scholarly journals Comparative evaluation of the precision of cone-beam computed tomography and surgical intervention in the determination of periodontal bone defects: A clinicoradiographic study

2020 ◽  
Vol 24 (2) ◽  
pp. 127
Author(s):  
Unnati Pitale ◽  
Hitesh Mankad ◽  
Rohit Pandey ◽  
PritishChandra Pal ◽  
Shikha Dhakad ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3070
Author(s):  
Sebastian Iwaszenko ◽  
Jakub Munk ◽  
Stefan Baron ◽  
Adam Smoliński

Modern dentistry commonly uses a variety of imaging methods to support diagnosis and treatment. Among them, cone beam computed tomography (CBCT) is particularly useful in presenting head structures, such as the temporomandibular joint (TMJ). The determination of the morphology of the joint is an important part of the diagnosis as well as the monitoring of the treatment results. It can be accomplished by measurement of the TMJ gap width at three selected places, taken at a specific cross-section. This study presents a new approach to these measurements. First, the CBCT images are denoised using curvilinear methods, and the volume of interest is determined. Then, the orientation of the vertical cross-section plane is computed based on segmented axial sections of the TMJ head. Finally, the cross-section plane is used to determine the standardized locations, at which the width of the gap between condyle and fossa is measured. The elaborated method was tested on selected TMJ CBCT scans with satisfactory results. The proposed solution lays the basis for the development of an autonomous method of TMJ index identification.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Mehmet Hakan Kurt ◽  
Nilsun Bağış ◽  
Cengiz Evli ◽  
Cemal Atakan ◽  
Kaan Orhan

Abstract Background To examine the influence of voxel sizes to detect of peri-implant fenestration defects on cone beam computed tomography (CBCT) images. Materials and methods This study performed with three sheep heads both maxilla and mandible and two types of dental implant type 1 zirconium implant (Zr40) (n = 6) and type 2 titanium implant (Ti22) (n = 10). A total of 14 peri-implant fenestrations (8 buccal surfaces, 6 palatal/lingual surface) were created while 18 surfaces (8 buccal, 10 palatal/lingual) were free of fenestrations. Three observers have evaluated the images of fenestration at each site. Images obtained with 0.75 mm3, 0.100 mm3, 0.150 mm3, 0.200 mm3, and 0.400 mm3 voxel sizes. For intra- and inter-observer agreements for each voxel size, Kappa coefficients were calculated. Results Intra- and inter-observer kappa values were the highest for 0.150 mm3, and the lowest in 0.75 mm3 and 0.400 mm3 voxel sizes for all types of implants. The highest area under the curve (AUC) values were found higher for the scan mode of 0.150 mm3, whereas lower AUC values were found for the voxel size for 0.400 mm3. Titanium implants had higher AUC values than zirconium with the statistical significance for all voxel sizes (p ≤ 0.05). Conclusion A voxel size of 0.150 mm3 can be used to detect peri-implant fenestration bone defects. CBCT is the most reliable diagnostic tool for peri-implant fenestration bone defects.


2015 ◽  
Vol 15 (1) ◽  
Author(s):  
Berkan Celikten ◽  
Ceren Feriha Uzuntas ◽  
Sebnem Kursun ◽  
Ayse Isil Orhan ◽  
Pelin Tufenkci ◽  
...  

2012 ◽  
Vol 26 (6) ◽  
pp. 550-556 ◽  
Author(s):  
Isabela Maria de Carvalho Crusoé Silva ◽  
Deborah Queiroz de Freitas ◽  
Glaucia Maria Bovi Ambrosano ◽  
Frab Norberto Bóscolo ◽  
Solange Maria Almeida

Sign in / Sign up

Export Citation Format

Share Document