RUBIDIUM AS A MARKER FOR MEXICAN BEAN BEETLES, EPILACHNA VARIVESTIS (COLEOPTERA: COCCINELLIDAE)

1976 ◽  
Vol 108 (4) ◽  
pp. 337-339 ◽  
Author(s):  
Merle Shepard ◽  
V. H. Waddill

AbstractMexican bean beetles, Epilachna varivestis Mulsant, were marked with rubidium by allowing larvae and adults to feed on foliage of bean plants treated with a rubidium chloride solution. Detection of rubidium was effected by atomic absorption spectroscopy. Adults which had fed for 4 days on rubidium-chloride-treated plants then transferred to untreated plants contained elevated levels of rubidium up to 34 days. The presence of rubidium was not detectable in the progeny of treated beetles at levels significantly different from controls. Consumption of rubidium-chloride-treated foliage produced no observable detrimental effects on the beetles. The technique allowed them to acquire a relatively permanent label through their normal feeding activity.

2018 ◽  
Vol 28 (4) ◽  
pp. 1259-1264
Author(s):  
Kiril Lisichkov ◽  
Katerina Atkovska ◽  
Neven Trajchevski ◽  
Orce Popovski ◽  
Nadica Todorovska

The presence of some chemical compounds at higher levels than maximum permissible concentrations (MPC) in the drinking water, suggests of water resources pollution. In this paper the following elements were analyzed: total arsenic, cadmium, lead, cooper and zinc. Twelve samples of water from the water supply system from the city of Skopje were examined during one year from three different springs. Also, ten samples of bottled water from three producers from the Macedonian market were tested.The determined average mass concentrations of total As, Cd(II), Pb(II), Cu(II) and Zn(II) in the analyzed water samples from the water supply system are 1.35 μg/l, 0.06 μg/l, 0.6 μg/l, 0.9 μg/l and 1,12 μg/l, respectively, and for the tested bottled water, the mean values ranges from 0.56 - 0.83 μg total As / l, 0.053 - 0.056 μg Cd(II)/l, 0.51 - 0.54 μg Pb(II)/l , 0.6 - 0.87 μg Cu(II)/l and 0.68 - 0.8 μg Zn(II)/l water.The following instrumental analytical methods and techniques were used for the analysis of the tested samples of drinking water: flame atomic absorption spectroscopy (AAS), atomic absorption spectroscopy with hydride cеll, electrothermal atomic absorption spectroscopy.The obtained results are shown in tables and graphic form. According to the obtained results a comparative analysis was carried out indicate that it is a water of good quality that can be used in different branches of the process industry.The obtained results in this paper do not exceed the values of the MPC of the Republic of Macedonia prescribed by the legal regulations for the drinking water, which confirm the health safety of the drinking water from the water supply system in the city of Skopje and the packed waters from the Macedonian market in relation to the tested elements.


Sign in / Sign up

Export Citation Format

Share Document