scholarly journals Diagnostic accuracy of the International HIV Dementia Scale and HIV Dementia Scale: A meta-analysis

2012 ◽  
Vol 4 (4) ◽  
pp. 665-668 ◽  
Author(s):  
XUEYING HU ◽  
YANG ZHOU ◽  
JIANXIONG LONG ◽  
QIMING FENG ◽  
RENSHENG WANG ◽  
...  
Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1124
Author(s):  
Elena Cecilia Rosca ◽  
Philippe Tadger ◽  
Amalia Cornea ◽  
Raluca Tudor ◽  
Cristian Oancea ◽  
...  

The present study aims to systematically review the evidence on the accuracy of the International HIV Dementia Scale (IHDS) test for diagnosing human immunodeficiency virus (HIV)-associated neurocognitive disorders (HAND) and outline the quality and quantity of research evidence available on the accuracy of IHDS in people living with HIV. We conducted a systematic literature review, searching five databases from inception until July 2020. We extracted dichotomized positive and negative test results at various thresholds and calculated the sensitivity and specificity of IHDS. Quality assessment was performed according to the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria. Fifteen cross-sectional studies, published between 2011 and 2018, met the inclusion criteria for meta-analysis. Overall, 3760 patients were included, but most studies recruited small samples. We assessed most studies as being applicable to the review question, though we had concerns about the selection of participants in three studies. The accuracy of IHDS was investigated at thirteen cut-off points (scores 6–12). The threshold of 10 is the most useful for optimal HAND screening (including asymptomatic neurocognitive disorder, symptomatic HAND, and HIV-associated dementia) with fair diagnostic accuracy.


VASA ◽  
2016 ◽  
Vol 45 (2) ◽  
pp. 149-154 ◽  
Author(s):  
Jie Li ◽  
Lei Feng ◽  
Jiangbo Li ◽  
Jian Tang

Abstract. Background: The aim of this meta-analysis was to evaluate the diagnostic accuracy of magnetic resonance angiography (MRA) for acute pulmonary embolism (PE). Methods: A systematic literature search was conducted that included studies from January 2000 to August 2015 using the electronic databases PubMed, Embase and Springer link. The summary receiver operating characteristic (SROC) curve, sensitivity, specificity, positive likelihood ratios (PLR), negative likelihood ratios (NLR), and diagnostic odds ratio (DOR) as well as the 95 % confidence intervals (CIs) were calculated to evaluate the diagnostic accuracy of MRA for acute PE. Meta-disc software version 1.4 was used to analyze the data. Results: Five studies were included in this meta-analysis. The pooled sensitivity (86 %, 95 % CI: 81 % to 90 %) and specificity (99 %, 95 % CI: 98 % to 100 %) demonstrated that MRA diagnosis had limited sensitivity and high specificity in the detection of acute PE. The pooled estimate of PLR (41.64, 95 % CI: 17.97 to 96.48) and NLR (0.17, 95 % CI: 0.11 to 0.27) provided evidence for the low missed diagnosis and misdiagnosis rates of MRA for acute PE. The high diagnostic accuracy of MRA for acute PE was demonstrated by the overall DOR (456.51, 95 % CI: 178.38 - 1168.31) and SROC curves (AUC = 0.9902 ± 0.0061). Conclusions: MRA can be used for the diagnosis of acute PE. However, due to limited sensitivity, MRA cannot be used as a stand-alone test to exclude acute PE.


2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


Sign in / Sign up

Export Citation Format

Share Document