scholarly journals A Low-Cost, Disposable and Portable Inkjet-Printed Biochip for the Developing World

Sensors ◽  
2020 ◽  
Vol 20 (12) ◽  
pp. 3593
Author(s):  
Kushal Joshi ◽  
Vanessa Velasco ◽  
Rahim Esfandyarpour

Electrowetting on dielectric-based digital microfluidic platforms (EWOD-DMF) have a potential to impact point-of-care diagnostics. Conventionally, EWOD-DMF platforms are manufactured in cleanrooms by expert technicians using costly and time consuming micro-nanofabrication processes such as optical lithography, depositions and etching. However, such high-end microfabrication facilities are extremely challenging to establish in resource-poor and low-income countries, due to their high capital investment and operating costs. This makes the fabrication of EWOD-DMF platforms extremely challenging in low-income countries, where such platforms are most needed for many applications such as point-of-care testing applications. To address this challenge, we present a low-cost and simple fabrication procedure for EWOD-DMF electrode arrays, which can be performed anywhere with a commercial office inkjet printer without the need of expensive cleanroom facilities. We demonstrate the utility of our platform to move and mix droplets of different reagents and physiologically conductive buffers, thereby showing its capability to potentially perform a variety of biochemical assays. By combining our low-cost, inkjet-printed EWOD-DMF platform with smartphone imaging technology and a compact control system for droplet manipulation, we also demonstrate a portable and hand-held device which can be programmed to potentially perform a variety of biochemical assays.

Author(s):  
John P. Sibbitt ◽  
Mei He

Microfluidic lab-on-a-chip (MLOC) technology is a promising approach for point-of-care (POC) diagnosis; low reagent consumption, high sensitivity and quick analysis time are the most prominent benefits. However, microfabrication of MLOCs utilizes specialized techniques and infrastructure, making conventional fabrication time consuming and difficult. While relatively inexpensive production techniques exist for POC diagnoses, such as replication of polymer-based (e.g., PDMS) microfluidic POC devices on lithographic molds, this approach has limitations including: further hydrophilic surface modifications of PDMS, inability to change lithographic mold Z dimensions, and slow prototyping. In contrast, stereo-lithographical (SLA) printing can integrate all of the necessary fabrication resources in one instrument, allowing highly versatile microfluidic devices to be made at low cost. In this paper, we report two microfabrication approaches of microfluidics utilizing (SLA) 3D printing technology: I) Direct SLA printing of channels and structures of a monolithic microfluidic POC device; II) Indirect fabrication, utilizing SLA 3D printed molds for PDMS based microfluidic device replication. Additionally, we discuss previous work providing a proof of concept of applications in POC diagnosis, using direct 3D printing fabrication (approach I). The robustness and simplicity of these protocols allow integrating 3D design and microfabrication with smartphone-based disease diagnosis as a stand-alone system, offering strong adaptability for establishing diagnostic capacity in resource-limited areas and low-income countries.


Micromachines ◽  
2020 ◽  
Vol 11 (9) ◽  
pp. 880
Author(s):  
Mohamed Yafia ◽  
Amir M. Foudeh ◽  
Maryam Tabrizian ◽  
Homayoun Najjaran

In this work, the laser-scribing technique was used as a low-cost, rapid and facile method for fabricating digital microfluidic (DMF) systems. Laser-scribed graphene (LSG) electrodes are directly synthesized on flexible substrates to pattern the DMF electrode arrays. This facilitates the DMF electrodes’ fabrication process by eliminating many microfabrication steps. An electrowetting test was performed to investigate the effectiveness of the LSG DMF electrodes in changing the contact angles of droplets. Different DMF operations were successfully performed using the proposed LSG DMF chips in both open and closed DMF systems. The quality and output resolution were examined to assess the performance of such patterned electrodes in the DMF systems. To verify the efficacy of the LSG DMF chips, a one-step direct assay for the detection of Legionellapneumophila deoxyribonucleic acid (DNA) was performed on the chip without the need for any washing step. The high specificity in distinguishing a single-nucleotide mismatch was achieved by detecting target DNA concentrations as low as 1 nM. Our findings suggest that the proposed rapid and easy fabrication method for LSG DMF electrodes offers a great platform for low-cost and easily accessible point-of-care diagnostic devices.


Diagnostics ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1352
Author(s):  
Darius Riziki Martin ◽  
Nicole Remaliah Sibuyi ◽  
Phumuzile Dube ◽  
Adewale Oluwaseun Fadaka ◽  
Ruben Cloete ◽  
...  

The transmission of Tuberculosis (TB) is very rapid and the burden it places on health care systems is felt globally. The effective management and prevention of this disease requires that it is detected early. Current TB diagnostic approaches, such as the culture, sputum smear, skin tuberculin, and molecular tests are time-consuming, and some are unaffordable for low-income countries. Rapid tests for disease biomarker detection are mostly based on immunological assays that use antibodies which are costly to produce, have low sensitivity and stability. Aptamers can replace antibodies in these diagnostic tests for the development of new rapid tests that are more cost effective; more stable at high temperatures and therefore have a better shelf life; do not have batch-to-batch variations, and thus more consistently bind to a specific target with similar or higher specificity and selectivity and are therefore more reliable. Advancements in TB research, in particular the application of proteomics to identify TB specific biomarkers, led to the identification of a number of biomarker proteins, that can be used to develop aptamer-based diagnostic assays able to screen individuals at the point-of-care (POC) more efficiently in resource-limited settings.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3774
Author(s):  
Pavlos Topalidis ◽  
Cristina Florea ◽  
Esther-Sevil Eigl ◽  
Anton Kurapov ◽  
Carlos Alberto Beltran Leon ◽  
...  

The purpose of the present study was to evaluate the performance of a low-cost commercial smartwatch, the Xiaomi Mi Band (MB), in extracting physical activity and sleep-related measures and show its potential use in addressing questions that require large-scale real-time data and/or intercultural data including low-income countries. We evaluated physical activity and sleep-related measures and discussed the potential application of such devices for large-scale step and sleep data acquisition. To that end, we conducted two separate studies. In Study 1, we evaluated the performance of MB by comparing it to the GT3X (ActiGraph, wGT3X-BT), a scientific actigraph used in research, as well as subjective sleep reports. In Study 2, we distributed the MB across four countries (Austria, Germany, Cuba, and Ukraine) and investigated physical activity and sleep among these countries. The results of Study 1 indicated that MB step counts correlated highly with the scientific GT3X device, but did display biases. In addition, the MB-derived wake-up and total-sleep-times showed high agreement with subjective reports, but partly deviated from GT3X predictions. Study 2 revealed similar MB step counts across countries, but significant later wake-up and bedtimes for Ukraine than the other countries. We hope that our studies will stimulate future large-scale sensor-based physical activity and sleep research studies, including various cultures.


2018 ◽  
Vol 49 (3) ◽  
pp. 201-212
Author(s):  
Ana Carolina Amaya Arias ◽  
Óscar Zuluaga ◽  
Douglas Idárraga ◽  
Javier Hernando Eslava Schmalbach

Introduction: Most maternal deaths that occur in developing countries are considered unfair and can be avoided. In 2008, The World Health Organization (WHO) proposed a checklist for childbirth care, in order to assess whether a simple, low-cost intervention had an impact on maternal and neonatal mortality in low-income countries. Objective: To translate, adapt and validate the content of the WHO Safe Childbirth Checklist (SCC) for its use in Colombia Methods: The checklist was translated and adapted to the Colombian context. It was subsequently validated by a panel of experts composed of 17 health workers with experience in maternal and neonatal care and safety. Reliability among judges was estimated (Rwg) and items were modified or added to each section of the list according to the results. Results: Modifications were made to 28 items, while 19 new items were added, and none was removed. The most important modifications were made to the management guidelines included in each item, and the items added refer to risks inherent to our environment. Conclusion: The Colombian version of the SCC will be a useful tool to improve maternal and neonatal care and thereby contribute to reducing maternal and neonatal morbidity and mortality in our country.


Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 429 ◽  
Author(s):  
Charles Nanseu-Njiki ◽  
Willis Gwenzi ◽  
Martin Pengou ◽  
Mohammad Rahman ◽  
Chicgoua Noubactep

Inadequate access to safe drinking water is one of the most pervasive problems currently afflicting the developing world. Scientists and engineers are called to present affordable but efficient solutions, particularly applicable to small communities. Filtration systems based on metallic iron (Fe0) are discussed in the literature as one such viable solution, whether as a stand-alone system or as a complement to slow sand filters (SSFs). Fe0 filters can also be improved by incorporating biochar to form Fe0-biochar filtration systems with potentially higher contaminant removal efficiencies than those based on Fe0 or biochar alone. These three low-cost and chemical-free systems (Fe0, biochar, SSFs) have the potential to provide universal access to safe drinking water. However, a well-structured systematic research is needed to design robust and efficient water treatment systems based on these affordable filter materials. This communication highlights the technology being developed to use Fe0-based systems for decentralized safe drinking water provision. Future research directions for the design of the next generation Fe0-based systems are highlighted. It is shown that Fe0 enhances the efficiency of SSFs, while biochar has the potential to alleviate the loss of porosity and uncertainties arising from the non-linear kinetics of iron corrosion. Fe0-based systems are an affordable and applicable technology for small communities in low-income countries, which could contribute to attaining self-reliance in clean water supply and universal public health.


2014 ◽  
Vol 5 (1) ◽  
pp. 28-38 ◽  
Author(s):  
L. Guerrero-Latorre ◽  
M. Rusiñol ◽  
A. Hundesa ◽  
M. Garcia-Valles ◽  
S. Martinez ◽  
...  

Household-based water treatment (HWT) is increasingly being promoted to improve water quality and, therefore, health status in low-income countries. Ceramic water filters (CWFs) are used in many regions as sustainable HWT and have been proven to meet World Health Organization (WHO) microbiological performance targets for bacterial removal (2–4 log); however, the described viral removal efficiencies are insufficient to significantly reduce the associated risk of viral infection. With the objective of improving the viral removal efficiencies of ceramic water filters, new prototypes with different oxide compositions and firing atmospheres have been developed and evaluated. For removal efficiencies human adenoviruses, MS2 bacteriophage and Escherichia coli were quantified in all prototypes. A new model of CWF that was fired in a reductive atmosphere presented virus and bacteria removal efficiencies greater than 3.0 log and 2.5 log, respectively, which would fulfill the viral targets that are recommended by the WHO. Ceramic characterization of the selected filters, which were fired in a reductive atmosphere, showed that a larger specific surface area than those of control filters and higher fraction of a positive Z-potential fraction are the most likely explanations for this increase in virus removal.


MRS Advances ◽  
2018 ◽  
Vol 3 (26) ◽  
pp. 1475-1483 ◽  
Author(s):  
Udayan Umapathi ◽  
Samantha Chin ◽  
Patrick Shin ◽  
Dimitris Koutentakis ◽  
Hiroshi Ishii

ABSTRACTDroplet based microfluidics (digital microfluidics) with Electrowetting on dielectric (EWOD) has gained popularity with the promise of being technology for a true lab-on-chip device with applications spanning across assays/library prep, next-gen sequencing and point-of-care diagnostics. Most electrowetting device architecture are linear electrode arrays with a shared path for droplets, imposing serious limitations -- cross contamination and limited number of parallel operations. Our work is in addressing these issues through large 2D grid arrays with direct addressability providing flexible programmability.Scaling electrowetting to larger arrays still remains a challenge due to complex and expensive cleanroom fabrication of microfluidic devices. We take the approach of using inexpensive PCB manufacturing, investigate challenges and solutions for scaling electrowetting to large area droplet manipulation. PCB manufactured electrowetting arrays impose many challenges due to the irregularities from process and materials used. These challenges generally relate to preparing the surface that interfaces with droplets -- a dielectric material on the electrodes and the top most hydrophobic coating that interfaces with the droplets. A requirement for robust droplet manipulation with EWOD is thin (<10um) hydrophobic dielectric material which does not break down at droplet actuation voltages (AC/DC, 60V to 200V) and has a no droplet pinning. For this, we engineered materials specifically for large area PCBs.Traditionally, digital microfluidic devices sandwich droplets between two plates and have focussed on sub-microliter droplet volumes. In our approach, droplets are on an open surface with which we are able to manipulate droplets in microliter and milliliter volumes. With milliliter droplet manipulation ability on our electrowetting device, we demonstrate “digital millifluidics”. Finally, we report the performance of our device and to motivate the need for large open arrays we show an example of running multiple parallel biological experiments.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 3373-3373
Author(s):  
Arwa Fraiwan ◽  
Muhammad Noman Hasan ◽  
Ran An ◽  
Julia Z. Xu ◽  
Amy J. Rezac ◽  
...  

Introduction: Nearly 24% of the world's population carry hemoglobin (Hb) gene variants, with the large majority of affected births occurring in low-income countries. The most prevalent structural Hb variants are the recessive β-globin gene mutations, βS or S, βC or C, and βE or E1. Hb S mutation is prevalent in sub-Saharan Africa and in Central India. Hb C is common in West Africa, and Hb E is common in Southeast Asia and in India. Homozygotes or compound heterozygotes with βS (e.g., Hb SS or SC) have sickle cell disease (SCD), a chronic sickling disorder associated with pain, chronic multi-organ damage, and high mortality. While Hb EE causes only a mild microcytic anemia, Hb E in combination with β-thalassemia can lead to transfusion dependent thalassemia. Though carriers are typically asymptomatic, they may pass the mutations to their offspring. Screening is needed so that these disorders can be diagnosed early and managed in a timely manner2. For example, in low-income countries, due to lack of nationwide screening and comprehensive care programs, up to 80% of babies born with SCD are undiagnosed and less than half of them survive beyond 5 years of age2. The unmet need for affordable, portable, accurate point-of-care tests to facilitate decentralized hemoglobin testing in resource-constrained countries is well-recognized 2,3. Here, we present international multi-site clinical validation results and high diagnostic accuracy of the 'HemeChip' (Fig. 1), an affordable, 10-minute point-of-care microchip electrophoresis test for identifying common Hb variants S, C, and E. Methods: Institutional Review Board approvals were obtained at each study site, and blood samples were collected as part of the standard clinical care. Tests were performed by local users, including healthcare workers and clinical laboratory personnel. 315 children (6 weeks to 5 years of age) were tested in Kano, Nigeria. Study participants were enrolled at three hospitals, Amino Kano Teaching Hospital, Murtala Mohammed Specialist Hospital, and Hasiya Bayero Pediatric Hospital. 124 subjects (7 weeks to 63 years old) were included in the study at Siriraj Thalassemia Center in Bangkok, Thailand. 298 subjects (8 months to 65 years old) were tested at a referral testing facility of ICMR-National Institute of Research in Tribal Health, located at Late Baliram Kashayap Memorial Medical College, Jagdalpur, Chhattisgarh, India. Blood samples were tested with both HemeChip and the standard reference methods, high performance liquid chromatography or cellulose acetate electrophoresis. Reference test results were not available to the HemeChip users. Similarly, HemeChip test results were not available to the users of the standard reference tests. Clinical validation studies presented here were performed with a fully functional, portable HemeChip prototype developed at Case Western Reserve University (Fig. 1A). A commercial product has been developed based on this technology by Hemex Health Inc. under the product name, GazelleTM(Fig. 1B). Results and Discussion: Among the total 768 tests performed with HemeChip in all test sites, 732 were valid tests, as defined by the Standards for Reporting Diagnostic Accuracy (STARD)4. HemeChip correctly identified all subjects with Hb SS, Hb SC, Hb AS, Hb AE, and Hb EE with 100% accuracy (Table 1). Nine subjects with normal Hb (Hb AA) were identified as HbSS in Nigeria. No subjects with disease were identified as normal or trait by HemeChip. Three subjects with compound heterozygous Hb Sβ-thalassemia (2 subjects with Hb Sβ+-thalassemia, 1 subject with Hb Sβ0-thalassemia) were identified as Hb SS. Sensitivity was 100% for all Hb types tested. Specificity was 98.7% for Hb SS versus other Hb types, and 100% for all other Hb types tested. HemeChip displayed an overall diagnostic accuracy of 98.4% in comparison to standard reference methods for the Hb variants tested in all clinical testing sites (Table 1). HemeChip is a versatile point-of-care system that enables affordable, accurate, decentralized hemoglobin testing in resource-limited settings. References: 1. Weatherall DJ, Clegg JB. Bull World Health Organ. 2001;79(8):704-712. 2. Mburu J, Odame I. International Journal of Laboratory Hematology. 2019;41(S1):82-88. 3. Alapan Y, Fraiwan A, Kucukal E, et al. Expert Review of Medical Devices. 2016;13(12):1073-1093. 4. Bossuyt PM, Reitsma JB, Bruns DE, et al. BMJ : British Medical Journal. 2015;351:h5527. Disclosures Fraiwan: Hemex Health, Inc.: Equity Ownership, Patents & Royalties. Hasan:Hemex Health, Inc.: Equity Ownership, Patents & Royalties. An:Hemex Health, Inc.: Patents & Royalties. Thota:Hemex Health, Inc.: Employment. Piccone:Hemex Health, Inc.: Patents & Royalties. Little:Hemex Health, Inc.: Patents & Royalties; GBT: Research Funding. Gurkan:Hemex Health, Inc.: Consultancy, Employment, Equity Ownership, Patents & Royalties, Research Funding.


2017 ◽  
Vol 4 ◽  
pp. 205566831770642
Author(s):  
Kazuhiko Sasaki ◽  
Jutamat Pinitlertsakun ◽  
Pakwan Nualnim ◽  
Gary Guerra ◽  
Yuttapichai Sansook ◽  
...  

Background The alignment of the lower limb prosthesis is an integral part of the prosthetic fitting. A properly aligned prosthesis contributes to optimal gait and overall function of the patient. The current offering of alignment componentry is expensive for low-income countries. The purpose of this study was to develop a lightweight and low-cost alignment coupler for the lower limb prosthesis. Methods An alignment coupler called the reversible adjustable coupling was designed and manufactured. Measurements of total anterior/posterior and medial/lateral and rotation in prostheses were recorded and mechanical testing performed. Swiftness and difficulty of use was also recorded. Results The reversible adjustable coupling permitted acceptable ranges of anterior/posterior and medial/lateral translation and 30° of internal and external rotation of prosthetic componentry. Repetitive loading of the coupling at a speed of 1 Hz under 1.28 kN load for 2000 cycles was successful, as were static and strength tests. Discussion The coupler provided acceptable ranges of anterior/posterior and medial/lateral and rotation adjustment and is acceptable for potential use in the alignment of both exoskeletal and endoskeletal prosthesis. The final weight of the component was 166 g and cost of $55.00 USD is affordable for low-income countries for use in clinical and educational settings.


Sign in / Sign up

Export Citation Format

Share Document