scholarly journals Impact of twisting high-performance polyethylene fibre bundle reinforcements on the mechanical characteristics of high-strength concrete

2019 ◽  
Vol 69 (334) ◽  
pp. 184
Author(s):  
Y. Zhang ◽  
L. Yan ◽  
S. Wang ◽  
M. Xu

The quasi-static and dynamic mechanical behaviours of the concrete reinforced by twisting ultra-high molecular weight polyethylene (UHMWPE) fibre bundles with different volume fractions have been investigated. It was indicated that the improved mixing methodology and fibre geometry guaranteed the uniform distribution of fibres in concrete matrix. The UHMWPE fibres significantly enhanced the splitting tensile strength and residual compressive strength of concrete. The discussions on the key property parameters showed that the UHMWPE fibre reinforced concrete behaved tougher than the plain concrete. Owing to the more uniform distribution of fibres and higher bonding strength at fibre/matrix interface, the UHMWPE fibre with improved geometry enhanced the quasi-static splitting tensile strength and compressive strength of concrete more significantly than the other fibres. The dynamic compression tests demonstrated that the UHMWPE fibre reinforced concrete had considerable strain rate dependency. The bonding between fibres and concrete matrix contributed to the strength enhancement under low strain-rate compression.

2021 ◽  
Vol 15 (1) ◽  
pp. 81-92
Author(s):  
Constantinos B. Demakos ◽  
Constantinos C. Repapis ◽  
Dimitros P. Drivas

Aims: The aim of this paper is to investigate the influence of the volume fraction of fibres, the depth of the beam and the shear span-to-depth ratio on the shear strength of steel fibre reinforced concrete beams. Background: Concrete is a material widely used in structures, as it has high compressive strength and stiffness with low cost manufacturing. However, it presents low tensile strength and ductility. Therefore, through years various materials have been embedded inside it to improve its properties, one of which is steel fibres. Steel fibre reinforced concrete presents improved flexural, tensile, shear and torsional strength and post-cracking ductility. Objective: A better understanding of the shear performance of SFRC could lead to improved behaviour and higher safety of structures subject to high shear forces. Therefore, the influence of steel fibres on shear strength of reinforced concrete beams without transverse reinforcement is experimentally investigated. Methods: Eighteen concrete beams were constructed for this purpose and tested under monotonic four-point bending, six of which were made of plain concrete and twelve of SFRC. Two different aspect ratios of beams, steel fibres volume fractions and shear span-to-depth ratios were selected. Results: During the experimental tests, the ultimate loading, deformation at the mid-span, propagation of cracks and failure mode were detected. From the tests, it was shown that SFRC beams with high volume fractions of fibres exhibited an increased shear capacity. Conclusion: The addition of steel fibres resulted in a slight increase of the compressive strength and a significant increase in the tensile strength of concrete and shear resistance capacity of the beam. Moreover, these beams exhibit a more ductile behaviour. Empirical relations predicting the shear strength capacity of fibre reinforced concrete beams were revised and applied successfully to verify the experimental results obtained in this study.


2019 ◽  
Vol 9 (5) ◽  
pp. 4596-4599 ◽  
Author(s):  
N. Bheel ◽  
R. A. Abbasi ◽  
S. Sohu ◽  
S. A. Abbasi ◽  
A. W. Abro ◽  
...  

This study was undertaken to reduce the usage of cement in concrete where different proportions of tile powder as cement replacement were used. Since in the manufacture of cement an exuberant amount of carbon dioxide is disposed of in the environment, this research aims to curtail the dependence on cement and its production. The objective of this work is to investigate the properties of fresh mix concrete (workability) and hardened concrete (compressive and splitting tensile strength) in concrete with different proportions of 0%, 10%, 20%, 30%, and 40% of tile powder as a cement substitute. In this study, a total of 90 concrete samples were cast with mix proportions of 1:1.5:3, 0.5 water-cement ratio, cured for 7, 14 and 28 days. For determining the compressive strength, cubical samples, with dimensions of 100mm×100mm×100mm, were cast, while for the determination of the splitting tensile strength, cylindrical samples with dimensions of 200mm diameter and 100mm height, were tested after 7, 14, and 28 days. The highest compressive strength of concrete achieved for tile powder concrete was 7.50% at 10% replacement after 28days of curing. The splitting tensile strength got to 10.2% when concrete was replaced with 10% of tile powder and cured for 28 days. It was also shown that with increasing percentage of the tile powder content, the workability of the fresh concrete increases.


2021 ◽  
Author(s):  
Hesham Othman

The next generation of concrete, Ultra-High Performance Fibre Reinforced Concrete (UHP-FRC), exhibits exceptional mechanical characteristics. UHP-FRC has a compressive strength exceeding 150 MPa, tensile strength in the range of 8-12 MPa, and fracture energy of several orders of magnitudes of traditional concrete. The focus of this research is to investigate and analyze the advantage of using UHP - FRC in impact resistance structures. To achieve these goals, two experimental testing programs and major numerical investigations have been conducted. The material experimental investigation has been conducted to determine the effects of strain rate on UHP - FRC. Two parameters are investigated, namely: compressive strength (80, 110, 130, and 150 MPa); and steel fibre content (0, 1, 2, and 3%). Experimental results showed that the rate sensitivity decreases with the increase in the compressive strength ; and the dynamic enhancement of tensile strength is inversely proportional to the fibre content. The structural impact testing program focuses on the dynamic response of full - scale reinforced concrete plates as well as generating precise impact measurements. Twelve reinforced plates with identical dimensions are tested under high-mass low-velocity multi-impacts. The investigated parameters include: concrete type (NSC, HSC, and UHP - FRC), fibre volume content, and steel reinforcement ratio. The results showed that the use of UHP -FRC instead of NSC or HSC is able to change the failure mode from punching to pure flexural; and UHP -FRC containing 3% fibre has superior dynamic properties. For plates with identical steel reinforcement, the total impact energy of UHP-FRC plate containing 3% fibres is double the capacity of UHP - FRC plate containing 2% fibres , and 18 times the capacity of NSC plate. A three-dimensional finite element analysis has been performed using ABAQUS/Explicit to model multi-impacts on RC plates and the applicability is verified using existing experimental data. Concrete damage plasticity (CDP) model is adapted to define UHP - FRC. The CDP constitutive model parameters for the new material are calibrated through a series of parametric studies. Computed responses are sensitive to CDP parameters related to the tension, fracture energy, and expansion properties. The analytical results showed that the existing CDP model can predict the response and crack pattern of UHP - FRC reasonably well.


Polymers ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 4112
Author(s):  
Rajab Abousnina ◽  
Sachindra Premasiri ◽  
Vilive Anise ◽  
Weena Lokuge ◽  
Vanissorn Vimonsatit ◽  
...  

Adding fibers to concrete helps enhance its tensile strength and ductility. Synthetic fibres are preferable to steel ones which suffer from corrosion that reduces their functionality with time. More consideration is given to synthetic fibres as they can be sourced from waste plastics and their incorporation in concrete is considered a new recycling pathway. Thus, this work investigates the potential engineering benefits of a pioneering application using extruded macro polyfibres in concrete. Two different fiber dosages, 4 kg/m3 and 6 kg/m3, were used to investigate their influence based on several physical, mechanical and microstructural tests, including workability, compressive strength, modulus of elasticity, splitting-tensile strength, flexural test, CMOD, pull-out test and porosity. The test results revealed a slight decrease in the workability of the fibre-reinforced concrete, while all the mechanical and microstructural properties were enhanced significantly. It was observed that the compressive, splitting tensile and bonding strength of the concrete with 6 kg/m3 fibre dosage increased by 19.4%, 41.9% and 17.8% compared to the plain concrete specimens, respectively. Although there was no impact of the fibres on the modulus of rupture, they significantly increased the toughness, resulting in a progressive type of failure instead of the sudden and brittle type. Moreover, the macroporosity was reduced by the fibre addition, thus increasing the concrete compressive strength. Finally, simplified empirical formulas were developed to predict the mechanical properties of the concrete with fibre addition. The outcome of this study will help to increase the implementation of the recycled plastic waste in concrete mix design and promote a circular economy in the waste industry.


2014 ◽  
Vol 941-944 ◽  
pp. 695-700
Author(s):  
Xiao Yan Song ◽  
Pei Wen Zhang

Finite element analysis is carried out on the dynamic splitting tensile mechanical properties of reinforced concrete with LS-DYNA. The impact of strain rate and reinforcement ratio on the dynamic tensile strength and failure mode of reinforced concrete is considered in the calculation. The result shows that the form of reinforcement and reinforcement ratio has a greater impact on the failure mode and tensile strength of concrete. The dynamic splitting tensile strength of reinforced concrete has a certain strain rate effect and its splitting tensile strength increases with the strain rate; the splitting tensile strength of reinforced concrete also increases with its reinforcement ratio.


1985 ◽  
Vol 64 ◽  
Author(s):  
Parviz Soroushian ◽  
Ki-Bong Choi ◽  
Gung Fu

ABSTRACTResults of dynamic tensile strength tests of concrete, produced by the authors and other investigators, were used to study the effects of strain rate on the tensile strength of concrete. The influence of moisture content and compressive strength of concrete, and type of test (splitting tension, flexure, or direct tension) on the strain rate-sensitivity of the tensile strength were evaluated. An empirically developed expression is presented for the dynamic-to-static ratio of concrete tensile strength in terms of the rate of straining.


2021 ◽  
Vol 350 ◽  
pp. 00008
Author(s):  
Alena Sadouskaya ◽  
Syarhei Leanovich ◽  
Neli Budrevich ◽  
Elena Polonina

There are two most popular approaches to determining the compressive strength of concrete: testing cubes, testing cylinders. The use of different samples gives different results, which are intended to characterize one parameter of the material compressive strength. The article discusses a general approach to determining the compressive strength of cylinders and cubes. The analysis of the factors influencing the transition coefficients when testing the cylinder samples with the ratio of height to diameter is less than 2. The results of testing cubes and cylinders for compression made of fiber-reinforced concrete are presented.


This study presents the experimental investigation carried out to study the mechanical properties of concrete with and without the addition of fibres to it.d Concrete is the most consumed material in the world which has the property of strong in compression and weak in tension. Also plain concrete possess very limited ductility and little resistance to cracking. Hence fibres are introduced in the concrete to improve the tensile strength & brittleness of the concrete. These fibres which are closely spaced and dispersed uniformly in the concrete arrest the micro and macro cracks and improve the tensile strength of concrete. Concrete admixed with such fibres are known as Fibre Reinforced Concrete. The combination of two (or) more fibres called as Hybridization is carried out in this work. M25 grade concrete is designed as per IS 10262:2009 with the volume fraction of 0-1.5%. The workability of the concrete is affected due to the addition of fibres and hence super plasticizers are added to the concrete. The fibres considered for the study are (i) Crimped Steel Fibre (0-1.5%) and (ii) Shortcut Glass Fibre (0.1-0.2%). The behaviour of the hybrid fibre reinforced concrete is investigated by conducting compressive strength test on cube specimen of size 150mmx150mmx150mm and split tensile strength test on cylinder specimen of size 150mm diameter and 300mm height. From the experimental results, the optimum fibre combinations for maximum compressive strength and spilt tensile strength of concrete are identified.


2020 ◽  
Vol 2020 ◽  
pp. 1-14
Author(s):  
Shi Hu ◽  
Ying Xu

To investigate whether the compound modification means which mixes modified Polyvinyl chloride (PVC) aggregate and polypropylene fiber in concrete could gain “positive hybrid effect” and cope with more sophisticated engineering circumstances, four groups of test specimens were prepared: concrete doped with unmodified PVC aggregate, concrete doped with modified PVC aggregate, concrete doped with unmodified PVC aggregate and polypropylene fiber, and concrete doped with modified PVC aggregate and polypropylene fiber. The fiber content is 0.9 kg/m3, the modified solution content is 1 mol/L NaOH, and the replacement amount of PVC fine aggregate in replacement sand is 0%, 5%, 10%, 20%, and 30%. Mechanical property and durability tests were carried out to compare and analyze the measured compressive strength, splitting tensile strength, flexural tensile strength, water absorption rate, and impact failure energy. Moreover, scanning electron microscopy and XRD diffraction were used to analyze micromorphology and crystal structure of concrete. The test results demonstrate that as the content of PVC aggregate increases, the compressive strength, splitting tensile strength, and flexural tensile strength of the concrete decrease significantly, while the brittleness is improved. Meanwhile, the water absorption rate increases and the impact resistance shows an approximately linear increase trend. Under the same content of PVC aggregate, the most effective way to improve compressive strength is to use modified PVC aggregate. The rapid decrease of compressive strength caused by PVC aggregate can be effectively delayed by doping polypropylene fiber and modified PVC aggregate. Adding polypropylene fiber or using the modified PVC aggregate can improve the brittleness, tensile strength, flexural tensile strength, and impact resistance, but they have different modification and reinforcement effects. The concrete prepared by doping polypropylene fiber and modified PVC aggregate has better performance in tensile strength, flexural tensile strength, brittleness, and impact resistance, and the water absorption and the compressive strength of the concrete are enhanced compared with the normal group. Therefore, composite modified reinforced concrete doped with modified PVC aggregate-polypropylene fiber has broad application prospects.


Sign in / Sign up

Export Citation Format

Share Document