scholarly journals Real-Time Monitoring of a Botulinum Neurotoxin Using All-Carbon Nanotube-Based Field-Effect Transistor Devices

Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4235 ◽  
Author(s):  
Nam Lee ◽  
Seung-Hoon Nahm ◽  
Insung Choi

The possibility of exposure to botulinum neurotoxin (BoNT), a powerful and potential bioterrorism agent, is considered to be ever increasing. The current gold-standard assay, live-mouse lethality, exhibits high sensitivity but has limitations including long assay times, whereas other assays evince rapidity but lack factors such as real-time monitoring or portability. In this study, we aimed to devise a novel detection system that could detect BoNT at below-nanomolar concentrations in the form of a stretchable biosensor. We used a field-effect transistor with a p-type channel and electrodes, along with a channel comprising aligned carbon nanotube layers to detect the type E light chain of BoNT (BoNT/E-Lc). The detection of BoNT/E-Lc entailed observing the cleavage of a unique peptide and the specific bonding between BoNT/E-Lc and antibody BoNT/E-Lc (Anti-BoNT/E-Lc). The unique peptide was cleaved by 60 pM BoNT/E-Lc; notably, 52 fM BoNT/E-Lc was detected within 1 min in the device with the antibody in the bent state. These results demonstrated that an all-carbon nanotube-based device (all-CNT-based device) could be produced without a complicated fabrication process and could be used as a biosensor with high sensitivity, suggesting its potential development as a wearable BoNT biosensor.

2018 ◽  
Vol 5 (8) ◽  
pp. 1990-1999 ◽  
Author(s):  
Xiaoyan Chen ◽  
Haihui Pu ◽  
Zipeng Fu ◽  
Xiaoyu Sui ◽  
Jingbo Chang ◽  
...  

A benzyltriethylammonium chloride-modified graphene field-effect transistor sensor has high sensitivity, high selectivity and rapid response for nitrate detection.


Nanomaterials ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 2280
Author(s):  
Hong Phan T. Nguyen ◽  
Thanihaichelvan Murugathas ◽  
Natalie O. V. Plank

Carbon nanotube field effect transistor (CNT FET) aptasensors have been investigated for the detection of adenosine using two different aptamer sequences, a 35-mer and a 27-mer. We found limits of detection for adenosine of 100 pM and 320 nM for the 35-mer and 27-mer aptamers, with dissociation constants of 1.2 nM and 160 nM, respectively. Upon analyte recognition the 35-mer adenosine aptamer adopts a compact G-quadruplex structure while the 27-mer adenosine aptamer changes to a folded duplex. Using the CNT FET aptasensor platform adenosine could be detected with high sensitivity over the range of 100 pM to 10 µM, highlighting the suitability of the CNT FET aptasensor platform for high performance adenosine detection. The aptamer restructuring format is critical for high sensitivity with the G-quadraplex aptasensor having a 130-fold smaller dissociation constant than the duplex forming aptasensor.


2021 ◽  
Vol 174 ◽  
pp. 112804
Author(s):  
Seon Joo Park ◽  
Sung Eun Seo ◽  
Kyung Ho Kim ◽  
Sang Hun Lee ◽  
Jinyeong Kim ◽  
...  

2005 ◽  
Vol 1 (1) ◽  
pp. 065-070 ◽  
Author(s):  
Kagan Kerman ◽  
Yasutaka Morita ◽  
Yuzuru Takamura ◽  
Eiichi Tamiya ◽  
Kenzo Maehashi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document