scholarly journals Quantifying the Impact of Load-Following on Gas-fired Power Plants

2021 ◽  
Author(s):  
Yifan Wang
2014 ◽  
Vol 521 ◽  
pp. 530-535
Author(s):  
Meng Wang ◽  
Jian Ding ◽  
Tian Tang ◽  
Zhang Sui Lin ◽  
Zhen Da Hu ◽  
...  

The current situation of nuclear power plants at home and abroad is described, and the impact of large-scale nuclear power accessing to the grid is analyzed, specifically in the aspects of nuclear power modeling, simulation, load following, reliability, fault diagnosis, etc. Nuclear power accessing to the grid will bring a series of problems, the causes of each problem, the main solutions and future development directions are summarized.


Author(s):  
Ye Cheng ◽  
Wang Minglu ◽  
Qiu Zhongming ◽  
Wang Yong

Nuclear power plants are used extensively as base load sources of electricity. This is the most economical and technically simple mode of operation. In this mode, power changes are limited to frequency regulation for grid stability purposes and shutdowns for safety purposes. However for countries with high nuclear shares or desiring to significantly increase renewable energy sources, the question arises as to the ability of nuclear power plants to follow load on a regular basis, including daily variations of the power demand. This paper give a detailed analysis of the technical and economic aspects of load-following with nuclear power plants, and summaries the impact of load-following on the operational mode.


Processes ◽  
2018 ◽  
Vol 6 (11) ◽  
pp. 226 ◽  
Author(s):  
Parikshit Sarda ◽  
Elijah Hedrick ◽  
Katherine Reynolds ◽  
Debangsu Bhattacharyya ◽  
Stephen E. Zitney ◽  
...  

Traditional energy production plants are increasingly forced to cycle their load and operate under low-load conditions in response to growth in intermittent renewable generation. A plant-wide dynamic model of a supercritical pulverized coal (SCPC) power plant has been developed in the Aspen Plus Dynamics® (APD) software environment and the impact of advanced control strategies on the transient responses of the key variables to load-following operation and disturbances can be studied. Models of various key unit operations, such as the steam turbine, are developed in Aspen Custom Modeler® (ACM) and integrated in the APD environment. A coordinated control system (CCS) is developed above the regulatory control layer. Three control configurations are evaluated for the control of the main steam; the reheat steam temperature is also controlled. For studying servo control performance of the CCS, the load is decreased from 100% to 40% at a ramp rate of 3% load per min. The impact of a disturbance due to a change in the coal feed composition is also studied. The CCS is found to yield satisfactory performance for both servo control and disturbance rejection.


2021 ◽  
Vol 13 (13) ◽  
pp. 7279
Author(s):  
Zbigniew Skibko ◽  
Magdalena Tymińska ◽  
Wacław Romaniuk ◽  
Andrzej Borusiewicz

Wind power plants are an increasingly common source of electricity located in rural areas. As a result of the high variability of wind power, and thus the generated power, these sources should be classified as unstable sources. In this paper, the authors attempted to determine the impact of wind turbine operation on the parameters of electricity supplied to farms located near the source. As a result of the conducted field tests, variability courses of the basic parameters describing the supply voltage were obtained. The influence of power plant variability on the values of voltage, frequency, and voltage distortion factor was determined. To estimate the capacity of the transmission lines, the reactive power produced in the power plant and its effect on the value of the power factor were determined. The conducted research and analysis showed that the wind power plant significantly influences voltage fluctuations in its immediate vicinity (the maximum value registered was close to 2%, while the value required by law was 2.5%). Although all the recorded values are within limits specified by the current regulations (e.g., the THD value is four times lower than the required value), wind turbines may cause incorrect operation of loads connected nearby. This applies mainly to cases where consumers sensitive to voltage fluctuations are installed in the direct vicinity of the power plant.


Sign in / Sign up

Export Citation Format

Share Document