scholarly journals All-Solid-State Potentiometric Ion-Sensors Based on Tailored Imprinted Polymers for Pholcodine Determination

Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1192
Author(s):  
Hisham S. M. Abd-Rabboh ◽  
Abd El-Galil E. Amr ◽  
Abdulrahman A. Almehizia ◽  
Ayman H. Kamel

In recent times, the application of the use of ion-selective electrodes has expanded in the field of pharmaceutical analyses due to their distinction from other sensors in their high selectivity and low cost of measurement, in addition to their high measurement sensitivity. Cost-effective, reliable, and robust all-solid-state potentiometric selective electrodes were designed, characterized, and successfully used for pholcodine determination. The design of the sensor device was based on the use of a screen-printed electrode modified with multiwalled carbon nanotubes (MWCNTs) as a solid-contact transducer. Tailored pholcodine (PHO) molecularly imprinted polymers (MIPs) were prepared, characterized, and used as sensory receptors in the presented potentiometric sensing devices. The sensors exhibited a sensitivity of 31.6 ± 0.5 mV/decade (n = 5, R2 = 0.9980) over the linear range of 5.5 × 10−6 M with a detection limit of 2.5 × 10−7 M. Real serum samples in addition to pharmaceutical formulations containing PHO were analyzed, and the results were compared with those obtained by the conventional standard liquid chromatographic approach. The presented analytical device showed an outstanding efficiency for fast, direct, and low-cost assessment of pholcodine levels in different matrices.

1998 ◽  
Vol 52 (5) ◽  
pp. 750-754 ◽  
Author(s):  
A. Neal Watkins ◽  
Brett R. Wenner ◽  
Jeffrey D. Jordan ◽  
Wenying Xu ◽  
James N. Demas ◽  
...  

A novel sensor for quantifying molecular O2 based entirely on solid-state electronics is presented. The sensor is based on the luminescence quenching of tris(4,7-diphenyl-1, 10-phenanthroline)ruthenium(II) ([Ru(dpp)3]2+) by molecular O2. The sensor involves immobilizing the ruthenium complex within a porous sol-gel-processed glass film and casting this film directly onto the surface of a blue quantum-well light-emitting diode (LED). The ruthenium complex is excited by the LED, the [Ru(dpp)3]2+ emission is filtered from the excitation with a low-cost acrylic color filter, and the emission is detected with an inexpensive silicon photodiode. The sensor response to gaseous O2 and dissolved O2 in water is presented. The sensor exhibits fast response times and good reversibility, and detection limits are 0.5%, 0.02%, and 110 ppb, respectively, for O2 in the gaseous (linear Stern–Vobner and multi-site Stern–Volmer analysis) and aqueous phase. This sensor provides a cost-effective alternative to traditional electrochemical-based O2 sensing and also provides a platform for other optically based sensors.


2011 ◽  
Vol 89 (1) ◽  
pp. 77-82 ◽  
Author(s):  
Stacey D. Haskins ◽  
Christina M. Harrison ◽  
David G. Kelly ◽  
Ron D. Weir

The present study considers simple and cost-effective modifications to commercial pressurised solvent extraction cells to extract polychlorinated biphenyls (PCBs) from avian blood and serum. Blood and serum samples of mass 0.2 g were examined. Such masses are consistent with those which may be obtained from many avian species without sacrificing individuals or compromising breeding and (or) migratory success. Extraction vessels are modified by the use of Teflon inserts, which are readily fabricated at low cost. These inserts reduce internal cell volume and surface area. Thus, background contamination is reduced whilst extraction and rinse solvent is used more effectively to afford a small extract volume. Packing of the cell void with sodium sulfate and florisil achieves in situ sample dehydration and lipid removal. When combined with extraction concentration and large volume injection gas chromatography – ion-trap mass spectrometry (LVI-GC–ITMS), the extraction method is capable of polychlorinated biphenyl analysis without post-extraction clean-up. Validation was accomplished using commercial chicken whole blood and serum, and PCB congeners 28, 77, 105, 126, 153, 167, 170, 180, 183, and 194. Surrogate corrected recoveries in the range of 75% to120% for whole blood and 80% to115% for serum were obtained. Detection limits were in the range of 0.01 to 0.22 ng g–1 for whole blood and 0.03 to 0.45 ng g–1 for serum. The relative standard deviations for all congeners investigated were better than 15%.


Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6301
Author(s):  
Hongshen Li ◽  
Hongrui Liu ◽  
Shizhong Li

To fulfill the consumption demand of low-cost fuel ethanol, an advanced process for feedstock fermentation and bioethanol extraction was required. This study proposed a process of combined continuous solid-state distillation and vapor permeation to extract ethanol from fermented sweet sorghum bagasse on the basis of advanced solid-state fermentation technology. Ethanol undergoes only one phase transition separation in the whole process, which drastically reduces energy consumption compared to the repeating phase transitions that occur in conventional bioethanol production. The mass balance and energy consumption of combining processes were simulated overall. A techno-economic evaluation was conducted on the flowsheet. Costs and profit of fuel ethanol produced by one phase transition separation bioethanol-producing technology were comprehensively calculated. The results of the present study show that the proposed process is an energy efficient and cost-effective alternative to conventional bioethanol production.


2019 ◽  
Author(s):  
Zachary Ballard ◽  
Hyou-Arm Joung ◽  
Artem Goncharov ◽  
Jesse Liang ◽  
Karina Nugroho ◽  
...  

ABSTRACTWe present a deep learning-based framework to design and quantify point-of-care sensors. As its proof-of-concept and use-case, we demonstrated a low-cost and rapid paper-based vertical flow assay (VFA) for high sensitivity C-Reactive Protein (hsCRP) testing, a common medical test used for quantifying the degree of inflammation in patients at risk of cardio-vascular disease (CVD). A machine learning-based sensor design framework was developed for two key tasks: (1) to determine an optimal configuration of immunoreaction spots and conditions, spatially-multiplexed on a paper-based sensing membrane, and (2) to accurately infer the target analyte concentration based on the signals of the optimal VFA configuration. Using a custom-designed mobile-phone based VFA reader, a clinical study was performed with 85 human serum samples to characterize the quantification accuracy around the clinically defined cutoffs for CVD risk stratification. Results from blindly-tested VFAs indicate a competitive coefficient of variation of 11.2% with a linearity of R2 = 0.95; in addition to the success in the high-sensitivity CRP range (i.e., 0-10 mg/L), our results further demonstrate a mitigation of the hook-effect at higher CRP concentrations due to the incorporation of antigen capture spots within the multiplexed sensing membrane of the VFA. This paper-based computational VFA that is powered by deep learning could expand access to CVD health screening, and the presented machine learning-enabled sensing framework can be broadly used to design cost-effective and mobile sensors for various point-of-care diagnostics applications.


2022 ◽  
Vol 12 (2) ◽  
pp. 72-75
Author(s):  
Tanzila Rawnuck ◽  
Md Selim Reza ◽  
Mohammad Jahidur Rahman Khan ◽  
Rashida Akter Khanam ◽  
Saif Ullah Munshi

Background: The Loop-mediated isothermal amplification (LAMP) represents a very sensitive, easy to use, and less time consuming diagnostic method. Aims: The aim was to establish a simple, cost-effective, molecular technique. Materials and methods: An analytical study was conducted using two hundred acute serum samples using two different molecular techniques; qPCR and LAMP to standardize a costeffective and less time-consuming technique. Results: The cost of in-house LAMP reagents was one-ninth of the cost of commercial qPCR. Consume cost was 23 times less than qPCR besides, lab setup cost was 92 times less than qPCR. More importantly, LAMP requires 5-6 times less time duration than qPCR. Conclusion: Due to its simple short-time operation with low cost, it would be a prevalent molecular technique globally, particularly in Bangladesh. J Shaheed Suhrawardy Med Coll 2020; 12(2): 72-75


Processes ◽  
2020 ◽  
Vol 8 (8) ◽  
pp. 962
Author(s):  
Wioletta Parys ◽  
Małgorzata Dołowy ◽  
Alina Pyka-Pająk

The purpose of the work was to develop such chromatographic conditions that allowed to separate as many naproxen degradation products as possible. In order to follow this process, thin-layer chromatography (TLC) coupled with densitometry and spectrodensitometry was used. A forced degradation study was performed using an ethanolic solution of naproxen spotted on silica gel plates, existing in the form of an aqueous solution at various pH values, and as solution prepared in saline and in hydrogen peroxide. Degradative effect of UV light on naproxen was watched in the context of naproxen spotted on plates precoated with silica gel and exposed to UV light, and also for its solution treated with UV light. However, the solution of naproxen prepared in water at pH ≈ 2.60 undergoes the largest changes as the results of its exposure to UV light during 10 h. Stressed samples of naproxen were analyzed by using a new and well validated TLC procedure including toluene (TOL)—acetone (ACE)—chloroform (CHL) (2:5:12, v/v/v) as mobile phase A and glacial acetic acid (AcOH)—n-hexane (Hex)—acetone (ACE)-(0.10:10:10, v/v/v) as mobile phase B. As the newly developed TLC-densitometric method can effectively separate the substances about pharmaceutical significance from products of its degradation, which are formed as a result of stress studies, is considered to be a good alternative and important tool in routine quality control and stability testing of naproxen in pharmaceutical formulations. These results indicate that proposed TLC-densitometric method is cost-effective, rapid, specific, accurate, and precise. This TLC procedure is comparable to HPLC and UPLC method in terms of detection the number of degradation products of naproxen. In addition, it realizes the criterion of linearity. A major advantage and novelty of proposed method is its low cost and ability to analyze examined drug and all degradation products simultaneously, including those which can be observed under intensive UV radiation exposure of naproxen solution which are not described by previous HPTLC studies available in the literature.


Author(s):  
Tanwi Singh ◽  
Anshuman Sinha

The major risk associated with low platelet count in pregnancy is the increased risk of bleeding during the childbirth or post that. There is an increased blood supply to the uterus during pregnancy and the surgical procedure requires cutting of major blood vessels. Women with thrombocytopenia are at increased risk of losing excessive blood. The risk is more in case of caesarean delivery as compared to vaginal delivery. Hence based on above findings the present study was planned for Assessment of the Platelet Count in the Pregnant Women in IGIMS, Patna, Bihar. The present study was planned in Department of Pathology, Indira Gandhi Institute of Medical Science, Patna, Bihar, India. The present study was planned from duration of January 2019 to June 2019. In the present study 200 pregnant females samples received for the platelet estimation were enrolled in the present study. Clinically platelet indices can be a useful screening test for early identification of preeclampsia and eclampsia. Also platelet indices can assess the prognosis of this disease in pregnant women and can be used as an effective prognostic marker because it correlates with severity of the disease. Platelet count is a simple, low cost, and rapid routine screening test. Hence the data generated from the present study concludes that platelet count can be used as a simple and cost effective tool to monitor the progression of preeclampsia, thereby preventing complications to develop during the gestational period. Keywords: Platelet Count, Pregnant Women, IGIMS, Patna, Bihar, etc.


2019 ◽  
Vol 2019 (4) ◽  
pp. 7-22
Author(s):  
Georges Bridel ◽  
Zdobyslaw Goraj ◽  
Lukasz Kiszkowiak ◽  
Jean-Georges Brévot ◽  
Jean-Pierre Devaux ◽  
...  

Abstract Advanced jet training still relies on old concepts and solutions that are no longer efficient when considering the current and forthcoming changes in air combat. The cost of those old solutions to develop and maintain combat pilot skills are important, adding even more constraints to the training limitations. The requirement of having a trainer aircraft able to perform also light combat aircraft operational mission is adding unnecessary complexity and cost without any real operational advantages to air combat mission training. Thanks to emerging technologies, the JANUS project will study the feasibility of a brand-new concept of agile manoeuvrable training aircraft and an integrated training system, able to provide a live, virtual and constructive environment. The JANUS concept is based on a lightweight, low-cost, high energy aircraft associated to a ground based Integrated Training System providing simulated and emulated signals, simulated and real opponents, combined with real-time feedback on pilot’s physiological characteristics: traditionally embedded sensors are replaced with emulated signals, simulated opponents are proposed to the pilot, enabling out of sight engagement. JANUS is also providing new cost effective and more realistic solutions for “Red air aircraft” missions, organised in so-called “Aggressor Squadrons”.


Author(s):  
K. Srinivasa Rao ◽  
Keshar N K ◽  
N Jena ◽  
M.E.B Rao ◽  
A K Patnaik

A stability-indicating LC assay method was developed for the quantitative determination of fenofibrate (FFB) in pharmaceutical dosage form in the presence of its degradation products and kinetic determinations were evaluated in acidic, alkaline and peroxide degradation conditions. Chromatographic separation was achieved by use of Zorbax C18 column (250 × 4.0 mm, 5 μm). The mobile phase was established by mixing phosphate buffer (pH adjusted 3 with phosphoric acid) and acetonitrile (30:70 v/v). FFB degraded in acidic, alkaline and hydrogen peroxide conditions, while it was more stable in thermal and photolytic conditions. The described method was linear over a range of 1.0-500 μg/ml for determination of FFB (r= 0.9999). The precision was demonstrated by relative standard deviation (RSD) of intra-day (RSD= 0.56– 0.91) and inter-day studies (RSD= 1.47). The mean recovery was found to be 100.01%. The acid and alkaline degradations of FFB in 1M HCl and 1M NaOH solutions showed an apparent zero-order kinetics with rate constants 0.0736 and 0.0698  min−1 respectively and the peroxide degradation with 5% H2O2 demonstrated an apparent first-order kinetics with rate constant k = 0.0202 per min. The t1/2, t90   values are also determined for all the kinetic studies. The developed method was found to be simple, specific, robust, linear, precise, and accurate for the determination of FFB in pharmaceutical formulations.  


2018 ◽  
Vol 32 (2) ◽  
pp. 103-119
Author(s):  
Colleen M. Boland ◽  
Chris E. Hogan ◽  
Marilyn F. Johnson

SYNOPSIS Mandatory existence disclosure rules require an organization to disclose a policy's existence, but not its content. We examine policy adoption frequencies in the year immediately after the IRS required mandatory existence disclosure by nonprofits of various governance policies. We also examine adoption frequencies in the year of the subsequent change from mandatory existence disclosure to a disclose-and-explain regime that required supplemental disclosures about the content and implementation of conflict of interest policies. Our results suggest that in areas where there is unclear regulatory authority, mandatory existence disclosure is an effective and low cost regulatory device for encouraging the adoption of policies desired by regulators, provided those policies are cost-effective for regulated firms to implement. In addition, we find that disclose-and-explain regulatory regimes provide stronger incentives for policy adoption than do mandatory existence disclosure regimes and also discourage “check the box” behavior. Future research should examine the impact of mandatory existence disclosure rules in the year that the regulation is implemented. Data Availability: Data are available from sources cited in the text.


Sign in / Sign up

Export Citation Format

Share Document