scholarly journals Comparison between the Airgo™ Device and a Metabolic Cart during Rest and Exercise

Sensors ◽  
2020 ◽  
Vol 20 (14) ◽  
pp. 3943
Author(s):  
Andrea Antonelli ◽  
Dario Guilizzoni ◽  
Alessandra Angelucci ◽  
Giulio Melloni ◽  
Federico Mazza ◽  
...  

The aim of this study is to compare the accuracy of Airgo™, a non-invasive wearable device that records breath, with respect to a gold standard. In 21 healthy subjects (10 males, 11 females), four parameters were recorded for four min at rest and in different positions simultaneously by Airgo™ and SensorMedics 2900 metabolic cart. Then, a cardio-pulmonary exercise test was performed using the Erg 800S cycle ergometer in order to test Airgo™’s accuracy during physical effort. The results reveal that the relative error median percentage of respiratory rate was of 0% for all positions at rest and for different exercise intensities, with interquartile ranges between 3.5 (standing position) and 22.4 (low-intensity exercise) breaths per minute. During exercise, normalized amplitude and ventilation relative error medians highlighted the presence of an error proportional to the volume to be estimated. For increasing intensity levels of exercise, Airgo™’s estimate tended to underestimate the values of the gold standard instrument. In conclusion, the Airgo™ device provides good accuracy and precision in the estimate of respiratory rate (especially at rest), an acceptable estimate of tidal volume and minute ventilation at rest and an underestimation for increasing volumes.

2016 ◽  
Vol 63 (1) ◽  
pp. 25-30
Author(s):  
Caroline McCarthy ◽  
Paul Brady ◽  
Ken D. O'Halloran ◽  
Christine McCreary

Hyperventilation can be a manifestation of anxiety that involves abnormally fast breathing (tachypnea) and an elevated minute ventilation that exceeds metabolic demand. This report describes a case of hyperventilation-induced hypocapnia resulting in tetany in a 16-year-old girl undergoing orthodontic extractions under intravenous conscious sedation. Pulse oximetry is the gold standard respiratory-related index in conscious sedation. Although the parameter has great utility in determining oxygen desaturation, it provides no additional information on respiratory function, including, for example, respiratory rate. In this case, we found capnography to be a very useful aid to monitor respiration in this patient and also to treat the hypocapnia.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2789
Author(s):  
Víctor Rodríguez-Rielves ◽  
José Ramón Lillo-Beviá ◽  
Ángel Buendía-Romero ◽  
Alejandro Martínez-Cava ◽  
Alejandro Hernández-Belmonte ◽  
...  

This study aimed to examine the validity and reliability of the recently developed Assioma Favero pedals under laboratory cycling conditions. In total, 12 well-trained male cyclists and triathletes (VO2max = 65.7 ± 8.7 mL·kg−1·min−1) completed five cycling tests including graded exercises tests (GXT) at different cadences (70–100 revolutions per minute, rpm), workloads (100–650 Watts, W), pedaling positions (seated and standing), vibration stress (20–40 Hz), and an 8-s maximal sprint. Tests were completed using a calibrated direct drive indoor trainer for the standing, seated, and vibration GXTs, and a friction belt cycle ergometer for the high-workload step protocol. Power output (PO) and cadence were collected from three different brand, new pedal units against the gold-standard SRM crankset. The three units of the Assioma Favero exhibited very high within-test reliability and an extremely high agreement between 100 and 250 W, compared to the gold standard (Standard Error of Measurement, SEM from 2.3–6.4 W). Greater PO produced a significant underestimating trend (p < 0.05, Effect size, ES ≥ 0.22), with pedals showing systematically lower PO than SRM (1–3%) but producing low bias for all GXT tests and conditions (1.5–7.4 W). Furthermore, vibrations ≥ 30 Hz significantly increased the differences up to 4% (p < 0.05, ES ≥ 0.24), whereas peak and mean PO differed importantly between devices during the sprints (p < 0.03, ES ≥ 0.39). These results demonstrate that the Assioma Favero power meter pedals provide trustworthy PO readings from 100 to 650 W, in either seated or standing positions, with vibrations between 20 and 40 Hz at cadences of 70, 85, and 100 rpm, or even at a free chosen cadence.


Biology ◽  
2022 ◽  
Vol 11 (1) ◽  
pp. 144
Author(s):  
Hun-Young Park ◽  
Jeong-Weon Kim ◽  
Sang-Seok Nam

We compared the effects of metabolic, cardiac, and hemorheological responses to submaximal exercise under light hypoxia (LH) and moderate hypoxia (MH) versus normoxia (N). Ten healthy men (aged 21.3 ± 1.0 years) completed 30 min submaximal exercise corresponding to 60% maximal oxygen uptake at normoxia on a cycle ergometer under normoxia (760 mmHg), light hypoxia (596 mmHg, simulated 2000 m altitude), and moderate hypoxia (526 mmHg, simulated 3000 m altitude) after a 30 min exposure in the respective environments on different days, in a random order. Metabolic parameters (oxygen saturation (SPO2), minute ventilation, oxygen uptake, carbon dioxide excretion, respiratory exchange ratio, and blood lactate), cardiac function (heart rate (HR), stroke volume, cardiac output, and ejection fraction), and hemorheological properties (erythrocyte deformability and aggregation) were measured at rest and 5, 10, 15, and 30 min after exercise. SPO2 significantly reduced as hypoxia became more severe (MH > LH > N), and blood lactate was significantly higher in the MH than in the LH and N groups. HR significantly increased in the MH and LH groups compared to the N group. There was no significant difference in hemorheological properties, including erythrocyte deformability and aggregation. Thus, submaximal exercise under light/moderate hypoxia induced greater metabolic and cardiac responses but did not affect hemorheological properties.


2018 ◽  
Vol 51 (5) ◽  
pp. 1702251 ◽  
Author(s):  
Paolo Biselli ◽  
Kathrin Fricke ◽  
Ludger Grote ◽  
Andrew T. Braun ◽  
Jason Kirkness ◽  
...  

Nasal high flow (NHF) reduces minute ventilation and ventilatory loads during sleep but the mechanisms are not clear. We hypothesised NHF reduces ventilation in proportion to physiological but not anatomical dead space.11 subjects (five controls and six chronic obstructive pulmonary disease (COPD) patients) underwent polysomnography with transcutaneous carbon dioxide (CO2) monitoring under a metabolic hood. During stable non-rapid eye movement stage 2 sleep, subjects received NHF (20 L·min−1) intermittently for periods of 5–10 min. We measured CO2 production and calculated dead space ventilation.Controls and COPD patients responded similarly to NHF. NHF reduced minute ventilation (from 5.6±0.4 to 4.8±0.4 L·min−1; p<0.05) and tidal volume (from 0.34±0.03 to 0.3±0.03 L; p<0.05) without a change in energy expenditure, transcutaneous CO2 or alveolar ventilation. There was a significant decrease in dead space ventilation (from 2.5±0.4 to 1.6±0.4 L·min−1; p<0.05), but not in respiratory rate. The reduction in dead space ventilation correlated with baseline physiological dead space fraction (r2=0.36; p<0.05), but not with respiratory rate or anatomical dead space volume.During sleep, NHF decreases minute ventilation due to an overall reduction in dead space ventilation in proportion to the extent of baseline physiological dead space fraction.


2006 ◽  
Vol 100 (3) ◽  
pp. 786-791 ◽  
Author(s):  
Joseph M. Dybas ◽  
Catharine J. Andresen ◽  
Edward S. Schelegle ◽  
Ryan W. McCue ◽  
Natasha N. Callender ◽  
...  

Deep-breath frequency has been shown to increase in spontaneously obstructed asthmatic subjects. Furthermore, deep breaths are known to be regulated by lung rapidly adapting receptors, yet the mechanism by which these receptors are stimulated is unclear. This study tested the hypothesis that deep-breath frequency increases during experimentally induced bronchoconstriction, and the magnitude of the increased deep-breath frequency is dependent on the method by which bronchoconstriction is induced. Nine cynomolgus monkeys ( Macaca fascicularis) were challenged with methacholine (MCh), Ascaris suum (AS), histamine, or an external mechanical resistance. Baseline (BL) and challenge deep-breath frequency were calculated from the number of deep breaths per trial period. Airway resistance (Raw) and tissue compliance (Cti), as well as tidal volume, respiratory rate, and minute ventilation, were analyzed for BL and challenged conditions. Transfer impedance measurements were fit with the DuBois model to determine the respiratory parameters (Raw and Cti). The flow at the airway opening was measured and analyzed on a breath-by-breath basis to obtain the ventilatory parameters (tidal volume, respiratory rate, and minute ventilation). Deep-breath frequency resulting from AS and histamine challenges [0.370 (SD 0.186) and 0.467 breaths/min (SD 0.216), respectively] was significantly increased compared with BL, MCh, or external resistance challenges [0.61 (SD 0.046), 0.156 (SD 0.173), and 0.117 breaths/min (SD 0.082), respectively]. MCh and external resistance challenges resulted in insignificant changes in deep-breath frequency compared with BL. All four modalities produced similar levels of bronchoconstriction, as assessed through changes in Raw and Cti, and had similar effects on the ventilatory parameters except that non-deep-breath tidal volume was decreased in AS and histamine. We propose that increased deep-breath frequency during AS and histamine challenge is the result of increased vascular permeability, which acts to increase rapidly adapting receptor activity.


1988 ◽  
Vol 64 (2) ◽  
pp. 753-758 ◽  
Author(s):  
J. K. Kalis ◽  
B. J. Freund ◽  
M. J. Joyner ◽  
S. M. Jilka ◽  
J. Nittolo ◽  
...  

The effect of beta-adrenergic blockade on the drift in O2 consumption (VO2 drift) typically observed during prolonged constant-rate exercise was studied in 14 healthy males in moderate heat at 40% of maximal O2 consumption (VO2max). After an initial maximum cycle ergometer test to determine the subjects' control VO2max, subjects were administered each of three medications: placebo, atenolol (100 mg once daily), and propranolol (80 mg twice daily), in a randomized double-blind fashion. Each medication period was 5 days in length and was followed by a 4-day washout period. On the 3rd day of each medication period, subjects performed a maximal cycle ergometer test. On the final day of each medication period, subjects exercised at 40% of their control VO2max for 90 min on a cycle ergometer in a warm (31.7 +/- 0.3 degrees C) moderately humid (44.7 +/- 4.7%) environment. beta-Blockade caused significant (P less than 0.05) reductions in VO2max, maximal minute ventilation (VEmax), maximal heart rate (HRmax), and maximal exercise time. Significantly greater decreases in VO2max, VEmax, and HRmax were associated with the propranolol compared with the atenolol treatment. During the 90-min submaximal rides, beta-blockade significantly reduced heart rate. Substantially lower values for O2 consumption (VO2) and minute ventilation (VE) were observed with propranolol compared with atenolol or placebo. Furthermore, VO2 drift and HR drift were observed under atenolol and placebo conditions but not with propranolol. Respiratory exchange ratio decreased significantly over time during the placebo and atenolol trials but did not change during the propranolol trial.(ABSTRACT TRUNCATED AT 250 WORDS)


2020 ◽  
Vol 30 (6) ◽  
pp. 549-556 ◽  
Author(s):  
Adrian Lis ◽  
Wojciech Łopusiewicz ◽  
Massimo F. Piepoli ◽  
Beata Ponikowska ◽  
Bartłomiej Paleczny

Abstract Purpose The exercise pressor reflex (EPR) plays a fundamental role in physiological reactions to exercise in humans and in the pathophysiology of cardiovascular disorders. There is no “gold standard” method for EPR assessment; therefore, we propose a new protocol for testing interactions between the muscle mechanoreflex and metaboreflex (major components of EPR). Methods Thirty-four healthy subjects (mean age [± standard deviation] 24 ± 4 years, 22 men) were enrolled in the study. During the study, the hemodynamic and ventilatory parameters of these subjects were continuously monitored using our proposed assessment method. This assessment method consists of an initial 5-min rest period (baseline) followed by 5 min of passive cycling (PC) on an automated cycle ergometer (mechanoreceptor stimulation), after which tourniquet cuffs located bilaterally on the upper thighs are inflated for 3 min to evoke venous and arterial regional circulatory occlusion (CO) during PC (metaboreceptor stimulation). Deflation of the tourniquet cuffs is followed by a second 5 min of PC and finally by a 5-min recovery time. The control test comprises a 5-min rest period, followed by 3 min of CO only and a final 5-min recovery. Results Mean arterial pressure (MAP) and minute ventilation (MV) increased significantly during PC (MAP: from 90 ± 9.3 to 95 ± 9.7 mmHg; MV: from 11.5 ± 2.5 to 13.5 ± 2.9 L/min; both p < 0.05) and again when CO was applied (MAP: from 95 ± 9.7 to 101 ± 11.0 mmHg; MV: from 13.5 ± 2.9 to 14.8 ± 3.8 L/min; both p < 0.05). In the control test there was a slight increase in MAP during CO (from 92 ± 10.5 to 94 ± 10.0 mmHg; p < 0.05) and no changes in the ventilatory parameters. Conclusion Bilateral leg passive cycling with concomitant circulatory occlusion is a new, simple and effective method for testing interactions between the mechanoreflex and metaboreflex in humans.


1996 ◽  
Vol 81 (5) ◽  
pp. 1978-1986 ◽  
Author(s):  
C. Tantucci ◽  
P. Bottini ◽  
M. L. Dottorini ◽  
E. Puxeddu ◽  
G. Casucci ◽  
...  

Tantucci, C., P. Bottini, M. L. Dottorini, E. Puxeddu, G. Casucci, L. Scionti, and C. A. Sorbini. Ventilatory response to exercise in diabetic subjects with autonomic neuropathy. J. Appl. Physiol. 81(5): 1978–1986, 1996.—We have used diabetic autonomic neuropathy as a model of chronic pulmonary denervation to study the ventilatory response to incremental exercise in 20 diabetic subjects, 10 with (Dan+) and 10 without (Dan−) autonomic dysfunction, and in 10 normal control subjects. Although both Dan+ and Dan− subjects achieved lower O2 consumption and CO2 production (V˙co 2) than control subjects at peak of exercise, they attained similar values of either minute ventilation (V˙e) or adjusted ventilation (V˙e/maximal voluntary ventilation). The increment of respiratory rate with increasing adjusted ventilation was much higher in Dan+ than in Dan− and control subjects ( P < 0.05). The slope of the linearV˙e/V˙co 2relationship was 0.032 ± 0.002, 0.027 ± 0.001 ( P < 0.05), and 0.025 ± 0.001 ( P < 0.001) ml/min in Dan+, Dan−, and control subjects, respectively. Both neuromuscular and ventilatory outputs in relation to increasingV˙co 2 were progressively higher in Dan+ than in Dan− and control subjects. At peak of exercise, end-tidal [Formula: see text] was much lower in Dan+ (35.9 ± 1.6 Torr) than in Dan− (42.1 ± 1.7 Torr; P < 0.02) and control (42.1 ± 0.9 Torr; P < 0.005) subjects. We conclude that pulmonary autonomic denervation affects ventilatory response to stressful exercise by excessively increasing respiratory rate and alveolar ventilation. Reduced neural inhibitory modulation from sympathetic pulmonary afferents and/or increased chemosensitivity may be responsible for the higher inspiratory output.


Sign in / Sign up

Export Citation Format

Share Document