the upper side and the fourth on top of the opposite side of the inlet opening. A uniform heat and CO2 contaminant source are applied on the left vertical wall, while the remaining walls are impermeable and adiabatic to heat and solute. The cooling efficiency inside the enclosure and the average fluid temperature are computed for different Reynolds and Rayleigh numbers to find the most suitable fluid outlet position that ensures indoor comfortable conditions while effectively removing heat and the contaminant. This is demonstrated by three relevant indices, namely, the effectiveness for heat removal, the contaminant removal and the index of indoor air quality. Design/methodology/approach The simulations were performed via the finite-volume scSTREAM CFD solver V11. Three different values of CO2 amount are considered, namely, 103, 2 × 103 and 3 × 103 ppm, the Reynolds number being in the range 100 ≤ Re ≤ 800. Findings Based on the findings obtained, it is the configuration whose air outlet is placed near the heat source and the contaminant, which provides a better air distribution and a ventilation efficiency compared to the others ventilation strategies. Originality/value The studies on heat and mass transfers by natural and forced convection in ventilated cavities remain a fruitful research topic. Thereby, such a study deals with different ventilation strategies through cavities containing an air-CO2 mixture subjected to a mixed regime. In particular, the air inlet velocity and contaminant sources’ effects on thermal comfort and air quality have been investigated.


Sign in / Sign up

Export Citation Format

Share Document