scholarly journals Smartphone-Based Microfluidic Colorimetric Sensor for Gaseous Formaldehyde Determination with High Sensitivity and Selectivity

Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 3141 ◽  
Author(s):  
Xiao-Liang Guo ◽  
Yan Chen ◽  
Hong-Lan Jiang ◽  
Xian-Bo Qiu ◽  
Du-Li Yu

Formaldehyde is one of the most dangerous air pollutants, which can cause sick building syndrome. Thus, it is very crucial to precisely determine formaldehyde with a low cost and simple operation. In this paper, a smartphone-based microfluidic colorimetric sensor is devised for gaseous formaldehyde determination with high sensitivity and selectivity. Specifically, a novel microfluidic chip is proposed based on the 4-aminohydrazine-5-mercapto-1,2,4-triazole (AHMT) method to determine formaldehyde; the chip consists of two reagent reservoirs, one reaction reservoir and a mixing column. In this design to prevent the fluid from flowing out while letting the gas molecule in, a hydrophobic porous poly tetra fluoroethylene (PTFE) membrane is put on the top of the reaction reservoir. Using the microfluidic chip sensor, a smartphone-based formaldehyde determination system is developed, which makes the measuring process automated and simple. As per the experiment results, the limit-of-detection (LOD) of the system is as low as 0.01 ppm, which is much lower than the maximum exposure concentration (0.08 ppm) recommended by the World Health Organization (WHO). Moreover, the sensor is hardly affected by acetaldehyde, volatile organic compounds (VOCs) or acidic-alkaline, which shows great selectivity. Finally, the performance of the proposed sensor is verified by using it for the determination of formaldehyde in a newly decorated house.

Biosensors ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 300
Author(s):  
Li Gao ◽  
Qiuxiang Lv ◽  
Ni Xia ◽  
Yuanwei Lin ◽  
Feng Lin ◽  
...  

Excessive mercury ions (Hg2+) cause great pollution to soil/water and pose a major threat to human health. The high sensitivity and high selectivity in the Hg2+ detection demonstrated herein are significant for the research areas of analytical chemistry, chemical biology, physical chemistry, drug discovery, and clinical diagnosis. In this study, a series of simple, low-cost, and highly sensitive biochips based on a graphene oxide (GO)/DNA hybrid was developed. Hg2+ is detected with high sensitivity and selectivity by GO/DNA hybrid biochips immobilized on glass slides. The performance of the biosensors can be improved by introducing more phosphorothioate sites and complementary bases. The best limit of detection of the biochips is 0.38 nM with selectivity of over 10:1. This sensor was also used for Hg2+ detection in Dendrobium. The results show this biochip is promising for Hg2+ detection.


Sensor Review ◽  
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Mulayam Singh Gaur ◽  
Rajni Yadav ◽  
Mamta Kushwah ◽  
Anna Nikolaevna Berlina

Purpose This information will be useful in the selection of materials and technology for the detection and removal of mercury ions at a low cost and with high sensitivity and selectivity. The purpose of this study is to provide the useful information for selection of materials and technology to detect and remove the mercury ions from water with high sensitivity and selectivity. The purpose of this study is to provide the useful information for selection of materials and technology to detect and remove the mercury ions from water with high sensitivity and selectivity. Design/methodology/approach Different nano- and bio-materials allowed for the development of a variety of biosensors – colorimetric, chemiluminescent, electrochemical, whole-cell and aptasensors – are described. The materials used for their development also make it possible to use them in removing heavy metals, which are toxic contaminants, from environmental water samples. Findings This review focuses on different technologies, tools and materials for mercury (heavy metals) detection and remediation to environmental samples. Originality/value This review gives up-to-date and systemic information on modern nanotechnology methods for heavy metal detection. Different recognition molecules and nanomaterials have been discussed for remediation to water samples. The present review may provide valuable information to researchers regarding novel mercury ions detection sensors and encourage them for further research/development.


Chemosensors ◽  
2020 ◽  
Vol 8 (4) ◽  
pp. 97
Author(s):  
Oyejide Damilola Oyewunmi ◽  
Seyed Hamid Safiabadi-Tali ◽  
Sana Jahanshahi-Anbuhi

A dip-and-read microfluidic paper-based analytical device (µPAD) was developed for the qualitative and quantitative detection of the total hardness of water. To create well-defined hydrophobic barriers on filter paper, a regular office printer and a commercially available permanent marker pen were utilized as a quick and simple technique with easily accessible equipment/materials to fabricate µPAD in new or resource-limited laboratories without sophisticated equipment. After a wettability and barrier efficiency analysis on the permanent marker colors, the blue and green ink markers exhibited favorable hydrophobic properties and were utilized in the fabrication of the developed test devices. The device had five reaction and detection zones modeled after the classification given by the World Health Organization (WHO), so qualitatively it determined whether the water was ‘soft’, ‘moderately hard’, ‘hard’, or ‘very hard’ by changing color from blue to pink in about 3 min. The device was also used to introduce an alternative colorimetric reaction for quantitative analysis of the water hardness without the need for ethylenediaminetetraacetic acid (EDTA) and without compromising the simplicity and low cost of the device. The developed µPAD showed a calculated limit of detection (LOD) of 0.02 mM, which is at least 80% less than those of commercially available test strips and other reported µPADs, and the results of the real-world samples were consistent with those of the standard titration (with EDTA). In addition, the device exhibited stability for 2 months at room and frigid condition (4 °C) and at varying harsh temperatures from 25 to 100 °C. The results demonstrate that the developed paper-based device can be used for rapid, on-site analysis of water with no interferences and no need for a pipette for sample introduction during testing.


Materials ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2577 ◽  
Author(s):  
Yuanying Liang ◽  
Ting Guo ◽  
Lei Zhou ◽  
Andreas Offenhäusser ◽  
Dirk Mayer

The detection of chemical messenger molecules, such as neurotransmitters in nervous systems, demands high sensitivity to measure small variations, selectivity to eliminate interferences from analogues, and compliant devices to be minimally invasive to soft tissue. Here, an organic electrochemical transistor (OECT) embedded in a flexible polyimide substrate is utilized as transducer to realize a highly sensitive dopamine aptasensor. A split aptamer is tethered to a gold gate electrode and the analyte binding can be detected optionally either via an amperometric or a potentiometric transducer principle. The amperometric sensor can detect dopamine with a limit of detection of 1 μM, while the novel flexible OECT-based biosensor exhibits an ultralow detection limit down to the concentration of 0.5 fM, which is lower than all previously reported electrochemical sensors for dopamine detection. The low detection limit can be attributed to the intrinsic amplification properties of OECTs. Furthermore, a significant response to dopamine inputs among interfering analogues hallmarks the selective detection capabilities of this sensor. The high sensitivity and selectivity, as well as the flexible properties of the OECT-based aptasensor, are promising features for their integration in neuronal probes for the in vitro or in vivo detection of neurochemical signals.


The Analyst ◽  
2016 ◽  
Vol 141 (12) ◽  
pp. 3898-3903 ◽  
Author(s):  
Maowei Dou ◽  
Juan Lopez ◽  
Misael Rios ◽  
Oscar Garcia ◽  
Chuan Xiao ◽  
...  

A low-cost b̲a̲ttery-powered s̲pectrophotometric s̲ystem (BASS) was developed for high-sensitivity point-of-care analysis in low-resource settings on a microfluidic chip without relying on external power supplies.


2018 ◽  
Vol 10 (9) ◽  
pp. 1063-1073 ◽  
Author(s):  
Anupam Ghorai ◽  
Jahangir Mondal ◽  
Amit Kumar Manna ◽  
Shubhamoy Chowdhury ◽  
Goutam K. Patra

A simple, low-cost pyrene derivative containing a benzilmonohydrazone moiety has been exploited for the selective detection of Cu2+ by colorimetric, absorption, emission and bio-imaging methods. The sensitivity of the fluorescence based assay is 7.8 nM for Cu2+, which is far below the limit mentioned in the World Health Organization.


Sensors ◽  
2019 ◽  
Vol 19 (10) ◽  
pp. 2373 ◽  
Author(s):  
Imad Abrao Nemeir ◽  
Joseph Saab ◽  
Walid Hleihel ◽  
Abdelhamid Errachid ◽  
Nicole Jafferzic-Renault ◽  
...  

Breast Cancer is one of the world’s most notorious diseases affecting two million women in 2018 worldwide. It is a highly heterogeneous disease, making it difficult to treat. However, its linear progression makes it a candidate for early screening programs, and the earlier its detection the higher the chance of recovery. However, one key hurdle for breast cancer screening is the fact that most screening techniques are expensive, time-consuming, and cumbersome, making them impractical for use in several parts of the world. One current trend in breast cancer detection has pointed to a possible solution, the use of salivary breast cancer biomarkers. Saliva is an attractive medium for diagnosis because it is readily available in large quantities, easy to obtain at low cost, and contains all the biomarkers present in blood, albeit in lower quantities. Affinity sensors are devices that detect molecules through their interactions with biological recognition molecules. Their low cost, high sensitivity, and selectivity, as well as rapid detection time make them an attractive alternative to traditional means of detection. In this review article, we discuss the current status of breast cancer diagnosis, its salivary biomarkers, as well as the current trends in the development of affinity sensors for their detection.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Quang Hieu Tran ◽  
Thanh Tan Nguyen ◽  
Kim Phuong Pham

A selective, sensitive, and rapid method by using ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the determination of histamine in fish and fish sauce was developed. The optimal conditions of liquid chromatographic separation and mass spectroscopy of histamine have also been investigated. The linear ranges of the method were 20.0 ÷ 1000 ng/mL, and the corresponding correlation coefficient was 0.9993. Mean recoveries of the analyte at three spike levels (low, medium, and high) were within the range of 98.5% ÷ 102.5% (n = 7). The limit of detection (LOD) and limit of quantification (LOQ) values were 3.83 and 11.50 ng/mL for the fish sauce sample and 4.71 and 14.12 ng/mL for the fish sample, respectively. The influence of the matrix effect on the accuracy, repeatability, and recovery of the method was negligible. The recommended method was applied to determine the content of this substance in 21 fish sauce samples and 4 kinds of fish samples, which were collected from Ho Chi Minh City, Vietnam, in 2019.


Sign in / Sign up

Export Citation Format

Share Document