Bend testing of micro-scale bulk metal specimens using a chip-scale test instrument

2015 ◽  
Vol 2015 (DPC) ◽  
pp. 000827-000864
Author(s):  
Li-Anne Liew ◽  
David T. Read ◽  
Nicholas Barbosa

We describe bend testing on micro-scale specimens of 302 stainless steel, using a MEMS test instrument. Bend testing is a common way of measuring the flexural stiffness of structural materials across many size scales, from thin laminate sheets to large weldments. Whereas the stiffness of a material under tensile loading is given by the Young's Modulus, the flexural stiffness, or the stiffness in bending, is much lower. In the past two decades, conventional materials testing machines and the specimens themselves have undergone miniaturization for the purpose of evaluating the mechanical properties of miniaturized mechanical components such as sensors and biomedical implants, for which the smallest specimen dimension is typically around 1 mm [2]. Another driver for miniaturizing the testing apparatuses is to test materials with inherently small form factors such as wires and thin films [3]. Now the emerging 3D printing technology is creating another need for material property measurement at micrometer size scales, to accurately capture the property gradients resulting from the layered manufacturing. However, with ever increasing miniaturization comes increasing difficulty in specimen handling, gripping, and alignment. Concurrently, MEMS technology has been used over the past 2 decades to fabricate small actuators and sensors for mechanical testing of materials of thin films [4] or nanoscale materials such as nanowires. We seek to use the advantages of MEMS to study the mechanical properties of bulk materials rather than thin films, but at the micrometer scale. We believe this will result in greater accuracy and spatial resolution of property measurements of structural materials used in civil infrastructure, aerospace, transportation and energy industries, as well as characterizing manufacturing processes that lead to steep property gradients such as 3D printed components. Our approach is to use MEMS actuators as chip-scale re-useable test instruments into which small specimens sectioned from bulk materials can be inserted and tested [5], to reduce the cost and time to obtain large data sets and to allow the measurements to be done in-situ in harsh environments. We will describe the design of a micro-size 302 stainless steel specimen, and the use of a MEMS test instrument for performing the bend testing on the specimens. The specimen's gage section was 350 um long, 65 um wide and 25 um thick, and was made by lithographic etching of a foil. The MEMS test instrument was fabricated from silicon and glass wafers. The specimens were inserted into the MEMS test chip and the silicon actuator applied static bending loads to the specimen. Displacements were measured from optical microscope images, and the force was calculated from the applied voltage and the known (measured) stiffness of the silicon actuator. The applied force from the MEMS actuator was measured directly, without any specimen, using a custom table-top force probe and load cell apparatus, and was in agreement with the force calculated from the applied voltage. The flexural stiffness of the micro specimens were measured, using the MEMS test device, at 90 – 130 N/m. These values were validated by independently testing the specimens with the much larger table-top force probe. We thus show that our MEMS test chip can be used to perform bending tests on micro scale specimens of bulk materials, but with a 1000-fold reduction in size compared to table-top force-measuring apparatuses.

MRS Bulletin ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 82-91 ◽  
Author(s):  
William D. Nix

AbstractRecalling some of the progress that has been made in understanding the mechanical properties of materials over the past 50 years or so reveals the importance of remembering and applying old lessons when addressing new opportunities in materials research. Often, the classical lessons of the past are especially useful as a guide for thinking about new problems. Such an approach to new problems is intimately connected to the creation of simple models that capture the essential features of the phenomena involved. Experience shows that, although such efforts might not pay off immediately, they come to be useful many years later when new problems are confronted. The merit of applying old lessons to new problems is described herein by using examples from the author's career in characterizing and understanding the mechanical properties of materials. It is hoped that these lessons are sufficiently general to be applied to other areas of materials research. Problems ranging from the high-temperature creep resistance of titanium aluminides, to the residual stresses in deposited thin films, to diffusive relaxation processes in thin films, to the size dependence of the strength of crystalline materials at the nanometer scale, all provide examples of how applying lessons of the past can help to understand new problems. An effort is also made to identify new, emerging problems in materials research where the application of the lessons of the past, together with new capabilities of the future, can come together to produce a fresh understanding of material behavior.


1993 ◽  
Vol 317 ◽  
Author(s):  
M. Chinmulgund ◽  
R. B. Inturi ◽  
J. A. Barnard

ABSTRACTThin films of Ti, Al, TiAl and Ti3Al were deposited by dc magnetron sputtering onto 2” dia. oxidized Si<111> wafers and their mechanical properties were studied by measuring the internal stress in the films. Ti and Ti3Al films show hexagonal structure with preferred orientation in the (0002) direction. TiAl is tetragonal, nanocrystalline, and (111) oriented; Al is random fee polycrystalline in nature. Young's Modulii of thin films of these materials were calculated from the stress temperature plots. The E values of TiAI and Ti3Al thin films were found to be significantly higher than those of the bulk Materials.


2014 ◽  
Vol 2014 (DPC) ◽  
pp. 000632-000664
Author(s):  
Li-Anne Liew ◽  
David T. Read ◽  
Nicholas Barbosa

Fatigue, the degradation of a material's mechanical properties due to cyclic loading, is a critical issue limiting the reliability of structural materials[1]. Fatigue testing of materials is typically carried out in controlled laboratory conditions on specially prepared specimens, and the results are extrapolated to real world conditions. In the past two decades, conventional fatigue testing machines and specimens have undergone miniaturization for the purpose of evaluating the fatigue properties of miniaturized mechanical components such as sensors and biomedical implants, with the smallest test specimens having dimensions on the order of 1 mm length [2] or consisting of foils and wires [3]. Challenges with miniaturization include difficulty in specimen handling, gripping, and alignment. At the same time, MEMS technology has been used to fabricate the actuators and sensors for fatigue testing of thin films [4]. In this approach, the specimen is typically part of the MEMS actuator and is fabricated in-situ. While this eliminates the problems with specimen gripping and alignment, it limits the specimen materials to those from which MEMS actuators and sensors can be readily fabricated, is destructive to the MEMs device, and furthermore is typically limited to thin films. We seek to use the advantages of MEMS to study the fatigue properties of bulk materials rather than thin films, but at the micrometer scale. This allows for greater accuracy and spatial resolution, compared to the state of the art, of property measurements of structural materials such as aluminum and stainless steel alloys as well as other materials used in civil infrastructure, aerospace, transportation and energy industries. Our approach is to use MEMS as chip-scale re-useable test instruments into which small specimens cut from bulk materials can be inserted and tested [5]. We describe the design of the MEMS test instrument and the metal foil specimen, whose gage section was 135 um wide and 25 um thick. The test instrument was fabricated from silicon and glass wafers, and the specimens were etched from commercially available Al 1145 H19 foil. Our S-N curve agrees within expectation with published values for similar aluminum alloys tested using conventional methods at much larger specimen size scales, and the fracture surface shows distinct regions corresponding to slow and fast crack growth. We envision this test technique as a tool to further the study of the fatigue properties of structural materials.


Author(s):  
A. K. Rai ◽  
P. P. Pronko

Several techniques have been reported in the past to prepare cross(x)-sectional TEM specimen. These methods are applicable when the sample surface is uniform. Examples of samples having uniform surfaces are ion implanted samples, thin films deposited on substrates and epilayers grown on substrates. Once device structures are fabricated on the surfaces of appropriate materials these surfaces will no longer remain uniform. For samples with uniform surfaces it does not matter which part of the surface region remains in the thin sections of the x-sectional TEM specimen since it is similar everywhere. However, in order to study a specific region of a device employing x-sectional TEM, one has to make sure that the desired region is thinned. In the present work a simple way to obtain thin sections of desired device region is described.


2011 ◽  
Vol 99 (2) ◽  
pp. 239-244 ◽  
Author(s):  
T.T.H. Pham ◽  
E. Le Bourhis ◽  
P. Goudeau ◽  
P. Guérin

2009 ◽  
Vol 113 (2) ◽  
pp. 976-983 ◽  
Author(s):  
Wonbong Jang ◽  
Jongchul Seo ◽  
Choonkeun Lee ◽  
Sang-Hyon Paek ◽  
Haksoo Han

Sign in / Sign up

Export Citation Format

Share Document