scholarly journals An Integrative Evaluation of the Efficacy of a Directional Microphone and Noise-Reduction Algorithm under Realistic Signal-to-Noise Ratios

2020 ◽  
Vol 31 (04) ◽  
pp. 262-270
Author(s):  
Francis Kuk ◽  
Christopher Slugocki ◽  
Petri Korhonen

Abstract Background Many studies on the efficacy of directional microphones (DIRMs) and noise-reduction (NR) algorithms were not conducted under realistic signal-to-noise ratio (SNR) conditions. A Repeat-Recall Test (RRT) was developed previously to partially address this issue. Purpose This study evaluated whether the RRT could provide a more comprehensive understanding of the efficacy of a DIRM and NR algorithm under realistic SNRs. Possible interaction with listener working memory capacity (WMC) was assessed. Research Design This study uses a double-blind, within-subject repeated measures design. Study Sample Nineteen listeners with a moderate degree of hearing loss participated. Data Collection and Analysis The RRT was administered with participants wearing the study hearing aids (HAs) under two microphones (omnidirectional versus directional) by two NR (on versus off) conditions. Speech was presented from 0° at 75 dB SPL and a continuous noise from 180° at SNRs of 0, 5, 10, and 15 dB. The order of SNR and HA conditions was counterbalanced across listeners. Each test condition was completed twice in two 2-hour sessions separated by one month. Results The recall scores of listeners were used to group listeners into good and poor WMC groups. Analysis using linear mixed-effects models revealed significant effects of context, SNR, and microphone for all four measures (repeat, recall, listening effort, and tolerable time). NR was only significant on the listening effort scale in the DIRM mode at an SNR of 5 dB. Listeners with good WMC performed better on all measures of the RRT and benefitted more from context. Although DIRM benefitted listeners with good and poor WMC, the benefits differed by context and SNR. Conclusions The RRT confirmed the efficacy of DIRM and NR on several outcome measures under realistic SNRs. It also highlighted interactions between WMC and sentence context on feature efficacy.

Author(s):  
Francis Kuk ◽  
Christopher Slugocki ◽  
Petri Korhonen

Background: Many studies on the efficacy of directional microphones (DIRMs) and noise reduction (NR)algorithms were not conducted under realistic signal-to-noise ratio (SNR) conditions. A Repeat–RecallTest (RRT) was developed previously to partially address this issue.<br />Purpose: This study evaluated whether the RRT could provide a more comprehensive understanding ofthe efficacy of a DIRM and NR algorithm under realistic SNRs. Possible interaction with listener workingmemory capacity (WMC) was assessed.<br />Research Design: This study uses a double-blind, within-subject repeated measures design.<br />Study Sample: Nineteen listeners with a moderate degree of hearing loss participated.<br />Data Collection and Analysis: The RRT was administered with participants wearing the study hearingaids (HAs) under two microphones (omnidirectional versus directional) by two NR (on versus off) conditions.Speech was presented from 0° at 75 dB SPL and a continuous noise from 180° at SNRs of 0, 5,10, and 15 dB. The order of SNR and HA conditions was counterbalanced across listeners. Each testcondition was completed twice in two 2-hour sessions separated by one month.<br />Results: The recall scores of listeners were used to group listeners into good and poor WMC groups.Analysis using linear mixed-effects models revealed significant effects of context, SNR, and microphonefor all four measures (repeat, recall, listening effort, and tolerable time). NR was only significant on thelistening effort scale in the DIRM mode at an SNR of 5 dB. Listeners with good WMC performed better onall measures of the RRT and benefitted more from context. Although DIRM benefitted listeners with goodand poor WMC, the benefits differed by context and SNR.<br />Conclusions: The RRT confirmed the efficacy of DIRM and NR on several outcome measures underrealistic SNRs. It also highlighted interactions between WMC and sentence context on feature efficacy.<br />


Author(s):  
Francis Kuk ◽  
Christopher Slugocki ◽  
Petri Korhonen

Abstract Background The effect of context on speech processing has been studied using different speech materials and response criteria. The Repeat-Recall Test (RRT) evaluates listener performance using high context (HC) and low context (LC) sentences; this may offer another platform for studying context use (CU). Objective This article aims to evaluate if the RRT may be used to study how different signal-to-noise ratios (SNRs), hearing aid technologies (directional microphone and noise reduction), and listener working memory capacities (WMCs) interact to affect CU on the different measures of the RRT. Design Double-blind, within-subject repeated measures design. Study Sample Nineteen listeners with a mild-to-moderately severe hearing loss. Data Collection The RRT was administered with participants wearing the study hearing aids under two microphone (omnidirectional vs. directional) by two noise reduction (on vs. off) conditions. Speech was presented from 0 degree at 75 dB sound pressure level and a continuous speech-shaped noise from 180 degrees at SNRs of 0, 5, 10, and 15 dB. The order of SNR and hearing aid conditions was counterbalanced across listeners. Each test condition was completed twice in two 2-hour sessions separated by 1 month. Results CU was calculated as the difference between HC and LC sentence scores for each outcome measure (i.e., repeat, recall, listening effort, and tolerable time). For all outcome measures, repeated measures analyses of variance revealed that CU was significantly affected by the SNR of the test conditions. For repeat, recall, and listening effort measures, these effects were qualified by significant two-way interactions between SNR and microphone mode. In addition, the WMC group significantly affected CU during recall and rating of listening effort, the latter of which was qualified by an interaction between the WMC group and SNR. Listener WMC affected CU on estimates of tolerable time as qualified by significant two-way interactions between SNR and microphone mode. Conclusion The study supports use of the RRT as a tool for measuring how listeners use sentence context to aid in speech processing. The degree to which context influenced scores on each outcome measure of the RRT was found to depend on complex interactions between the SNR of the listening environment, hearing aid features, and the WMC of the listeners.


2019 ◽  
Vol 30 (07) ◽  
pp. 590-606 ◽  
Author(s):  
Francis Kuk ◽  
Chris Slugocki ◽  
Petri Korhonen ◽  
Eric Seper ◽  
Ole Hau

AbstractIt has been suggested that hearing-impaired listeners with a good working memory (WM) should be fitted with a compression system using short time constants (i.e., fast-acting compression [FAC]), whereas those with a poorer WM should be fitted with a longer time constant (i.e., slow-acting compression [SAC]). However, commercial hearing aids (HAs) seldom use a fixed speed of compression.The performance of a variable speed compression (VSC) system relative to a fixed speed compressor (FAC and SAC) on measures of speech intelligibility, recall, and subjective report of listening effort and tolerable time was evaluated. The potential interaction with the listeners’ WM capacity (WMC) was also examined.A double-blinded, repeated measures design.Seventeen HA wearers (16 with greater than one year HA experience) with a bilaterally symmetrical, mild to moderately severe sensorineural hearing loss participated in the study.Participants wore the study HAs at three compression speeds (FAC, SAC, and VSC). Each listener was evaluated on the Office of Research in Clinical Amplification-nonsense syllable test (NST) at 50 dB SPL (signal-to-noise ratio [SNR] = +15 dB), 65 dB SPL (SNR = +5 dB), 80 dB SPL (SNR = 0 dB), and a split (80 dB SPL–50 dB SPL) condition. Listeners were also evaluated on a Repeat Recall Test (RRT), where they had to repeat six short sentences (both high- and low-context sentences) after each was presented. Listeners recalled target words in all six sentences after they were presented. They also rated their listening effort and the amount of time they would tolerate listening under the specific condition. RRT sentences were presented at 75 dB SPL in quiet, as well as SNR = 0, 5, 10, and 15 dB. A Reading Span Test (RST) was also administered to assess listeners’ WMC. Analysis of variance using RST scores as a covariate was used to examine differences in listener performance among compressor speeds.Listener performance on the NST was similar among all three compression speeds at 50, 65, and 80 dB SPL. Performance with FAC was significantly better than SAC for the split condition; however, performance did not differ between FAC and VSC or between SAC and VSC. Performance on the NST was not affected by listeners’ RST scores. On the RRT, there was no effect of compressor speed on measures of repeat, recall, listening effort, and tolerable time. However, VSC resulted in significantly lower (better) speech reception threshold at the 85% correct recognition criterion (SRT85) than FAC and SAC. Listener RST scores significantly affected recall performance on the RRT but did not affect SRT85, repeat, listening effort, or tolerable time.These results suggest that the VSC, FAC, and SAC yield similar performance in most but not all test conditions. FAC outperforms SAC, where the stimulus levels change abruptly (i.e., split condition). The VSC yields a lower SRT85 than a fixed compression speed at a moderately high level with a favorable SNR. There is no interaction between compression speed and the participants’ WMC.


2013 ◽  
Vol 24 (10) ◽  
pp. 980-991 ◽  
Author(s):  
Kristi Oeding ◽  
Michael Valente

Background: In the past, bilateral contralateral routing of signals (BICROS) amplification incorporated omnidirectional microphones on the transmitter and receiver sides and some models utilized noise reduction (NR) on the receiver side. Little research has examined the performance of BICROS amplification in background noise. However, previous studies examining contralateral routing of signals (CROS) amplification have reported that the presence of background noise on the transmitter side negatively affected speech recognition. Recently, NR was introduced as a feature on the receiver and transmitter sides of BICROS amplification, which has the potential to decrease the impact of noise on the wanted speech signal by decreasing unwanted noise directed to the transmitter side. Purpose: The primary goal of this study was to examine differences in the reception threshold for sentences (RTS in dB) using the Hearing in Noise Test (HINT) in a diffuse listening environment between unaided and three aided BICROS conditions (no NR, mild NR, and maximum NR) in the Tandem 16 BICROS. A secondary goal was to examine real-world subjective impressions of the Tandem 16 BICROS compared to unaided. Research Design: A randomized block repeated measures single blind design was used to assess differences between no NR, mild NR, and maximum NR listening conditions. Study Sample: Twenty-one adult participants with asymmetric sensorineural hearing loss (ASNHL) and experience with BICROS amplification were recruited from Washington University in St. Louis School of Medicine. Data Collection and Analysis: Participants were fit with the National Acoustic Laboratories’ Nonlinear version 1 prescriptive target (NAL-NL1) with the Tandem 16 BICROS at the initial visit and then verified using real-ear insertion gain (REIG) measures. Participants acclimatized to the Tandem 16 BICROS for 4 wk before returning for final testing. Participants were tested utilizing HINT sentences examining differences in RTS between unaided and three aided listening conditions. Subjective benefit was determined via the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire between the Tandem 16 BICROS and unaided. A repeated measures analysis of variance (ANOVA) was utilized to analyze the results of the HINT and APHAB. Results: Results revealed no significant differences in the RTS between unaided, no NR, mild NR, and maximum NR. Subjective impressions using the APHAB revealed statistically and clinically significant benefit with the Tandem 16 BICROS compared to unaided for the Ease of Communication (EC), Background Noise (BN), and Reverberation (RV) subscales. Conclusions: The RTS was not significantly different between unaided, no NR, mild NR, and maximum NR. None of the three aided listening conditions were significantly different from unaided performance as has been reported for previous studies examining CROS hearing aids. Further, based on comments from participants and previous research studies with conventional hearing aids, manufacturers of BICROS amplification should consider incorporating directional microphones and independent volume controls on the receiver and transmitter sides to potentially provide further improvement in signal-to-noise ratio (SNR) for patients with ASNHL.


2013 ◽  
Vol 24 (08) ◽  
pp. 649-659 ◽  
Author(s):  
Kristy Jones Lowery ◽  
Patrick N. Plyler

Background: Directional microphones (D-Mics) and digital noise reduction (DNR) algorithms are used in hearing aids to reduce the negative effects of background noise on performance. Directional microphones attenuate sounds arriving from anywhere other than the front of the listener while DNR attenuates sounds with physical characteristics of noise. Although both noise reduction technologies are currently available in hearing aids, it is unclear if the use of these technologies in isolation or together affects acceptance of noise and/or preference for the end user when used in various types of background noise. Purpose: The purpose of the research was to determine the effects of D-Mic, DNR, or the combination of D-Mic and DNR on acceptance of noise and preference when listening in various types of background noise. Research Design: An experimental study in which subjects were exposed to a repeated measures design was utilized. Study Sample: Thirty adult listeners with mild sloping to moderately severe sensorineural hearing loss participated (mean age 67 yr). Data Collection and Analysis: Acceptable noise levels (ANLs) were obtained using no noise reduction technologies, D-Mic only, DNR only, and the combination of the two technologies (Combo) for three different background noises (single-talker speech, speech-shaped noise, and multitalker babble) for each listener. In addition, preference rankings of the noise reduction technologies were obtained within each background noise (1 = best, 3 = worst). Results: ANL values were significantly better for each noise reduction technology than baseline; and benefit increased significantly from DNR to D-Mic to Combo. Listeners with higher (worse) baseline ANLs received more benefit from noise reduction technologies than listeners with lower (better) baseline ANLs. Neither ANL values nor ANL benefit values were significantly affected by background noise type; however, ANL benefit with D-Mic and Combo was similar when speech-like noise was present while ANL benefit was greatest for Combo when speech spectrum noise was present. Listeners preferred the hearing aid settings that resulted in the best ANL value. Conclusion: Noise reduction technologies improved ANL for each noise type, and the amount of improvement was related to the baseline ANL value. Improving an ANL with noise reduction technologies is noticeable to listeners, at least when examined in this laboratory setting, and listeners prefer noise reduction technologies that improved their ability to accept noise.


2013 ◽  
Vol 24 (09) ◽  
pp. 845-858 ◽  
Author(s):  
Petri Korhonen ◽  
Francis Kuk ◽  
Chi Lau ◽  
Denise Keenan ◽  
Jennifer Schumacher ◽  
...  

Background: Today's compression hearing aids with noise reduction systems may not manage transient noises effectively because of the short duration of these sounds compared to the onset times of the compressors and/or noise reduction algorithms. Purpose: The current study was designed to evaluate the effect of a transient noise reduction (TNR) algorithm on listening comfort, speech intelligibility in quiet, and preferred wearer gain in the presence of transients. Research Design: A single-blinded, repeated-measures design was used. Study Sample: Thirteen experienced hearing aid users with bilaterally symmetrical (≤7.5 dB) sensorineural hearing loss participated in the study. Results: Speech identification in quiet (no transient noise) was identical between the TNR On and the TNR Off conditions. The participants showed subjective preference for the TNR algorithm when “comfortable listening” was used as the criterion. Participants preferred less gain than the default prescription in the presence of transient noise sounds. However, the preferred gain was 2.9 dB higher when the TNR was activated than when it was deactivated. This translated to 12.1% improvement in phoneme identification over the TNR Off condition for soft speech. Conclusions: This study demonstrated that the use of the TNR algorithm would not negatively affect speech identification. The results also suggested that this algorithm may improve listening comfort in the presence of transient noise sounds and ensure consistent use of prescribed gain. Such an algorithm may ensure more consistent audibility across listening environments.


2010 ◽  
Vol 21 (08) ◽  
pp. 546-557 ◽  
Author(s):  
Kristi Oeding ◽  
Michael Valente ◽  
Jessica Kerckhoff

Background: Patients with unilateral sensorineural hearing loss (USNHL) experience great difficulty listening to speech in noisy environments. A directional microphone (DM) could potentially improve speech recognition in this difficult listening environment. It is well known that DMs in behind-the-ear (BTE) and custom hearing aids can provide a greater signal-to-noise ratio (SNR) in comparison to an omnidirectional microphone (OM) to improve speech recognition in noise for persons with hearing impairment. Studies examining the DM in bone anchored auditory osseointegrated implants (Baha), however, have been mixed, with little to no benefit reported for the DM compared to an OM. Purpose: The primary purpose of this study was to determine if there are statistically significant differences in the mean reception threshold for sentences (RTS in dB) in noise between the OM and DM in the Baha® Divino™. The RTS of these two microphone modes was measured utilizing two loudspeaker arrays (speech from 0° and noise from 180° or a diffuse eight-loudspeaker array) and with the better ear open or closed with an earmold impression and noise attenuating earmuff. Subjective benefit was assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) to compare unaided and aided (Divino OM and DM combined) problem scores. Research Design: A repeated measures design was utilized, with each subject counterbalanced to each of the eight treatment levels for three independent variables: (1) microphone (OM and DM), (2) loudspeaker array (180° and diffuse), and (3) better ear (open and closed). Study Sample: Sixteen subjects with USNHL currently utilizing the Baha were recruited from Washington University's Center for Advanced Medicine and the surrounding area. Data Collection and Analysis: Subjects were tested at the initial visit if they entered the study wearing the Divino or after at least four weeks of acclimatization to a loaner Divino. The RTS was determined utilizing Hearing in Noise Test (HINT) sentences in the R-Space™ system, and subjective benefit was determined utilizing the APHAB. A three-way repeated measures analysis of variance (ANOVA) and a paired samples t-test were utilized to analyze results of the HINT and APHAB, respectively. Results: Results revealed statistically significant differences within microphone (p < 0.001; directional advantage of 3.2 dB), loudspeaker array (p = 0.046; 180° advantage of 1.1 dB), and better ear conditions (p < 0.001; open ear advantage of 4.9 dB). Results from the APHAB revealed statistically and clinically significant benefit for the Divino relative to unaided on the subscales of Ease of Communication (EC) (p = 0.037), Background Noise (BN) (p < 0.001), and Reverberation (RV) (p = 0.005). Conclusions: The Divino's DM provides a statistically significant improvement in speech recognition in noise compared to the OM for subjects with USNHL. Therefore, it is recommended that audiologists consider selecting a Baha with a DM to provide improved speech recognition performance in noisy listening environments.


2015 ◽  
Vol 26 (01) ◽  
pp. 093-100 ◽  
Author(s):  
Jace Wolfe ◽  
Erin Schafer ◽  
Emily Mills ◽  
Andrew John ◽  
Mary Hudson ◽  
...  

Background: There is a paucity of published studies examining how children with hearing loss understand speech over the telephone. Previous studies on adults with hearing aids have suggested that adults with bilateral hearing aids experience significant difficulty recognizing speech on the telephone when listening with one ear, but the provision of telephone input to both ears substantially improved speech understanding. Purpose: The objectives of this study were to measure speech recognition in quiet and in noise for a group of older children with hearing loss over the telephone and to evaluate the effects of binaural hearing (e.g., DuoPhone) on speech recognition over the telephone. Research Design: A cross-sectional, repeated-measures design was used in this study. Study Sample: A total of 14 children, ages 6–14 yr, participated in the study. Participants were obtained using convenience sampling from a nonprofit clinic population. Intervention: Speech recognition in quiet and in noise with binaural versus monaural telephone input was compared in pediatric participants. Data Collection and Analysis: Monosyllabic word recognition was assessed in quiet and classroom noise set at 50 dBA in conditions with monaural and binaural (DuoPhone) telephone input. Results: The children’s speech recognition in quiet and in noise was significantly better with binaural telephone input relative to monaural telephone input. Conclusions: To obtain optimal performance on the telephone, the following considerations may apply: (1) use of amplification with binaural streaming capabilities (e.g., DuoPhone), (2) counseling of family and children on how to best use the telephone, (3) provision of telecoil with microphone attenuation for improved signal-to-noise ratio, and (4) use of probe tube measures to verify the appropriateness of the telephone programs.


2021 ◽  
Vol 25 ◽  
pp. 233121652110144
Author(s):  
Ilja Reinten ◽  
Inge De Ronde-Brons ◽  
Rolph Houben ◽  
Wouter Dreschler

Single microphone noise reduction (NR) in hearing aids can provide a subjective benefit even when there is no objective improvement in speech intelligibility. A possible explanation lies in a reduction of listening effort. Previously, we showed that response times (a proxy for listening effort) to an auditory-only dual-task were reduced by NR in normal-hearing (NH) listeners. In this study, we investigate if the results from NH listeners extend to the hearing-impaired (HI), the target group for hearing aids. In addition, we assess the relevance of the outcome measure for studying and understanding listening effort. Twelve HI subjects were asked to sum two digits of a digit triplet in noise. We measured response times to this task, as well as subjective listening effort and speech intelligibility. Stimuli were presented at three signal-to-noise ratios (SNR; –5, 0, +5 dB) and in quiet. Stimuli were processed with ideal or nonideal NR, or unprocessed. The effect of NR on response times in HI listeners was significant only in conditions where speech intelligibility was also affected (–5 dB SNR). This is in contrast to the previous results with NH listeners. There was a significant effect of SNR on response times for HI listeners. The response time measure was reasonably correlated ( R142 = 0.54) to subjective listening effort and showed a sufficient test–retest reliability. This study thus presents an objective, valid, and reliable measure for evaluating an aspect of listening effort of HI listeners.


Sign in / Sign up

Export Citation Format

Share Document