scholarly journals A High-Performance 2.5 μm Charge Domain Global Shutter Pixel and Near Infrared Enhancement with Light Pipe Technology

Sensors ◽  
2020 ◽  
Vol 20 (1) ◽  
pp. 307 ◽  
Author(s):  
Ikuo Mizuno ◽  
Masafumi Tsutsui ◽  
Toshifumi Yokoyama ◽  
Tatsuya Hirata ◽  
Yoshiaki Nishi ◽  
...  

We developed a new 2.5 μm global shutter (GS) pixel using a 65 nm process with an advanced light pipe (LP) structure. This is the world’s smallest charge domain GS pixel reported so far. This new developed pixel platform is a key enabler for ultra-high resolution sensors, industrial cameras with wide aperture lenses, and low form factors optical modules for mobile applications. The 2.5 μm GS pixel showed excellent optical performances: 68% quantum efficiency (QE) at 530 nm, ±12.5 degrees angular response (AR), and quite low parasitic light sensitivity (PLS)—10,400 1/PLS with the F#2.8 lens. In addition, we achieved an extremely low memory node (MN) dark current 13 e−/s at 60 °C by fully pinned MN. Furthermore, we studied how the LP technology contributes to the improvement of the modulation transfer function (MTF) in near infrared (NIR) enhanced GS pixel. The 2.8 μm GS pixel using a p-substrate showed 109 lp/mm MTF@50% at 940 nm, which is 1.6 times better than that without an LP. The MTF can be more enhanced by the combination of the LP and the deep photodiode (PD) electrically isolated from the substrate. We demonstrated the advantage of using LP technology and our advanced stacked deep photodiode (SDP) technology together. This unique combination showed an improvement of more than 100% in NIR QE while maintaining an MTF that is close to the theoretical Nyquist limit (MTF @50% = 156 lp/mm).

2021 ◽  
Author(s):  
Jing Liu ◽  
Peilin Liu ◽  
Dengyang Chen ◽  
Tailong Shi ◽  
Xixi Qu ◽  
...  

Abstract Near-infrared (NIR, 0.7–1.4 µm) imagers have wide applications in night surveillance, material sorting, machine vision and potentially automatic driving. However, limited by the high-temperature processing and requirement of single-crystalline substrate, so far flip-chip is the dominant way to connect infrared photodiodes and silicon-based readout integrated circuit (ROIC) to produce infrared imagers, suffering from complicated process and ultra-high cost and hence limiting their widespread applications in the market. Here we report the monolithic integration of colloidal quantum dots (CQD) photodiodes with complementary metal-oxide-semiconductor (CMOS) ROIC, operating as a low-cost and high-performance imager. The CQD photodetector is well designed with a CMOS-compatible structure, demonstrating a response spectral range of 400–1300 nm, a detectivity of 2.1×1012 Jones at room temperature, a -3dB bandwidth of 140 kHz and a linear dynamic range over 100 dB. The CQD imager can identify materials, inspect apple scar and veins with a large size of 640×512 pixels and a spatial resolution of 40 lp/mm at a modulation transfer function of 50%. Monolithic integration significantly reduces the cost without sacrificing performance, thus providing huge potential for the ubiquitous deployment of infrared imagers.


Author(s):  
R. Levi-Setti ◽  
J. M. Chabala ◽  
R. Espinosa ◽  
M. M. Le Beau

We have shown previously that isotope-labelled nucleotides in human metaphase chromosomes can be detected and mapped by imaging secondary ion mass spectrometry (SIMS), using the University of Chicago high resolution scanning ion microprobe (UC SIM). These early studies, conducted with BrdU- and 14C-thymidine-labelled chromosomes via detection of the Br and 28CN- (14C14N-> labelcarrying signals, provided some evidence for the condensation of the label into banding patterns along the chromatids (SIMS bands) reminiscent of the well known Q- and G-bands obtained by conventional staining methods for optical microscopy. The potential of this technique has been greatly enhanced by the recent upgrade of the UC SIM, now coupled to a high performance magnetic sector mass spectrometer in lieu of the previous RF quadrupole mass filter. The high transmission of the new spectrometer improves the SIMS analytical sensitivity of the microprobe better than a hundredfold, overcoming most of the previous imaging limitations resulting from low count statistics.


2021 ◽  
Vol 7 (2) ◽  
pp. eabe3097
Author(s):  
Hongwei Sheng ◽  
Jingjing Zhou ◽  
Bo Li ◽  
Yuhang He ◽  
Xuetao Zhang ◽  
...  

It has been an outstanding challenge to achieve implantable energy modules that are mechanically soft (compatible with soft organs and tissues), have compact form factors, and are biodegradable (present for a desired time frame to power biodegradable, implantable medical electronics). Here, we present a fully biodegradable and bioabsorbable high-performance supercapacitor implant, which is lightweight and has a thin structure, mechanical flexibility, tunable degradation duration, and biocompatibility. The supercapacitor with a high areal capacitance (112.5 mF cm−2 at 1 mA cm−2) and energy density (15.64 μWh cm−2) uses two-dimensional, amorphous molybdenum oxide (MoOx) flakes as electrodes, which are grown in situ on water-soluble Mo foil using a green electrochemical strategy. Biodegradation behaviors and biocompatibility of the associated materials and the supercapacitor implant are systematically studied. Demonstrations of a supercapacitor implant that powers several electronic devices and that is completely degraded after implantation and absorbed in rat body shed light on its potential uses.


SLEEP ◽  
2020 ◽  
Author(s):  
Evan D Chinoy ◽  
Joseph A Cuellar ◽  
Kirbie E Huwa ◽  
Jason T Jameson ◽  
Catherine H Watson ◽  
...  

Abstract Study Objectives Consumer sleep-tracking devices are widely used and becoming more technologically advanced, creating strong interest from researchers and clinicians for their possible use as alternatives to standard actigraphy. We therefore tested the performance of many of the latest consumer sleep-tracking devices, alongside actigraphy, versus the gold-standard sleep assessment technique, polysomnography (PSG). Methods In total, 34 healthy young adults (22 women; 28.1 ± 3.9 years, mean ± SD) were tested on three consecutive nights (including a disrupted sleep condition) in a sleep laboratory with PSG, along with actigraphy (Philips Respironics Actiwatch 2) and a subset of consumer sleep-tracking devices. Altogether, four wearable (Fatigue Science Readiband, Fitbit Alta HR, Garmin Fenix 5S, Garmin Vivosmart 3) and three non-wearable (EarlySense Live, ResMed S+, SleepScore Max) devices were tested. Sleep/wake summary and epoch-by-epoch agreement measures were compared with PSG. Results Most devices (Fatigue Science Readiband, Fitbit Alta HR, EarlySense Live, ResMed S+, SleepScore Max) performed as well as or better than actigraphy on sleep/wake performance measures, while the Garmin devices performed worse. Overall, epoch-by-epoch sensitivity was high (all ≥0.93), specificity was low-to-medium (0.18-0.54), sleep stage comparisons were mixed, and devices tended to perform worse on nights with poorer/disrupted sleep. Conclusions Consumer sleep-tracking devices exhibited high performance in detecting sleep, and most performed equivalent to (or better than) actigraphy in detecting wake. Device sleep stage assessments were inconsistent. Findings indicate that many newer sleep-tracking devices demonstrate promising performance for tracking sleep and wake. Devices should be tested in different populations and settings to further examine their wider validity and utility.


Author(s):  
Yun Zhao ◽  
Xiaoqiang Feng ◽  
Menghan Zhao ◽  
Xiaohu Zheng ◽  
Zhiduo Liu ◽  
...  

Employing C3N QD-integrated single-crystal graphene, photodetectors exhibited a distinct photocurrent response at 1550 nm. The photocurrent map revealed that the fast response derive from C3N QDs that enhanced the local electric field near graphene.


CrystEngComm ◽  
2021 ◽  
Author(s):  
Mingming Jiang ◽  
Fupeng Zhang ◽  
Kai Tang ◽  
Peng Wan ◽  
Caixia Kan

Achieving electrically-driven exciton-polaritons has drawn substantial attention toward developing ultralow-threshold coherent light sources, containing polariton laser devices and high-performance light-emitting diodes (LEDs). In this work, we demonstrate an electrically driven...


2019 ◽  
Vol 485 (3) ◽  
pp. 3370-3377 ◽  
Author(s):  
Lehman H Garrison ◽  
Daniel J Eisenstein ◽  
Philip A Pinto

Abstract We present a high-fidelity realization of the cosmological N-body simulation from the Schneider et al. code comparison project. The simulation was performed with our AbacusN-body code, which offers high-force accuracy, high performance, and minimal particle integration errors. The simulation consists of 20483 particles in a $500\ h^{-1}\, \mathrm{Mpc}$ box for a particle mass of $1.2\times 10^9\ h^{-1}\, \mathrm{M}_\odot$ with $10\ h^{-1}\, \mathrm{kpc}$ spline softening. Abacus executed 1052 global time-steps to z = 0 in 107 h on one dual-Xeon, dual-GPU node, for a mean rate of 23 million particles per second per step. We find Abacus is in good agreement with Ramses and Pkdgrav3 and less so with Gadget3. We validate our choice of time-step by halving the step size and find sub-percent differences in the power spectrum and 2PCF at nearly all measured scales, with ${\lt }0.3{{\ \rm per\ cent}}$ errors at $k\lt 10\ \mathrm{Mpc}^{-1}\, h$. On large scales, Abacus reproduces linear theory better than 0.01 per cent. Simulation snapshots are available at http://nbody.rc.fas.harvard.edu/public/S2016.