scholarly journals Effect of blood volume on analytical bias in dried blood spots prepared for newborn screening external quality assurance

Bioanalysis ◽  
2020 ◽  
Vol 12 (2) ◽  
pp. 99-109 ◽  
Author(s):  
Stuart J Moat ◽  
Catherine Dibden ◽  
Lesley Tetlow ◽  
Caroline Griffith ◽  
Jim Chilcott ◽  
...  

Aim: Dried blood spots (DBS) are used for the analysis of more than 2000 biomarkers. We assessed a range of analyte concentrations and diameters of DBS. Materials & methods: DBS samples were created by the application of increasing volumes of whole blood prepared by the UK NEQAS Quality Assurance Laboratory. Samples were analyzed in four separate laboratories. Results: Volumes less than 25 μl (8 mm) and more than 75 μl (14 mm) created unsatisfactory analytical biases. Results obtained from peripheral subpunches tended to be higher than those from a central subpunch. Conclusion: DBS diameters formed from nonvolumetric application of blood to filter paper can be used to assess whether measurement bias will be within acceptable limits according to the analyte being quantified. DBS received for newborn screening in the UK with diameters less than 8 mm and those more than 14 mm should be rejected.

2002 ◽  
Vol 317 (1-2) ◽  
pp. 191-197 ◽  
Author(s):  
Néstor A. Chamoles ◽  
Mariana Blanco ◽  
Daniela Gaggioli ◽  
Carina Casentini

1987 ◽  
Vol 75 (3) ◽  
pp. 213-216 ◽  
Author(s):  
Edward R. B. McCabe ◽  
Shu-Zhen Huang ◽  
William K. Seltzer ◽  
Martha L. Law

2016 ◽  
Vol 62 (3) ◽  
pp. 466-475 ◽  
Author(s):  
Roanna S George ◽  
Stuart J Moat

Abstract BACKGROUND The analysis of dried blood spots has been used routinely for newborn screening since the early 1970s, and the number of disorders screened has expanded substantially in recent years. However, there is a lack of evidence regarding minimum blood spot quality acceptance criteria for sample analysis. METHODS Blood pools were spiked with phenylalanine, tyrosine, leucine, methionine, octanoylcarnitine, decanoylcarnitine, isovalerylcarnitine, glutarylcarnitine, thyroid-stimulating hormone, and immunoreactive trypsinogen to concentrations at the analytical cutoffs used in UK screening protocols. We evaluated the effect of sample volume applied to the card (10, 20, 50, 75, and 100 μL), punch location (central vs peripheral), and sample quality (double layering, applying blood to both sides of the filter paper, multispotting, applying insufficient sample, and compressing the sample after application). RESULTS Compression of blood spots produced significantly lower results (14%–44%) for all analytes measured (P < 0.001). Smaller blood spots produced significantly lower results (15%–24% for 10-μL vs 50-μL sample size) for all analytes at all concentrations measured (P < 0.001). Results obtained from peripheral punches were higher than those from a central punch, although this did not reach statistical significance for all analytes. Insufficient and multispotted samples demonstrated heterogeneous results. CONCLUSIONS All blood spots containing ≤20 μL (blood spot diameter <8 mm), those in which blood has not fully penetrated the filter paper, and all samples with evidence of compression should be rejected, since there is a risk of producing false-negative results.


2013 ◽  
Vol 13 (1) ◽  
Author(s):  
Pieter W Smit ◽  
Thomas van der Vlis ◽  
David Mabey ◽  
John Changalucha ◽  
Julius Mngara ◽  
...  

1985 ◽  
Vol 31 (2) ◽  
pp. 235-238 ◽  
Author(s):  
F W Spierto ◽  
T L Hearn ◽  
F H Gardner ◽  
W H Hannon

Abstract Aliquots (0.1 mL) of whole-blood pools prepared to contain various concentrations of phenylalanine were applied to filter-paper collection cards, dried, and stored in sealed bags. We measured the phenylalanine content of the dried blood spots by bioassay, fluorometry, and "high-performance" liquid chromatography, and found that the concentrations remained constant for two years when samples were kept at -20 degrees C or lower. Intra- and interlaboratory studies showed that results for phenylalanine were greater for laboratories using bioassay procedures than for those using fluorometric procedures. Further, CVs (both among- and within-laboratory) obtained with fluorometric procedures were nearly half as great as the CVs obtained by laboratories using bioassay techniques.


2002 ◽  
Vol 318 (1-2) ◽  
pp. 133-137 ◽  
Author(s):  
Néstor A Chamoles ◽  
Mariana Blanco ◽  
Daniela Gaggioli ◽  
Carina Casentini

2016 ◽  
Author(s):  
S. Dhanasekaran ◽  
G. Dhinakar Raj ◽  
A. R. Vignesh ◽  
S. T. Selvan ◽  
B. Prakash ◽  
...  

AbstractAccurate sex identification of pure line chickens in their early age has significant economic impact in breeding industry. In the recent years, range of Polymerase Chain Reaction (PCR) based sex determination techniques are routinely used to identify the sex of parent lines in breeding industries, however purified DNA is a prerequisite. Hence this study was aimed to develop a rapid and inexpensive PCR based gender identification method for chicken using whole blood samples and dried blood spots as template for PCR without DNA extraction. In addition, practicability of two W-chromosome specific gene targets in chicken for sex determination also characterised. Successful amplification of sex specific fragments and an internal control was achieved with the range of 0.125μl and 0.250μl volume of whole blood on filter paper (~1 mm) prepared from chicken and dried blood spot. This technique does not require DNA extraction, freeze/thawing of blood samples, pre-treatment with any reagents, dilution of whole blood or dried blood spots on filter paper. It can be carried out with commercially available Taq polymerase enzymes with increased concentration of MgCl2 (3 mM) and 0.5% of DMSO without optimisation of PCR buffers. In conclusion, as compared to the existing PCR based sex identification techniques, the present approach is relatively economic, time saving, requires minimal steps and eliminates the need for DNA extraction.


2021 ◽  
Vol 26 ◽  
pp. 100720
Author(s):  
Archana Natarajan ◽  
Rita Christopher ◽  
Shruti V. Palakuzhiyil ◽  
Sadanandavalli Retnaswami Chandra

2017 ◽  
Vol 50 (7-8) ◽  
pp. 431-435 ◽  
Author(s):  
Ana Carolina Breier ◽  
Jaqueline Cé ◽  
Jamila Mezzalira ◽  
Vanessa V. Daitx ◽  
Vitoria C. Moraes ◽  
...  

1996 ◽  
Vol 52 (4) ◽  
pp. 308-309
Author(s):  
B. Schweiger ◽  
C. Kücherer ◽  
C. Fleischer ◽  
H. v. Spreckelsen ◽  
P. Zablocki-Kaiser ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document