scholarly journals Evaluation of the Efficacy of a Dual Variable Speed Compressor over a Single Fixed Speed Compressor

2019 ◽  
Vol 30 (07) ◽  
pp. 590-606 ◽  
Author(s):  
Francis Kuk ◽  
Chris Slugocki ◽  
Petri Korhonen ◽  
Eric Seper ◽  
Ole Hau

AbstractIt has been suggested that hearing-impaired listeners with a good working memory (WM) should be fitted with a compression system using short time constants (i.e., fast-acting compression [FAC]), whereas those with a poorer WM should be fitted with a longer time constant (i.e., slow-acting compression [SAC]). However, commercial hearing aids (HAs) seldom use a fixed speed of compression.The performance of a variable speed compression (VSC) system relative to a fixed speed compressor (FAC and SAC) on measures of speech intelligibility, recall, and subjective report of listening effort and tolerable time was evaluated. The potential interaction with the listeners’ WM capacity (WMC) was also examined.A double-blinded, repeated measures design.Seventeen HA wearers (16 with greater than one year HA experience) with a bilaterally symmetrical, mild to moderately severe sensorineural hearing loss participated in the study.Participants wore the study HAs at three compression speeds (FAC, SAC, and VSC). Each listener was evaluated on the Office of Research in Clinical Amplification-nonsense syllable test (NST) at 50 dB SPL (signal-to-noise ratio [SNR] = +15 dB), 65 dB SPL (SNR = +5 dB), 80 dB SPL (SNR = 0 dB), and a split (80 dB SPL–50 dB SPL) condition. Listeners were also evaluated on a Repeat Recall Test (RRT), where they had to repeat six short sentences (both high- and low-context sentences) after each was presented. Listeners recalled target words in all six sentences after they were presented. They also rated their listening effort and the amount of time they would tolerate listening under the specific condition. RRT sentences were presented at 75 dB SPL in quiet, as well as SNR = 0, 5, 10, and 15 dB. A Reading Span Test (RST) was also administered to assess listeners’ WMC. Analysis of variance using RST scores as a covariate was used to examine differences in listener performance among compressor speeds.Listener performance on the NST was similar among all three compression speeds at 50, 65, and 80 dB SPL. Performance with FAC was significantly better than SAC for the split condition; however, performance did not differ between FAC and VSC or between SAC and VSC. Performance on the NST was not affected by listeners’ RST scores. On the RRT, there was no effect of compressor speed on measures of repeat, recall, listening effort, and tolerable time. However, VSC resulted in significantly lower (better) speech reception threshold at the 85% correct recognition criterion (SRT85) than FAC and SAC. Listener RST scores significantly affected recall performance on the RRT but did not affect SRT85, repeat, listening effort, or tolerable time.These results suggest that the VSC, FAC, and SAC yield similar performance in most but not all test conditions. FAC outperforms SAC, where the stimulus levels change abruptly (i.e., split condition). The VSC yields a lower SRT85 than a fixed compression speed at a moderately high level with a favorable SNR. There is no interaction between compression speed and the participants’ WMC.

2020 ◽  
Vol 31 (04) ◽  
pp. 262-270
Author(s):  
Francis Kuk ◽  
Christopher Slugocki ◽  
Petri Korhonen

Abstract Background Many studies on the efficacy of directional microphones (DIRMs) and noise-reduction (NR) algorithms were not conducted under realistic signal-to-noise ratio (SNR) conditions. A Repeat-Recall Test (RRT) was developed previously to partially address this issue. Purpose This study evaluated whether the RRT could provide a more comprehensive understanding of the efficacy of a DIRM and NR algorithm under realistic SNRs. Possible interaction with listener working memory capacity (WMC) was assessed. Research Design This study uses a double-blind, within-subject repeated measures design. Study Sample Nineteen listeners with a moderate degree of hearing loss participated. Data Collection and Analysis The RRT was administered with participants wearing the study hearing aids (HAs) under two microphones (omnidirectional versus directional) by two NR (on versus off) conditions. Speech was presented from 0° at 75 dB SPL and a continuous noise from 180° at SNRs of 0, 5, 10, and 15 dB. The order of SNR and HA conditions was counterbalanced across listeners. Each test condition was completed twice in two 2-hour sessions separated by one month. Results The recall scores of listeners were used to group listeners into good and poor WMC groups. Analysis using linear mixed-effects models revealed significant effects of context, SNR, and microphone for all four measures (repeat, recall, listening effort, and tolerable time). NR was only significant on the listening effort scale in the DIRM mode at an SNR of 5 dB. Listeners with good WMC performed better on all measures of the RRT and benefitted more from context. Although DIRM benefitted listeners with good and poor WMC, the benefits differed by context and SNR. Conclusions The RRT confirmed the efficacy of DIRM and NR on several outcome measures under realistic SNRs. It also highlighted interactions between WMC and sentence context on feature efficacy.


2013 ◽  
Vol 24 (09) ◽  
pp. 845-858 ◽  
Author(s):  
Petri Korhonen ◽  
Francis Kuk ◽  
Chi Lau ◽  
Denise Keenan ◽  
Jennifer Schumacher ◽  
...  

Background: Today's compression hearing aids with noise reduction systems may not manage transient noises effectively because of the short duration of these sounds compared to the onset times of the compressors and/or noise reduction algorithms. Purpose: The current study was designed to evaluate the effect of a transient noise reduction (TNR) algorithm on listening comfort, speech intelligibility in quiet, and preferred wearer gain in the presence of transients. Research Design: A single-blinded, repeated-measures design was used. Study Sample: Thirteen experienced hearing aid users with bilaterally symmetrical (≤7.5 dB) sensorineural hearing loss participated in the study. Results: Speech identification in quiet (no transient noise) was identical between the TNR On and the TNR Off conditions. The participants showed subjective preference for the TNR algorithm when “comfortable listening” was used as the criterion. Participants preferred less gain than the default prescription in the presence of transient noise sounds. However, the preferred gain was 2.9 dB higher when the TNR was activated than when it was deactivated. This translated to 12.1% improvement in phoneme identification over the TNR Off condition for soft speech. Conclusions: This study demonstrated that the use of the TNR algorithm would not negatively affect speech identification. The results also suggested that this algorithm may improve listening comfort in the presence of transient noise sounds and ensure consistent use of prescribed gain. Such an algorithm may ensure more consistent audibility across listening environments.


2021 ◽  
Vol 42 (03) ◽  
pp. 260-281
Author(s):  
Asger Heidemann Andersen ◽  
Sébastien Santurette ◽  
Michael Syskind Pedersen ◽  
Emina Alickovic ◽  
Lorenz Fiedler ◽  
...  

AbstractHearing aids continue to acquire increasingly sophisticated sound-processing features beyond basic amplification. On the one hand, these have the potential to add user benefit and allow for personalization. On the other hand, if such features are to benefit according to their potential, they require clinicians to be acquainted with both the underlying technologies and the specific fitting handles made available by the individual hearing aid manufacturers. Ensuring benefit from hearing aids in typical daily listening environments requires that the hearing aids handle sounds that interfere with communication, generically referred to as “noise.” With this aim, considerable efforts from both academia and industry have led to increasingly advanced algorithms that handle noise, typically using the principles of directional processing and postfiltering. This article provides an overview of the techniques used for noise reduction in modern hearing aids. First, classical techniques are covered as they are used in modern hearing aids. The discussion then shifts to how deep learning, a subfield of artificial intelligence, provides a radically different way of solving the noise problem. Finally, the results of several experiments are used to showcase the benefits of recent algorithmic advances in terms of signal-to-noise ratio, speech intelligibility, selective attention, and listening effort.


Author(s):  
Francis Kuk ◽  
Christopher Slugocki ◽  
Petri Korhonen

Abstract Background The effect of context on speech processing has been studied using different speech materials and response criteria. The Repeat-Recall Test (RRT) evaluates listener performance using high context (HC) and low context (LC) sentences; this may offer another platform for studying context use (CU). Objective This article aims to evaluate if the RRT may be used to study how different signal-to-noise ratios (SNRs), hearing aid technologies (directional microphone and noise reduction), and listener working memory capacities (WMCs) interact to affect CU on the different measures of the RRT. Design Double-blind, within-subject repeated measures design. Study Sample Nineteen listeners with a mild-to-moderately severe hearing loss. Data Collection The RRT was administered with participants wearing the study hearing aids under two microphone (omnidirectional vs. directional) by two noise reduction (on vs. off) conditions. Speech was presented from 0 degree at 75 dB sound pressure level and a continuous speech-shaped noise from 180 degrees at SNRs of 0, 5, 10, and 15 dB. The order of SNR and hearing aid conditions was counterbalanced across listeners. Each test condition was completed twice in two 2-hour sessions separated by 1 month. Results CU was calculated as the difference between HC and LC sentence scores for each outcome measure (i.e., repeat, recall, listening effort, and tolerable time). For all outcome measures, repeated measures analyses of variance revealed that CU was significantly affected by the SNR of the test conditions. For repeat, recall, and listening effort measures, these effects were qualified by significant two-way interactions between SNR and microphone mode. In addition, the WMC group significantly affected CU during recall and rating of listening effort, the latter of which was qualified by an interaction between the WMC group and SNR. Listener WMC affected CU on estimates of tolerable time as qualified by significant two-way interactions between SNR and microphone mode. Conclusion The study supports use of the RRT as a tool for measuring how listeners use sentence context to aid in speech processing. The degree to which context influenced scores on each outcome measure of the RRT was found to depend on complex interactions between the SNR of the listening environment, hearing aid features, and the WMC of the listeners.


Author(s):  
Francis Kuk ◽  
Christopher Slugocki ◽  
Petri Korhonen

Background: Many studies on the efficacy of directional microphones (DIRMs) and noise reduction (NR)algorithms were not conducted under realistic signal-to-noise ratio (SNR) conditions. A Repeat–RecallTest (RRT) was developed previously to partially address this issue.<br />Purpose: This study evaluated whether the RRT could provide a more comprehensive understanding ofthe efficacy of a DIRM and NR algorithm under realistic SNRs. Possible interaction with listener workingmemory capacity (WMC) was assessed.<br />Research Design: This study uses a double-blind, within-subject repeated measures design.<br />Study Sample: Nineteen listeners with a moderate degree of hearing loss participated.<br />Data Collection and Analysis: The RRT was administered with participants wearing the study hearingaids (HAs) under two microphones (omnidirectional versus directional) by two NR (on versus off) conditions.Speech was presented from 0° at 75 dB SPL and a continuous noise from 180° at SNRs of 0, 5,10, and 15 dB. The order of SNR and HA conditions was counterbalanced across listeners. Each testcondition was completed twice in two 2-hour sessions separated by one month.<br />Results: The recall scores of listeners were used to group listeners into good and poor WMC groups.Analysis using linear mixed-effects models revealed significant effects of context, SNR, and microphonefor all four measures (repeat, recall, listening effort, and tolerable time). NR was only significant on thelistening effort scale in the DIRM mode at an SNR of 5 dB. Listeners with good WMC performed better onall measures of the RRT and benefitted more from context. Although DIRM benefitted listeners with goodand poor WMC, the benefits differed by context and SNR.<br />Conclusions: The RRT confirmed the efficacy of DIRM and NR on several outcome measures underrealistic SNRs. It also highlighted interactions between WMC and sentence context on feature efficacy.<br />


2010 ◽  
Vol 21 (08) ◽  
pp. 546-557 ◽  
Author(s):  
Kristi Oeding ◽  
Michael Valente ◽  
Jessica Kerckhoff

Background: Patients with unilateral sensorineural hearing loss (USNHL) experience great difficulty listening to speech in noisy environments. A directional microphone (DM) could potentially improve speech recognition in this difficult listening environment. It is well known that DMs in behind-the-ear (BTE) and custom hearing aids can provide a greater signal-to-noise ratio (SNR) in comparison to an omnidirectional microphone (OM) to improve speech recognition in noise for persons with hearing impairment. Studies examining the DM in bone anchored auditory osseointegrated implants (Baha), however, have been mixed, with little to no benefit reported for the DM compared to an OM. Purpose: The primary purpose of this study was to determine if there are statistically significant differences in the mean reception threshold for sentences (RTS in dB) in noise between the OM and DM in the Baha® Divino™. The RTS of these two microphone modes was measured utilizing two loudspeaker arrays (speech from 0° and noise from 180° or a diffuse eight-loudspeaker array) and with the better ear open or closed with an earmold impression and noise attenuating earmuff. Subjective benefit was assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) to compare unaided and aided (Divino OM and DM combined) problem scores. Research Design: A repeated measures design was utilized, with each subject counterbalanced to each of the eight treatment levels for three independent variables: (1) microphone (OM and DM), (2) loudspeaker array (180° and diffuse), and (3) better ear (open and closed). Study Sample: Sixteen subjects with USNHL currently utilizing the Baha were recruited from Washington University's Center for Advanced Medicine and the surrounding area. Data Collection and Analysis: Subjects were tested at the initial visit if they entered the study wearing the Divino or after at least four weeks of acclimatization to a loaner Divino. The RTS was determined utilizing Hearing in Noise Test (HINT) sentences in the R-Space™ system, and subjective benefit was determined utilizing the APHAB. A three-way repeated measures analysis of variance (ANOVA) and a paired samples t-test were utilized to analyze results of the HINT and APHAB, respectively. Results: Results revealed statistically significant differences within microphone (p < 0.001; directional advantage of 3.2 dB), loudspeaker array (p = 0.046; 180° advantage of 1.1 dB), and better ear conditions (p < 0.001; open ear advantage of 4.9 dB). Results from the APHAB revealed statistically and clinically significant benefit for the Divino relative to unaided on the subscales of Ease of Communication (EC) (p = 0.037), Background Noise (BN) (p < 0.001), and Reverberation (RV) (p = 0.005). Conclusions: The Divino's DM provides a statistically significant improvement in speech recognition in noise compared to the OM for subjects with USNHL. Therefore, it is recommended that audiologists consider selecting a Baha with a DM to provide improved speech recognition performance in noisy listening environments.


2013 ◽  
Vol 22 (1) ◽  
pp. 84-93 ◽  
Author(s):  
Francis Kuk ◽  
Petri Korhonen ◽  
Chi Lau ◽  
Denise Keenan ◽  
Magnus Norgaard

Purpose This study was designed to evaluate the effect of a pinna compensation (PC) algorithm on localization performance in the horizontal plane and speech intelligibility in noise. Method Nine and 18 experienced hearing aid users with bilaterally symmetrical sensorineural hearing loss participated in the localization study and the speech-in-noise study, respectively. Performance was evaluated unaided, aided with a behind-the-ear (BTE) hearing aid with an omnidirectional microphone (Omni), and aided with the same hearing aid with the PC algorithm (Omni+PC). Localization performance was measured using 12 loudspeakers spaced 30° apart on a horizontal plane. Speech-in-noise performance was measured with speech presented from 0° or 180°. A single-blinded, repeated measures design was used. Results Significant improvement in localization accuracy was found when comparing the Omni+PC condition to the Omni condition. Also, the Omni+PC condition improved the signal-to-noise ratio by 2.4 dB when compared to the Omni condition when speech was presented from the front in a diffuse noise background. Conclusion Use of the PC algorithm improved localization on the horizontal plane and speech-in-noise performance. These results support use of the PC algorithm in BTE hearing aid fittings.


2015 ◽  
Vol 26 (03) ◽  
pp. 275-288 ◽  
Author(s):  
Francis Kuk ◽  
Chi-chuen Lau ◽  
Petri Korhonen ◽  
Bryan Crose

Background: Although the benefits of hearing aids are generally recognized for soft- and conversational-level sounds, most studies have reported negative benefits (i.e., poorer aided than unaided performance) at high noise inputs. Advances in digital signal processing such as compression, noise reduction, and directional microphone could improve speech perception at high input levels. This could alter our view on the efficacy of hearing aids in loud, noisy situations. Purpose: The current study compared the aided versus the unaided speech intelligibility performance of hearing-impaired (HI) listeners at various input levels (from 50–100 dB SPL) and signal-to-noise ratios (SNRs; quiet, +6, +3, and –3 dB) in order to document the benefits of modern hearing aids. In addition, subjective preference between aided and unaided sounds (speech and music) at various input levels was also compared. Research Design: The experiment used a factorial repeated-measures design. Study Sample: A total of 10 HI adults with symmetrical moderate to severe hearing losses served as test participants. In addition, speech intelligibility scores of five normal-hearing (NH) listeners were also measured for comparison. Intervention: Speech perception was studied at 50 and 65 dB SPL input levels in quiet and also in noise at levels of 65, 85, and 100 dB SPL with SNRs of +6, +3, and –3 dB. This was done for all participants (HI and NH). In addition, the HI participants compared subjective preference between the aided and unaided presentations of speech and music stimuli at 50, 65, 85, and 100 dB SPL in quiet. Data Collection and Analysis: The data were analyzed with repeated-measures analysis of variance. Results: The results showed a decrease in aided benefits as input levels increased. However, even at the two highest input levels (i.e., 85 and 100 dB SPL), aided speech scores were still higher than the unaided speech scores. Furthermore, NH listeners and HI listeners in the aided condition showed stable speech-in-noise performance between 65 and 100 dB SPL input levels, except that the absolute performance of the NH listeners was higher than that of the HI listeners. Subjective preference for the unaided sounds versus the aided sounds increased as input level increased, with a crossover intensity at approximately 75 dB SPL for speech and 80 dB SPL for music. Conclusions: The results supported the hypothesis that the study hearing aid can provide aided speech-in-noise benefit at very high noise inputs in a controlled environment.


2015 ◽  
Vol 26 (01) ◽  
pp. 093-100 ◽  
Author(s):  
Jace Wolfe ◽  
Erin Schafer ◽  
Emily Mills ◽  
Andrew John ◽  
Mary Hudson ◽  
...  

Background: There is a paucity of published studies examining how children with hearing loss understand speech over the telephone. Previous studies on adults with hearing aids have suggested that adults with bilateral hearing aids experience significant difficulty recognizing speech on the telephone when listening with one ear, but the provision of telephone input to both ears substantially improved speech understanding. Purpose: The objectives of this study were to measure speech recognition in quiet and in noise for a group of older children with hearing loss over the telephone and to evaluate the effects of binaural hearing (e.g., DuoPhone) on speech recognition over the telephone. Research Design: A cross-sectional, repeated-measures design was used in this study. Study Sample: A total of 14 children, ages 6–14 yr, participated in the study. Participants were obtained using convenience sampling from a nonprofit clinic population. Intervention: Speech recognition in quiet and in noise with binaural versus monaural telephone input was compared in pediatric participants. Data Collection and Analysis: Monosyllabic word recognition was assessed in quiet and classroom noise set at 50 dBA in conditions with monaural and binaural (DuoPhone) telephone input. Results: The children’s speech recognition in quiet and in noise was significantly better with binaural telephone input relative to monaural telephone input. Conclusions: To obtain optimal performance on the telephone, the following considerations may apply: (1) use of amplification with binaural streaming capabilities (e.g., DuoPhone), (2) counseling of family and children on how to best use the telephone, (3) provision of telecoil with microphone attenuation for improved signal-to-noise ratio, and (4) use of probe tube measures to verify the appropriateness of the telephone programs.


2021 ◽  
Vol 25 ◽  
pp. 233121652199761
Author(s):  
Yuan Chen ◽  
Lena L. N. Wong ◽  
Volker Kuehnel ◽  
Jinyu Qian ◽  
Solveig Christina Voss ◽  
...  

The aim of this study was to evaluate the efficacy of dual compression for Mandarin-speaking hearing aid users. Dual compression combines fast and slow compressors operating simultaneously across all frequency channels. The study participants were 31 hearing aid users with symmetrical moderate-to-severe hearing loss, with a mean age of 67 years. A new pair of 20-channel behind-the-ear hearing aids (i.e., Phonak Bolero B90-P) was used during the testing. The results revealed a significant improvement in speech reception thresholds in noise when switching from fast-acting compression to dual compression. The sound quality ratings revealed that most listeners preferred dual compression to fast-acting compression for listening effort, listening comfort, speech clarity, and overall sound quality at +4 dB signal-to-noise ratio. These results are consistent with predictions based on the theoretical understanding of dual and fast-acting compression. However, whether these results can be generalized to other languages or other dual compression systems should be verified by future studies.


Sign in / Sign up

Export Citation Format

Share Document