scholarly journals Synthesis of Ni-Co Hydroxide Nanosheets Constructed Hollow Cubes for Electrochemical Glucose Determination

Sensors ◽  
2019 ◽  
Vol 19 (13) ◽  
pp. 2938 ◽  
Author(s):  
Fengchao Sun ◽  
Shutao Wang ◽  
Yuqi Wang ◽  
Jingtong Zhang ◽  
Xinping Yu ◽  
...  

Hierarchical Ni-Co double transition metal hydroxide nanosheets have been explored as an effective strategy for the design of nonenzymatic glucose sensors. Ni-Co hydroxide nanosheets constructed hollow cubes were successfully synthesized by using Cu2O cubes as templates and subsequently etched by Na2S2O3 to achieve a hollow cubic structure. The molar ratio between Ni and Co was tuned by varying the precursor ratio of NiCl2 and CoCl2. It was observed by transmission electron microscopy (TEM) that the increasing Ni precursor resulted in particle morphology, and the increasing ratio of the Co precursor resulted in more lamellar morphology. The sample with the composition of Ni0.7Co0.3(OH)2 displayed the best performance for glucose sensing with high selectivity (1541 μA mM–1 cm–2), low detection limit (3.42 µM with S/N = 3), and reasonable selectivity. Similar strategies could be applied for the design of other electrode materials with high efficiency for nonenzymatic glucose determination.

NANO ◽  
2019 ◽  
Vol 14 (04) ◽  
pp. 1950045
Author(s):  
Fang Sun ◽  
Lehong Xing ◽  
Xihui Yang ◽  
Hailiang Huang ◽  
Lina Ning

In this study, CuO films with hollow cubic cages were prepared by a facile two-step procedure consisting of electrodeposition synthesis and subsequent direct calcination. First, Cu2O nanocubes were fabricated on ITO substrate through a simple electrodeposition procedure. Then, Cu2O nanocubes were converted to CuO hollow cubic cages without obvious morphological change through direct calcination. The obtained CuO cubic cages serving as active materials illustrated a favorable performance for nonenzymatic glucose sensing with high sensitivity of [Formula: see text]A[Formula: see text]mM[Formula: see text][Formula: see text]cm[Formula: see text] at a low applied potential of 0.50[Formula: see text]V, fast-response time (less than 3[Formula: see text]s), low detection limit of 1.0[Formula: see text][Formula: see text]M and wide linear range up from 2.0[Formula: see text][Formula: see text]M to 1.0[Formula: see text]mM ([Formula: see text]). Moreover, the good selectivity of the CuO cubic cages-based nonenzymatic glucose sensor against electroactive compounds such as ascorbic acid, uric acid and dopamine were also demonstrated. These good features indicate that the as-prepared CuO cubic cages can be used as promising electrode materials, which have a great potential in the development of sensitive and selective nonenzymatic glucose sensors.


2009 ◽  
Vol 81 (8) ◽  
pp. 1489-1498 ◽  
Author(s):  
Amreesh Chandra ◽  
Alexander J. Roberts ◽  
Eric Lam How Yee ◽  
Robert C. T. Slade

Nanostructured materials are extensively investigated for application in energy storage and power generation devices. This paper deals with the synthesis and characterization of nanomaterials based on oxides of vanadium and with their application as electrode materials for energy storage systems viz. supercapacitors. These nano-oxides have been synthesized using a hydrothermal route in the presence of templates: 1-hexadecylamine, Tweens and Brij types. Using templates during synthesis enables tailoring of the particle morphology and physical characteristics of synthesized powders. Broad X-ray diffraction peaks show the formation of nanoparticles, confirmed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) investigations. SEM studies show that a large range of nanostructures such as needles, fibers, particles, etc. can be synthesized. These particles have varying surface areas and electrical conductivity. Enhancement of surface area as much as seven times relative to surface areas of starting parent materials has been observed. These properties make such materials ideal candidates for application as electrode materials in supercapacitors. Assembly and characterization of supercapacitors based on electrodes containing these active nano-oxides are discussed. Specific capacitance of >100 F g–1 has been observed. The specific capacitance decreases with cycling: causes of this phenomenon are presented.


Chemosensors ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 1 ◽  
Author(s):  
A. B. M. Zakaria ◽  
Danuta Leszczynska

Amperometric hydrogen peroxide (H2O2) and glucose biosensors based on unzipped carbon nanotubes with modified glassy carbon electrode (GCE) have been successfully fabricated via a facile electrochemical oxidative method. In this work, we investigated the feasibility of this new form of carbon nanomaterial as a substrate electrode material for fabricating sensitive platform for H2O2 and glucose sensors. For this purpose, the manganese oxide (MnO2)/unzipped single-walled carbon nanotubes (SWCNTs) film was synthesized by the cyclic voltammetry method. The developed sensing film, MnO2/unzipped SWCNTs/GCE, displayed a satisfactory analytical performance for H2O2, including a wide linear range of 2.0 × 10−6 to 5.0 × 10−3 M with a detection limit of 0.31 × 10−6 M (10.7 ppb). This film was further applied for glucose sensing with a linearity range of 0.01 to 1.2 mM with a correlation coefficient of 0.9822 in the physiological pH (7.4). This facile, fast, environmentally-friendly, and economical preparation strategy of carbon nanomaterial-based electrode materials opens up the possibility of developing high quality biocompatible hydrogen peroxide and glucose sensors.


Author(s):  
O. L. Shaffer ◽  
M.S. El-Aasser ◽  
C. L. Zhao ◽  
M. A. Winnik ◽  
R. R. Shivers

Transmission electron microscopy is an important approach to the characterization of the morphology of multiphase latices. Various sample preparation techniques have been applied to multiphase latices such as OsO4, RuO4 and CsOH stains to distinguish the polymer phases or domains. Radiation damage by an electron beam of latices imbedded in ice has also been used as a technique to study particle morphology. Further studies have been developed in the use of freeze-fracture and the effect of differential radiation damage at liquid nitrogen temperatures of the latex particles embedded in ice and not embedded.Two different series of two-stage latices were prepared with (1) a poly(methyl methacrylate) (PMMA) seed and poly(styrene) (PS) second stage; (2) a PS seed and PMMA second stage. Both series have varying amounts of second-stage monomer which was added to the seed latex semicontinuously. A drop of diluted latex was placed on a 200-mesh Formvar-carbon coated copper grid.


Author(s):  
J. M. Cowley ◽  
R. Glaisher ◽  
J. A. Lin ◽  
H.-J. Ou

Some of the most important applications of STEM depend on the variety of imaging and diffraction made possible by the versatility of the detector system and the serial nature, of the image acquisition. A special detector system, previously described, has been added to our STEM instrument to allow us to take full advantage of this versatility. In this, the diffraction pattern in the detector plane may be formed on either of two phosphor screens, one with P47 (very fast) phosphor and the other with P20 (high efficiency) phosphor. The light from the phosphor is conveyed through a fiber-optic rod to an image intensifier and TV system and may be photographed, recorded on videotape, or stored digitally on a frame store. The P47 screen has a hole through it to allow electrons to enter a Gatan EELS spectrometer. Recently a modified SEM detector has been added so that high resolution (10Å) imaging with secondary electrons may be used in conjunction with other modes.


Author(s):  
K.M. Hones ◽  
P. Sheldon ◽  
B.G. Yacobi ◽  
A. Mason

There is increasing interest in growing epitaxial GaAs on Si substrates. Such a device structure would allow low-cost substrates to be used for high-efficiency cascade- junction solar cells. However, high-defect densities may result from the large lattice mismatch (∼4%) between the GaAs epilayer and the silicon substrate. These defects can act as nonradiative recombination centers that can degrade the optical and electrical properties of the epitaxially grown GaAs. For this reason, it is important to optimize epilayer growth conditions in order to minimize resulting dislocation densities. The purpose of this paper is to provide an indication of the quality of the epitaxially grown GaAs layers by using transmission electron microscopy (TEM) to examine dislocation type and density as a function of various growth conditions. In this study an intermediate Ge layer was used to avoid nucleation difficulties observed for GaAs growth directly on Si substrates. GaAs/Ge epilayers were grown by molecular beam epitaxy (MBE) on Si substrates in a manner similar to that described previously.


Materials ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 4715
Author(s):  
Adam Kubiak ◽  
Marta Kubacka ◽  
Elżbieta Gabała ◽  
Anna Dobrowolska ◽  
Karol Synoradzki ◽  
...  

The TiO2-Fe3O4 composite materials were fabricated via the hydrothermal-assisted technique. It was determined how the molar ratio of TiO2 to Fe3O4 influences the crystalline structure and morphology of the synthesized composite materials. The effect of the molar ratio of components on the antibacterial activity was also analyzed. On the basis of XRD patterns for the obtained titanium(IV) oxide-iron(II, III) oxide composites, the two separate crystalline forms—anatase and magnetite —were observed. Transmission electron microscopy revealed particles of cubic and tetragonal shape for TiO2 and spherical for Fe3O4. The results of low-temperature nitrogen sorption analysis indicated that an increase in the iron(II, III) oxide content leads to a decrease in the BET surface area. Moreover, the superparamagnetic properties of titanium(IV) oxide-iron(II, III) oxide composites should be noted. An important aim of the work was to determine the antibacterial activity of selected TiO2-Fe3O4 materials. For this purpose, two representative strains of bacteria, the Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus, were used. The titanium(IV) oxide-iron(II, III) oxide composites demonstrated a large zone of growth inhibition for both Gram-positive and Gram-negative bacteria. Moreover, it was found that the analyzed materials can be reused as antibacterial agents in three consecutive cycles with good results.


2021 ◽  
Vol 19 (1) ◽  
pp. 745-754
Author(s):  
Khoirina Dwi Nugrahaningtyas ◽  
Eddy Heraldy ◽  
Rachmadani ◽  
Yuniawan Hidayat ◽  
Indriana Kartini

Abstract The properties of three types of CoMo/USY catalysts with different synthesized methods have been studied. The sequential and co-impregnation methods followed by activation using calcination and reduction process have been conducted. The properties of the catalysts were examined using Fourier-transform-infrared (FTIR) spectroscopy, X-ray diffraction (XRD) with refinement, and surface area analyzer (SAA). The FTIR spectrum study revealed the enhanced intensity of its Bronsted acid site, and the XRD diffractogram pattern verified the composition of pure metals, oxides, and alloys in the catalyst. The SAA demonstrated the mesoporous features of the catalyst. Scanning electron microscopy showed an irregular particle morphology. Additional analysis using the transmission electron microscopy indicated that the metal has successfully impregnated without damaging the USY structure.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4672
Author(s):  
Mohamed H. Hassan ◽  
Cian Vyas ◽  
Bruce Grieve ◽  
Paulo Bartolo

The detection of glucose is crucial in the management of diabetes and other medical conditions but also crucial in a wide range of industries such as food and beverages. The development of glucose sensors in the past century has allowed diabetic patients to effectively manage their disease and has saved lives. First-generation glucose sensors have considerable limitations in sensitivity and selectivity which has spurred the development of more advanced approaches for both the medical and industrial sectors. The wide range of application areas has resulted in a range of materials and fabrication techniques to produce novel glucose sensors that have higher sensitivity and selectivity, lower cost, and are simpler to use. A major focus has been on the development of enzymatic electrochemical sensors, typically using glucose oxidase. However, non-enzymatic approaches using direct electrochemistry of glucose on noble metals are now a viable approach in glucose biosensor design. This review discusses the mechanisms of electrochemical glucose sensing with a focus on the different generations of enzymatic-based sensors, their recent advances, and provides an overview of the next generation of non-enzymatic sensors. Advancements in manufacturing techniques and materials are key in propelling the field of glucose sensing, however, significant limitations remain which are highlighted in this review and requires addressing to obtain a more stable, sensitive, selective, cost efficient, and real-time glucose sensor.


Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1557
Author(s):  
Farkhod Azimov ◽  
Jihee Kim ◽  
Seong Min Choi ◽  
Hyun Min Jung

α-Fe2O3, which is an attractive material for supercapacitor electrodes, has been studied to address the issue of low capacitance through structural development and complexation to maximize the use of surface pseudocapacitance. In this study, the limited performance of α-Fe2O3 was greatly improved by optimizing the nanotube structure of α-Fe2O3 and its combination with polyaniline (PANI). α-Fe2O3 nanotubes (α-NT) were fabricated in a form in which the thickness and inner diameter of the tube were controlled by Fe(CO)5 vapor deposition using anodized aluminum oxide as a template. PANI was combined with the prepared α-NT in two forms: PANI@α-NT-a enclosed inside and outside with PANI and PANI@α-NT-b containing PANI only on the inside. In contrast to α-NT, which showed a very low specific capacitance, these two composites showed significantly improved capacitances of 185 Fg−1 for PANI@α-NT-a and 62 Fg−1 for PANI@α-NT-b. In the electrochemical impedance spectroscopy analysis, it was observed that the resistance of charge transfer was minimized in PANI@α-NT-a, and the pseudocapacitance on the entire surface of the α-Fe2O3 nanotubes was utilized with high efficiency through binding and conductivity improvements by PANI. PANI@α-NT-a exhibited a capacitance retention of 36% even when the current density was increased 10-fold, and showed excellent stability of 90.1% over 3000 charge–discharge cycles. This approach of incorporating conducting polymers through well-controlled nanostructures suggests a solution to overcome the limitations of α-Fe2O3 electrode materials and improve performance.


Sign in / Sign up

Export Citation Format

Share Document