scholarly journals Computational Diagnostic Techniques for Electrocardiogram Signal Analysis

Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6318
Author(s):  
Liping Xie ◽  
Zilong Li ◽  
Yihan Zhou ◽  
Yiliu He ◽  
Jiaxin Zhu

Cardiovascular diseases (CVDs), including asymptomatic myocardial ischemia, angina, myocardial infarction, and ischemic heart failure, are the leading cause of death globally. Early detection and treatment of CVDs significantly contribute to the prevention or delay of cardiovascular death. Electrocardiogram (ECG) records the electrical impulses generated by heart muscles, which reflect regular or irregular beating activity. Computer-aided techniques provide fast and accurate tools to identify CVDs using a patient’s ECG signal, which have achieved great success in recent years. Latest computational diagnostic techniques based on ECG signals for estimating CVDs conditions are summarized here. The procedure of ECG signals analysis is discussed in several subsections, including data preprocessing, feature engineering, classification, and application. In particular, the End-to-End models integrate feature extraction and classification into learning algorithms, which not only greatly simplifies the process of data analysis, but also shows excellent accuracy and robustness. Portable devices enable users to monitor their cardiovascular status at any time, bringing new scenarios as well as challenges to the application of ECG algorithms. Computational diagnostic techniques for ECG signal analysis show great potential for helping health care professionals, and their application in daily life benefits both patients and sub-healthy people.

2019 ◽  
Vol 10 (3) ◽  
pp. 1621-1625
Author(s):  
Sharanya S ◽  
Sridhar PA ◽  
Suresh MP ◽  
Poorana Mary Monisha W ◽  
Tharadevi R

Analysis of Electrocardiogram (ECG) signal can lead to better detection of cardiac arrhythmia. The important steps involved in the ECG signal analysis include acquisition of data, pre-processing of signal to remove artefacts, feature extraction of attributes and finally identifying abnormalities. This work proposes an efficient implementation of the R-R interval-based ECG classification technique for detecting abnormalities in heart functioning. ECG signals from an online database (PhysioNet.org) was analysed after noise removal for R-R interval, as R peak has the maximum prominent amplitude in ECG wave. Deviation in the R-R interval values obtained from unhealthy was observed and compared with healthy subjects. This observation of cardiac activity can be visualised in our developed Graphical User Interface (GUI). The GUI platform requires only the input of the ECG signal that is to be analysed for abnormalities, which can provide the clinician with the result of cardiac abnormality classification and can help in diagnosis.  


Heart and Eye are two vital organs in the human system. By knowing the Electrocardiogram (ECG) and Electro-oculogram (EOG), one will be able to tell the stability of the heart and eye respectively. In this project, we have developed a circuit to pick the ECG and EOG signal using two wet electrodes. Here no reference electrode is used. EOG and ECG signals have been acquired from ten healthy subjects. The ECG signal is obtained from two positions, namely wrist and arm position respectively. The picked-up biomedical signal is recorded and heart rate information is extracted from ECG signal using the biomedical workbench. The result found to be promising and acquired stable EOG and ECG signal from the subjects. The total gain required for the arm position is higher than the wrist position for the ECG signal. The total gain necessary for the EOG signal is higher than the ECG signal since the ECG signal is in the range of millivolts whereas EOG signal in the range of microvolts. This two-electrode system is stable, cost-effective and portable while still maintaining high common-mode rejection ratio (CMRR).


Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 2835 ◽  
Author(s):  
Zhongjie Hou ◽  
Jinxi Xiang ◽  
Yonggui Dong ◽  
Xiaohui Xue ◽  
Hao Xiong ◽  
...  

A prototype of an electrocardiogram (ECG) signal acquisition system with multiple unipolar capacitively coupled electrodes is designed and experimentally tested. Capacitively coupled electrodes made of a standard printed circuit board (PCB) are used as the sensing electrodes. Different from the conventional measurement schematics, where one single lead ECG signal is acquired from a pair of sensing electrodes, the sensing electrodes in our approaches operate in a unipolar mode, i.e., the biopotential signals picked up by each sensing electrodes are amplified and sampled separately. Four unipolar electrodes are mounted on the backrest of a regular chair and therefore four channel of signals containing ECG information are sampled and processed. It is found that the qualities of ECG signal contained in the four channel are different from each other. In order to pick up the ECG signal, an index for quality evaluation, as well as for aggregation of multiple signals, is proposed based on phase space reconstruction. Experimental tests are carried out while subjects sitting on the chair and clothed. The results indicate that the ECG signals can be reliably obtained in such a unipolar way.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Jia Li ◽  
Yujuan Si ◽  
Tao Xu ◽  
Saibiao Jiang

Although convolutional neural networks (CNNs) can be used to classify electrocardiogram (ECG) beats in the diagnosis of cardiovascular disease, ECG signals are typically processed as one-dimensional signals while CNNs are better suited to multidimensional pattern or image recognition applications. In this study, the morphology and rhythm of heartbeats are fused into a two-dimensional information vector for subsequent processing by CNNs that include adaptive learning rate and biased dropout methods. The results demonstrate that the proposed CNN model is effective for detecting irregular heartbeats or arrhythmias via automatic feature extraction. When the proposed model was tested on the MIT-BIH arrhythmia database, the model achieved higher performance than other state-of-the-art methods for five and eight heartbeat categories (the average accuracy was 99.1% and 97%). In particular, the proposed system had better performance in terms of the sensitivity and positive predictive rate for V beats by more than 4.3% and 5.4%, respectively, and also for S beats by more than 22.6% and 25.9%, respectively, when compared to existing algorithms. It is anticipated that the proposed method will be suitable for implementation on portable devices for the e-home health monitoring of cardiovascular disease.


2019 ◽  
Vol 29 (02) ◽  
pp. 2050024
Author(s):  
Mahesh B. Dembrani ◽  
K. B. Khanchandani ◽  
Anita Zurani

The automatic recognition of QRS complexes in an Electrocardiography (ECG) signal is a critical step in any programmed ECG signal investigation, particularly when the ECG signal taken from the pregnant women additionally contains the signal of the fetus and some motion artifact signals. Separation of ECG signals of mother and fetus and investigation of the cardiac disorders of the mother are demanding tasks, since only one single device is utilized and it gets a blend of different heart beats. In order to resolve such problems we propose a design of new reconfigurable Subtractive Savitzky–Golay (SSG) filter with Digital Processor Back-end (DBE) in this paper. The separation of signals is done using Independent Component Analysis (ICA) algorithm and then the motion artifacts are removed from the extracted mother’s signal. The combinational use of SSG filter and DBE enhances the signal quality and helps in detecting the QRS complex from the ECG signal particularly the R peak accurately. The experimental results of ECG signal analysis show the importance of our proposed method.


Author(s):  
CHUANG-CHIEN CHIU ◽  
CHOU-MIN CHUANG ◽  
CHIH-YU HSU

The main purpose of this study is to present a novel personal authentication approach with the electrocardiogram (ECG) signal. The electrocardiogram is a recording of the electrical activity of the heart and the recorded signals can be used for individual verification because ECG signals of one person are never the same as those of others. The discrete wavelet transform was applied for extracting features that are the wavelet coefficients derived from digitized signals sampled from one-lead ECG signal. By the proposed approach applied on 35 normal subjects and 10 arrhythmia patients, the verification rate was 100% for normal subjects and 81% for arrhythmia patients. Furthermore, the performance of the ECG verification system was evaluated by the false acceptance rate (FAR) and false rejection rate (FRR). The FAR was 0.83% and FRR was 0.86% for a database containing only 35 normal subjects. When 10 arrhythmia patients were added into the database, FAR was 12.50% and FRR was 5.11%. The experimental results demonstrated that the proposed approach worked well for normal subjects. For this reason, it can be concluded that ECG used as a biometric measure for personal identity verification is feasible.


Author(s):  
Mohand Lokman Ahmad Al-dabag ◽  
Haider Th. Salim ALRikabi ◽  
Raid Rafi Omar Al-Nima

One of the common types of arrhythmia is Atrial Fibrillation (AF), it may cause death to patients. Correct diagnosing of heart problem through examining the Electrocardiogram (ECG) signal will lead to prescribe the right treatment for a patient. This study proposes a system that distinguishes between the normal and AF ECG signals. First, this work provides a novel algorithm for segmenting the ECG signal for extracting a single heartbeat. The algorithm utilizes low computational cost techniques to segment the ECG signal. Then, useful pre-processing and feature extraction methods are suggested. Two classifiers, Support Vector Machine (SVM) and Multilayer Perceptron (MLP), are separately used to evaluate the two proposed algorithms. The performance of the last proposed method with the two classifiers (SVM and MLP) show an improvement of about (19% and 17%, respectively) after using the proposed segmentation method so it became 96.2% and 97.5%, respectively.


Author(s):  
WANSONG XU ◽  
TIANWU CHEN ◽  
FANYU DU

Objective: The detection of QRS complexes is an important part of computer-aided analysis of electrocardiogram (ECG). However, most of the existing detection algorithms are mainly for single-lead ECG signals, which requires high quality of signal. If the signal quality decreases suddenly due to some interference, then the current algorithm is easy to cause misjudgment or missed detection. To improve the detection ability of QRS complexes under sudden interference, we study the QRS complexes information on multiple leads in-depth, and propose a two-lead joint detection algorithm of QRS complexes. Methods: Firstly, the suspected QRS complexes are screened on the main lead. For the suspected QRS complexes with low confidence and the complexes that may be missed, further accurate detection and joint judgment shall be carried out at the corresponding position of the auxiliary lead. At the same time, the adaptive threshold adjustment algorithm and backtracking mechanism are used to modify the detection results. Results: The proposed detection algorithm is validated using 48 ECG records of the MIT-BIH arrhythmia database, and achieves average detection accuracy of 99.71%, sensitivity of 99.88% and positive predictivity of 99.81%. Conclusion: The proposed algorithm has high accuracy, which can effectively deal with the sudden interference of ECG signal. Meanwhile, the algorithm requires small amount of computation, and can be embedded into hardware for real-time detection.


2004 ◽  
Vol 12 (3) ◽  
pp. 152-158 ◽  
Author(s):  
Aleksandar Boskovic ◽  
Miroslav Despotovic ◽  
Dragana Bajic

Electrocardiogram (ECG) signal compression suffers of lack of standards for analogue-digital conversion. Results of this study have shown that 8 bits/sample, although frequently in use, does not satisfy quality criteria for medical doctors. This paper also presents predictive technique for lossless ECG compression using linear time-invariant models. Tests on clinically measured ECG signals confirm a very good performance in terms of compression ratio.


Author(s):  
Renuka Vijay Kapse

Health monitoring and technologies related to health monitoring is an appealing area of research. The electrocardiogram (ECG) has constantly being mainstream estimation plan to evaluate and analyse cardiovascular diseases. Heart health is important for everyone. Heart needs to be monitored regularly and early warning can prevent the permanent heart damage. Also heart diseases are the leading cause of death worldwide. Hence the work presents a design of a mini wearable ECG system and it’s interfacing with the Android application. This framework is created to show and analyze the ECG signal got from the ECG wearable system. The ECG signals will be shipped off an android application via Bluetooth device. This system will automatically alert the user through SMS.


Sign in / Sign up

Export Citation Format

Share Document