scholarly journals The Passivhaus Standard in the Spanish Mediterranean: Evaluation of a House’s Thermal Behaviour of Enclosures and Airtightness

2019 ◽  
Vol 11 (13) ◽  
pp. 3732 ◽  
Author(s):  
Víctor Echarri-Iribarren ◽  
Cristina Sotos-Solano ◽  
Almudena Espinosa-Fernández ◽  
Raúl Prado-Govea

Few houses have been built in the Spanish Mediterranean in accordance with the Passivhaus (PH) standard. This standard is adapted to the continental climates of Central Europe and thorough studies are necessary to apply this standard in Spain, especially in the summer. High relative air humidity levels in coastal areas and solar radiation levels of west-facing façades require adapted architectural designs, as well as greater control of air renewal and dehumidification. A priori, energy consumptions undergo big variations. In this study, the construction of a single-family house in the Spanish Levante was analysed. All enclosure layers were monitored using sensors of surface temperature, solar radiation, indoor and outdoor air temperature, relative humidity, and air speed. The thermal behaviour of the façade enclosure and air infiltration through the enclosure were examined using the blower door test and impacts on annual energy demand were quantified. Using simulation tools, improvements are proposed, and the results are compared with examples of PH housing in other geographical areas. The annual energy demand of PH housing was 69.19% below the usual value for buildings in the Mediterranean region. Very thick thermal insulation and low values of airtightness could be applied to the envelope, which would work very well in the winter. These technique solutions could provide optimal comfort conditions with a well-designed air conditioning system in summer and low energy consumption.

2021 ◽  
Vol 11 (2) ◽  
pp. 500
Author(s):  
Fabrizio Pilo ◽  
Giuditta Pisano ◽  
Simona Ruggeri ◽  
Matteo Troncia

The energy transition for decarbonization requires consumers’ and producers’ active participation to give the power system the necessary flexibility to manage intermittency and non-programmability of renewable energy sources. The accurate knowledge of the energy demand of every single customer is crucial for accurately assessing their potential as flexibility providers. This topic gained terrific input from the widespread deployment of smart meters and the continuous development of data analytics and artificial intelligence. The paper proposes a new technique based on advanced data analytics to analyze the data registered by smart meters to associate to each customer a typical load profile (LP). Different LPs are assigned to low voltage (LV) customers belonging to nominal homogeneous category for overcoming the inaccuracy due to non-existent coincident peaks, arising by the common use of a unique LP per category. The proposed methodology, starting from two large databases, constituted by tens of thousands of customers of different categories, clusters their consumption profiles to define new representative LPs, without a priori preferring a specific clustering technique but using that one that provides better results. The paper also proposes a method for associating the proper LP to new or not monitored customers, considering only few features easily available for the distribution systems operator (DSO).


Energy Policy ◽  
2021 ◽  
Vol 153 ◽  
pp. 112276
Author(s):  
Matxalen Etxebarria-Mallea ◽  
Xabat Oregi ◽  
Olatz Grijalba ◽  
Rufino Hernández-Minguillón

Author(s):  
Gustavo H. da Silva ◽  
Santos H. B. Dias ◽  
Lucas B. Ferreira ◽  
Jannaylton É. O. Santos ◽  
Fernando F. da Cunha

ABSTRACT FAO Penman-Monteith (FO-PM) is considered the standard method for the estimation of reference evapotranspiration (ET0) but requires various meteorological data, which are often not available. The objective of this work was to evaluate the performance of the FAO-PM method with limited meteorological data and other methods as alternatives to estimate ET0 in Jaíba-MG. The study used daily meteorological data from 2007 to 2016 of the National Institute of Meteorology’s station. Daily ET0 values were randomized, and 70% of these were used to determine the calibration parameters of the ET0 for the equations of each method under study. The remaining data were used to test the calibration against the standard method. Performance evaluation was based on Willmott’s index of agreement, confidence coefficient and root-mean-square error. When one meteorological variable was missing, either solar radiation, relative air humidity or wind speed, or in the simultaneous absence of wind speed and relative air humidity, the FAO-PM method showed the best performances and, therefore, was recommended for Jaíba. The FAO-PM method with two missing variables, one of them being solar radiation, showed intermediate performance. Methods that used only air temperature data are not recommended for the region.


Author(s):  
Raffaele Capuano ◽  
Thomas Fend ◽  
Bernhard Hoffschmidt ◽  
Robert Pitz-Paal

Due to the continuous global increase in energy demand, Concentrated Solar Power (CSP) represents an excellent alternative, or add-on to existing systems for the production of energy on a large scale. In some of these systems, the Solar Power Tower plants (SPT), the conversion of solar radiation into heat occurs in certain components defined as solar receivers, placed in correspondence of the focus of the reflected sunlight. In a particular type of solar receivers, defined as volumetric, the use of porous materials is foreseen. These receivers are characterized by a porous structure called absorber. The latter, hit by the reflected solar radiation, transfers the heat to the evolving fluid, generally air subject to natural convection. The proper design of these elements is essential in order to achieve high efficiencies, making such structures extremely beneficial for the overall performances of the energy production process. In the following study, a parametric analysis and an optimized characterization of the structure have been performed with the use of self-developed numerical models. The knowledge and results gained through this study have been used to define an optimization path in order to improve the absorber microstructure, starting from the current in-house state-of-the-art technology until obtaining a new advanced geometry.


Author(s):  
Marcin Koniorczyk ◽  
Witold Grymin ◽  
Marcin Zygmunt ◽  
Dalia Bednarska ◽  
Alicja Wieczorek ◽  
...  

AbstractIn the analyses of the uncertainty propagation of buildings’ energy-demand, the Monte Carlo method is commonly used. In this study we present two alternative approaches: the stochastic perturbation method and the transformed random variable method. The energy-demand analysis is performed for the representative single-family house in Poland. The investigation is focused on two independent variables, considered as uncertain, the expanded polystyrene thermal conductivity and external temperature; however the generalization on any countable number of parameters is possible. Afterwards, the propagation of the uncertainty in the calculations of the energy consumption has been investigated using two aforementioned approaches. The stochastic perturbation method is used to determine the expected value and central moments of the energy consumption, while the transformed random variable method allows to obtain the explicit form of energy consumption probability density function and further characteristic parameters like quantiles of energy consumption. The calculated data evinces a high accordance with the results obtained by means of the Monte Carlo method. The most important conclusions are related to the computational cost reduction, simplicity of the application and the appropriateness of the proposed approaches for the buildings’ energy-demand calculations.


Buildings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 348
Author(s):  
Sahar Magri Elouadjeri ◽  
Aicha Boussoualim ◽  
Hassan Ait Haddou

The present study investigates the effect of fixed external shading devices’ geometry on thermal comfort, daylighting and energy demand for cooling and heating in the hot and dry climate of the city of Ghardaïa (Algeria). A parametric analysis was performed by using three software: RADIANCE 2.0 and DAYSIM 3.1 for daylighting simulation and TRNSYS.17 for thermal dynamic simulation. Three shading device parameters were assessed: the spacing between slats, the tilted angle and the slats installation. The vertical shading angle “VSA” is fixed; it is equal to the optimum shading angle measured for Ghardaïa. The simulation results indicate that fixed external shading devices have a significant impact on decreasing the energy demand for cooling; however, they are unable to reduce the total energy demand since they significantly increase heating loads. It was found that fixed external shading devices remove all risks associated with glare in summer by decreasing illuminance close to the window; however, they do not improve daylighting performance in winter because of glare. We note that even if the vertical shading angle “VSA” was the same for all cases, these did not present the same thermal and luminous behavior. This is mainly due to the amount and the way that the solar radiation penetrates space.


2021 ◽  
Vol 14 (1) ◽  
pp. 65
Author(s):  
Muhammad Usman ◽  
Georg Frey

The comprehensive approach for a building envelope design involves building performance simulations, which are time-consuming and require knowledge of complicated processes. In addition, climate variation makes the selection of these parameters more complex. The paper aims to establish guidelines for determining a single-family household’s unique optimal passive design in various climate zones worldwide. For this purpose, a bi-objective optimization is performed for twenty-four locations in twenty climates by coupling TRNSYS and a non-dominated sorting genetic algorithm (NSGA-III) using the Python program. The optimization process generates Pareto fronts of thermal load and investment cost to identify the optimum design options for the insulation level of the envelope, window aperture for passive cooling, window-to-wall ratio (WWR), shading fraction, radiation-based shading control, and building orientation. The goal is to find a feasible trade-off between thermal energy demand and the cost of thermal insulation. This is achieved using multi-criteria decision making (MCDM) through criteria importance using intercriteria correlation (CRITIC) and the technique for order preference by similarity to ideal solution (TOPSIS). The results demonstrate that an optimal envelope design remarkably improves the thermal load compared to the base case of previous envelope design practices. However, the weather conditions strongly influence the design parameters. The research findings set a benchmark for energy-efficient household envelopes in the investigated climates. The optimal solution sets also provide a criterion for selecting the ranges of envelope design parameters according to the space heating and cooling demands of the climate zone.


Author(s):  
Rabbani Rasha ◽  
M. Tariq Iqbal

This paper represents an energy consumption and heat loss analysis of a heat recovery ventilator unit in a single-family detached house in St. John’s, NL, Canada. An energy-efficient house is a growing attraction to control the air infiltration, provide a comfortable environment with reduced yearly electricity cost. A mechanical induced ventilation system is inevitable to increase energy efficiency and to reduce greenhouse gas emissions of the house in order to supply fresh air. A heat recovery ventilator (HRV) is an air to air heat exchangers that recovers heat from inside of the house and delivers this preheated and fresh air to the space for maintaining the occupant’s comfort. In this paper, yearly energy consumption with the heat loss of a typical heat recovery ventilator unit is presented. MATLAB, BE opt, and Microsoft Excel are used to do all necessary simulation with calculation using one-year logged data. Methodology, results with graphs and detailed analysis of this research are included in this paper. This research indicates that the cost of running a HRV for a year in a house in St. John’s could be as high as $484 per year with an unknown air quality improvement.


2021 ◽  
Author(s):  
Ashish Kumar Chowdhary ◽  
Debabrata Sikdar

Abstract To meet the global energy demand, rapid growth in fossil fuel consumption has significantly contributed to global warming. Judicious utilization of renewable energy resources could help to combat this global challenge. Here, we present a comparative study on the designs of static and electro-tunable ‘smart’ windows that could help to reduce the energy need of typical airconditioning systems deployed in buildings and motor vehicles. Our design comprises insulator–metal–insulator multi-layered thin-films deposited over a silica glass substrate to filter visible and infrared solar radiation selectively. For static windows, we optimize our design to operate in diverse climatic conditions by choosing different combinations and thicknesses of metal and insulator layers. Whereas for electro-tunable windows, we use an electro–optic polymer as the insulator layers to dynamically control portions of transmitted solar radiation over a voltage range of −12 V to +12 V. Through size-dependence analysis, we could safely assume that the performance of smart windows is less likely to degrade during experimental realization. Our designs are lithography-free, large-area compatible, polarization-independent, angle-insensitive, and robust to fabrication imperfections. The analytical results show a near-perfect match with the simulation findings. The theoretically calculated figure of merit indicates that our proposed smart windows can outperform industry-standard commercial windows.


2021 ◽  
Author(s):  
Bingbing Duan ◽  
Urs Hugentobler ◽  
Inga Selmke ◽  
Stefan Marz

<p>A physical a priori box-wing solar radiation pressure (SRP) model is widely used by most analysis centers for Galileo and QZSS (Quasi-Zenith Satellite System) satellites, complemented by an ECOM or ECOM2 (Empirical CODE Orbit Model) model. For the other constellations, for instance GPS and GLONASS satellites, optical properties of satellite surfaces are not publicly available, especially for GPS Block IIF and GLONASS satellites. By fixing satellite surface areas and total mass to the values from some unpublished documents, we estimate satellite surface optical properties based on true GNSS measurements covering long time periods (typically this should be longer than a full beta angle time range to reduce correlations between parameters). Meanwhile, various physical effects are considered, such as yaw bias, radiator emission and thermal radiation of solar panels. We find that yaw bias of GPS Block IIA and IIR satellites does not dominate the Y-bias, it is likely that heat generated in the satellite is radiated from louvers or heat pipes on the Y side of the satellite. It is also noted that the ECOM Y0 estimates of both GPS and GLONASS satellites show clear anomaly during eclipse seasons. This indicates that the radiator emission is present when the satellite crosses shadows. Since satellite attitude during eclipse seasons could be different from the nominal yaw, potential radiator effect in the –X surface could be wrongly absorbed by the ECOM Y0 as well. By considering all the estimated parameters in an a priori model we observe clear improvement in satellite orbits, especially for GLONASS satellites. China’s Beidou-3 satellites are now providing PNT (positioning, navigation and timing) service globally. Satellite attitude, dimensions and total mass are publicly available. Also, the absorption optical properties of each satellite surface are given. With all this information, we estimate the other optical properties of Beidou satellites considering similar yaw bias, radiator and thermal radiation effects as those in GPS and GLONASS satellites.</p>


Sign in / Sign up

Export Citation Format

Share Document