scholarly journals Near-Infrared Spectroscopy for Monitoring Sternocleidomastoid Muscular Oxygenation during Isometric Flexion for Patients with Mild Nonspecific Neck Pain: A Pilot Study

Sensors ◽  
2020 ◽  
Vol 20 (8) ◽  
pp. 2197
Author(s):  
Chia-Chi Yang ◽  
Po-Ching Yang ◽  
Jia-Jin J. Chen ◽  
Yi-Horng Lai ◽  
Chia-Han Hu ◽  
...  

Since there is merit in noninvasive monitoring of muscular oxidative metabolism for near-infrared spectroscopy in a wide range of clinical scenarios, the present study attempted to evaluate the clinical usability for featuring the modulatory strategies of sternocleidomastoid muscular oxygenation using near-infrared spectroscopy in mild nonspecific neck pain patients. The muscular oxygenation variables of the dominant or affected sternocleidomastoid muscles of interest were extracted at 25% of the maximum voluntary isometric contraction from ten patients (5 males and 5 females, 23.6 ± 4.2 years) and asymptomatic individuals (6 males and 4 females, 24.0 ± 5.1 years) using near-infrared spectroscopy. Only a shorter half-deoxygenation time of oxygen saturation during a sternocleidomastoid isometric contraction was noted in patients compared to asymptomatic individuals (10.43 ± 1.79 s vs. 13.82 ± 1.42 s, p < 0.001). Even though the lack of statically significant differences in most of the muscular oxygenation variables failed to refine the definite pathogenic mechanisms underlying nonspecific neck pain, the findings of modulatory strategies of faster deoxygenation implied that near-infrared spectroscopy appears to have practical potential to provide relevant physiological information regarding muscular oxidative metabolism and constituted convincing preliminary evidences of the adaptive manipulations rather than pathological responses of oxidative metabolism capacity of sternocleidomastoid muscles in nonspecific neck patients with mild disability.

Author(s):  
Martin Smith

Near-infrared spectroscopy (NIRS) has potential as a non-invasive brain monitor in a wide range of clinical scenarios. In the last decade, there has been a rapid expansion of clinical experience using NIRS to monitor cerebral oxygenation, particularly in cardiac surgery, where there is some evidence that NIRS-guided brain protection protocols might lead to a reduction in peri-operative neurological complications. There are no data to support the wider application of NIRS to monitor cerebral oxygenation during routine anaesthesia and surgery, and its application in brain injury, where it might be expected to have a key monitoring role, is as yet undefined. Technological developments, including the introduction of broadband and time-resolved spectrometers that are capable of reliably measuring changes in oxidized cytochrome c oxidase, offer real potential for a single NIRS-based device to provide multi-site, regional monitoring of cerebral metabolic status as well as oxygenation and haemodynamics.


2016 ◽  
Vol 121 (3) ◽  
pp. 699-708 ◽  
Author(s):  
Simone Porcelli ◽  
Mauro Marzorati ◽  
Lucia Morandi ◽  
Bruno Grassi

Aerobic training can be effective in patients with mitochondrial myopathies (MM) and McArdle's disease (McA). The aim of the study was to use noninvasive functional evaluation methods, specifically aimed at skeletal muscle oxidative metabolism, to evaluate the effects of an aerobic exercise training (cycle ergometer, 12 wk, 4 days/wk, ∼65-70% of maximal heart rate) in 6 MM and 7 McA. Oxygen uptake and skeletal muscle vastus lateralis fractional O2 extraction by near-infrared spectroscopy were assessed during incremental and low-intensity constant work rate (CWR) exercises before (BEFORE) and at the end (AFTER) of training. Peak O2 uptake increased significantly with training both in MM [14.7 ± 1.2 vs. 17.6 ± 1.4 ml·kg−1·min−1 (mean ± SD)] and in McA (18.5 ± 1.8 ml·kg−1·min−1 vs. 21.6 ± 1.9). Peak skeletal muscle fractional O2 extraction increased with training both in MM (22.0 ± 6.7 vs. 32.6 ± 5.9%) and in McA (18.5 ± 6.2 vs. 37.2 ± 7.2%). During low-intensity CWR in both MM and McA: V̇o2 kinetics became faster in AFTER, but only in the patients with slow V̇o2 kinetics in BEFORE; the transient overshoot in fractional O2 extraction kinetics disappeared. The level of habitual physical activity was not higher 3 mo after training (FOLLOW-UP vs. PRE). In MM and McA patients a home-based aerobic training program significantly attenuated the impairment of skeletal muscle oxidative metabolism and improved variables associated with exercise tolerance. Our findings indicate that in MM and McA patients near-infrared spectroscopy and V̇o2 kinetics can effectively detect the functional improvements obtained by training.


1998 ◽  
Vol 88 (1) ◽  
pp. 58-65 ◽  
Author(s):  
Lindsey C. Henson ◽  
Carolyn Calalang ◽  
John A. Temp ◽  
Denham S. Ward

Background A cerebral oximeter measures oxygen saturation of brain tissue noninvasively by near infrared spectroscopy. The accuracy of a commercially available oximeter was tested in healthy volunteers by precisely controlling end-tidal oxygen (P[ET]O2) and carbon dioxide (P[ET]CO2) tensions to alter global cerebral oxygen saturation. Methods In 30 healthy volunteers, dynamic end-tidal forcing was used to produce step changes in P[ET]O2 resulting in arterial saturation ranging from approximately 70% to 100% under conditions of controlled normocapnia (each person's resting P[ET]CO2) or hypercapnia (resting plus 7-10 mmHg). Blood arterial (SaO2) and jugular bulb venous (S[jv]O2) saturations during each P(ET)O2 interval were determined by co-oximetry. The cerebral oximeter reading (rSO2) and an estimated jugular venous saturation (S[jv]O2), derived from a combination of SaO2 and rSO2, were compared with the measured S(jv)O2. Results The S(jv)O2 was significantly higher with hypercapnia than with normocapnia for the same SaO2. The rSO2 and S(jv)O2 were both highly correlated with S(jv)O2 for individual volunteers (mean r2 = 0.91 for each relation); however, the slopes and intercepts varied widely among volunteers. In three of them, the cerebral oximeter substantially underestimated the measured S(jv)O2. Conclusions During isocapnic hypoxia in healthy persons, cerebral oxygenation as estimated by near infrared spectroscopy precisely tracks changes in measured S(jv)O2 within individuals, but the relation exhibits a wide range of slopes and intercepts. Therefore the clinical utility of the device is limited to situations in which tracking trends in cerebral oxygenation would be acceptable.


2015 ◽  
Vol 118 (6) ◽  
pp. 783-793 ◽  
Author(s):  
Ioannis Vogiatzis ◽  
Helmut Habazettl ◽  
Zafeiris Louvaris ◽  
Vasileios Andrianopoulos ◽  
Harrieth Wagner ◽  
...  

Heterogeneity in the distribution of both blood flow (Q̇) and O2 consumption (V̇o2) has not been assessed by near-infrared spectroscopy in exercising normal human muscle. We used near-infrared spectroscopy to measure the regional distribution of Q̇ and V̇o2 in six trained cyclists at rest and during constant-load exercise (unloaded pedaling, 20%, 50%, and 80% of peak Watts) in both normoxia and hypoxia (inspired O2 fraction = 0.12). Over six optodes over the upper, middle, and lower vastus lateralis, we recorded 1) indocyanine green dye inflow after intravenous injection to measure Q̇; and 2) fractional tissue O2 saturation (StiO2) to estimate local V̇o2-to-Q̇ ratios (V̇o2/Q̇). Varying both exercise intensity and inspired O2 fraction provided a (directly measured) femoral venous O2 saturation range from about 10 to 70%, and a correspondingly wide range in StiO2. Mean Q̇-weighted StiO2 over the six optodes related linearly to femoral venous O2 saturation in each subject. We used this relationship to compute local muscle venous blood O2 saturation from StiO2 recorded at each optode, from which local V̇o2/Q̇ could be calculated by the Fick principle. Multiplying regional V̇o2/Q̇ by Q̇ yielded the corresponding local V̇o2. While six optodes along only in one muscle may not fully capture the extent of heterogeneity, relative dispersion of both Q̇ and V̇o2 was ∼0.4 under all conditions, while that for V̇o2/Q̇ was minimal (only ∼0.1), indicating in fit young subjects 1) a strong capacity to regulate Q̇ according to regional metabolic need; and 2) a likely minimal impact of heterogeneity on muscle O2 availability.


2007 ◽  
Vol 12 (6) ◽  
pp. 062105 ◽  
Author(s):  
Takafumi Hamaoka ◽  
Kevin K. McCully ◽  
Valentina Quaresima ◽  
Katsuyuki Yamamoto ◽  
Britton Chance