scholarly journals Prefabricated, Low Cost and Ready to Install Water Treatment Unit Operation Modules for The Townships of Sri Lanka

Author(s):  
S. Sumanaweera ◽  
G. G. N. Gunawardena
2020 ◽  
Vol 26 (5) ◽  
pp. 200437-0
Author(s):  
Mainak Bhattacharya ◽  
Koyel Bandyopadhyay ◽  
Anirban Gupta

Bacteriological contamination in drinking water is known to be responsible for the spread of various waterborne diseases. Although chlorine is frequently used as disinfectant in water treatment, low-cost disinfecting technologies in the villages of developing and under-developed countries are not yet successfully implemented. This study contributed in designing a simple and inexpensive water disinfection unit to produce chlorine from the naturally available dissolved chloride of groundwater by electrochlorination, using inert and cheap graphite electrodes. Laboratory-based experiments were performed in both batch and continuous flow reactors to study the effect of time, current, electro charge loading (ECL), and surface area of electrodes in chlorine generation and bacterial inactivation. Controlled experiments in continuous mode in the absence of chlorine further indicated the possibility of partial inactivation of bacteria under the influence of the electric field. Finally, a treatment unit with drilled anodes, and undrilled cathode electrodes, in continuous flow set-up was installed in four schools of four different villages in West Bengal, India. An average residual chlorine concentration and removal efficiency of total coliform in the designed systems were determined as 0.3 ± 0.07 mg/L, and 98.4% ± 1.6%, respectively.


2020 ◽  
Vol 0 (2) ◽  
pp. 21-25
Author(s):  
Nikolay Dubenok ◽  
Andrey Novikov ◽  
Sergei Borodychev ◽  
Maria Lamskova

At the stage of water treatment for irrigation systems, the efficiency capture coarse and fine mechanical impurities, as well as oil products and organic compounds affects the reliability of the equipment of the irrigation network and the safety of energy exchange processes in irrigated agricultural landscapes. The violation of work irrigation system can cause disruptions in irrigation schedules of agricultural crops, crop shortages, degradation phenomena on the soil and ecological tension. For the combined irrigation system, a water treatment unit has been developed, representing a hydrocyclone apparatus with a pipe filter in the case. For the capacity of 250 m3/h the main geometrical dimensions of hydrocyclone have been calculated. To organize the capture petroleum products and organic compounds, it has been proposed a modernization of a hydrocyclone unit, consisting in dividing the cylindrical part of the apparatus into two section. The first is section is for input irrigation water, the second one is for additional drainage of clarified irrigation water after sorption purification by the filter, placed on the disk and installed coaxially with the drain pipe and the pipe filter.


Waterlines ◽  
2012 ◽  
Vol 31 (1-2) ◽  
pp. 53-66 ◽  
Author(s):  
Richard Luff ◽  
Caetano Dorea

2018 ◽  
Vol 6 (3) ◽  
Author(s):  
Arie Herlambang

Clean water to poor communities who live in crowded municipal area is stillexpensive and a luxury. This condition is evidenced by the number of people whouse ground water for their daily water, because water taps still seems expensivefor them. Diarrheal disease is still relatively high for Indonesia, where nearly 16thousand people suffer from diarrhea due to poor sanitation. To help the poor inthe city, there are several alternative technologies that can be applied to publicaccess to clean water and adequate low-cost, including ground water treatmenttechnology with a filter system equipped with an ultraviolet sterilizer, or ozonegenerators, or using ultrafiltration, if possible can also use the reverse osmosismembrane that for fresh water. Arsinum is the best alternative should be chosenfor fulfilled potable water in slump area.Keywords : Sanitation, water treatment technology, portable water, low-cost, slump area


2020 ◽  
Vol 18 (1) ◽  
pp. 1148-1166
Author(s):  
Ganjar Fadillah ◽  
Septian Perwira Yudha ◽  
Suresh Sagadevan ◽  
Is Fatimah ◽  
Oki Muraza

AbstractPhysical and chemical methods have been developed for water and wastewater treatments. Adsorption is an attractive method due to its simplicity and low cost, and it has been widely employed in industrial treatment. In advanced schemes, chemical oxidation and photocatalytic oxidation have been recognized as effective methods for wastewater-containing organic compounds. The use of magnetic iron oxide in these methods has received much attention. Magnetic iron oxide nanocomposite adsorbents have been recognized as favorable materials due to their stability, high adsorption capacities, and recoverability, compared to conventional sorbents. Magnetic iron oxide nanocomposites have also been reported to be effective in photocatalytic and chemical oxidation processes. The current review has presented recent developments in techniques using magnetic iron oxide nanocomposites for water treatment applications. The review highlights the synthesis method and compares modifications for adsorbent, photocatalytic oxidation, and chemical oxidation processes. Future prospects for the use of nanocomposites have been presented.


Nanomaterials ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1804
Author(s):  
Guangmin Ren ◽  
Hongtao Han ◽  
Yixuan Wang ◽  
Sitong Liu ◽  
Jianyong Zhao ◽  
...  

Photocatalysis holds great promise as an efficient and sustainable oxidation technology for application in wastewater treatment. Rapid progress developing novel materials has propelled photocatalysis to the forefront of sustainable wastewater treatments. This review presents the latest progress on applications of photocatalytic wastewater treatment. Our focus is on strategies for improving performance. Challenges and outlooks in this promising field are also discussed. We hope this review will help researchers design low-cost and high-efficiency photocatalysts for water treatment.


2017 ◽  
Vol 18 (3) ◽  
pp. 843-852
Author(s):  
Travis D. Gardner ◽  
Joe D. Guggenberger

Abstract Ceramic pot filters (CPFs) are an effective point of use water treatment device in developing nations due to their low cost and effectiveness. CPFs are gravity fed, typically making water production a major limiting factor to a CPF's lifetime and acceptability. Directly connecting CPFs to in-line pumping systems or systems with an elevated storage tank would allow filter usage for constant water treatment at increased pressures, increasing the quantity of treated water. Ceramic disks were manufactured for testing in a specially designed housing apparatus. Filters of varying thicknesses and clay to sawdust mass ratios were manufactured to fit tightly. Flowrate and microbiological removal efficacy (logarithmic reduction value (LRV)) were determined over the testing period at various pressures. Flowrate values ranged from 2.44 to 9.04 L per hour, significantly higher than traditional CPF technology. LRVs ranged from 1.1 to 2.0, lower than traditional CPF technology but still effective at removing most Escherichia coli and total coliform bacteria. Filters proved effective at removing total and fecal coliforms at pressures less than 70 kilopascals. The optimum filter had a thickness of 3.2 cm and clay to sawdust ratio of 6:1 by mass. Filters proved to be ineffective if flowrates were above 5 L/h.


2015 ◽  
Vol 9 (13) ◽  
pp. 252 ◽  
Author(s):  
Piyada Wachirawongsakorn ◽  
Tongsai Jamnongkan ◽  
Mohd Talib Latif

<p>Vetiver grass and it usages have been widely investigated in many researches as the preferred plant species due to its known efficiency, low cost, the ease of availability and spread. This research aimed to use four different vetiver grass (<em>Vetiveria zizanioides</em>) ecotypes to remove cyanide (CN<sup>-</sup>)-contaminated water for improve its quality. Growth capability, tolerance and removal efficiency were evaluated. The results showed that the vetiver grass had a 100% survival rate for one month after planting. Songkhlar3 had the longest leaves, followed by Surat-Thani, Sri Lanka and Monto, respectively. Root lengths of all ecotypes showed no significant differences (p ≤ 0.05). All vetiver grass ecotypes could potentially purify CN<sup>-</sup>-contaminated water at lower concentrations of ≤ 35 mg CN<sup>-</sup>/L. The Monto ecotype had the highest CN<sup>-</sup> removal efficiency at all CN<sup>-</sup> concentration levels, showing 100% CN<sup>-</sup> removal from the 5-45 mg CN<sup>-</sup>/L contaminated water samples within 2-5 weeks growth. The tolerance of vetiver grass to CN<sup>-</sup> was a more important factor than growth rate when selecting a vetiver grass ecotype for CN<sup>-</sup> phytoremediation.</p>