scholarly journals Shear Bond Strength of Veneered Zirconia Repaired Using Various Methods and Adhesive Systems: A Comparative Study

Polymers ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 910
Author(s):  
Syed Rashid Habib ◽  
Salwa Bajunaid ◽  
Abdulrahman Almansour ◽  
Abdulkarim AbuHaimed ◽  
Muqrin Nasser Almuqrin ◽  
...  

The aim of the present study was to investigate the shear bond strength of five different repair methods and adhesive systems for zirconia (Zr) cores layered with feldspathic porcelain. Seventy-five Zr specimens (10 × 10 × 4 mm3) were prepared, sintered, layered with 2 × 10 × 10 mm3 of feldspathic porcelain, and fired. The ceramic was fractured, and the load recorded using a shear-bond test. Specimens were thermocycled and randomly divided into 5 groups (n = 15/group) based on the repair methods. Composite repair blocks with similar dimensions to the layered ceramic (2 × 10 × 10 mm3) were built according to each repair method. Shear bond strength testing of the specimens with composite built up was carried out using a universal testing machine (Instron®5960, Massachusetts, USA). The shear bond strengths of the adhesive interface between repaired composite and the Zr were recorded for all the test groups. The fractured specimens’ surfaces were examined under a scanning electron microscope (Jeol, Musashino, Akishima, Tokyo, Japan) for evaluation of the type of failure and surface characteristics. Shear bond strength of the veneered ceramic bonded to the Zr for all the test groups was non-significant (ANOVA, p = 0.062). Shear bond strength after the repair revealed significant differences (ANOVA, p = 0.002). Group-C (13.79 ± 1.32) and Group-D (9.77 ± 4.77) showed the highest and lowest shear bond strength values, respectively. Paired Sample T-tests showed significantly lower values (p = 0.000) for the repaired (composite) Zr compared to the layered (ceramic) Zr. Multiple comparisons revealed differences (significant) between the shear bond strength of Group-D with Groups A (p = 0.010) and C (p = 0.003, Post Hoc Tukey test). The repair methods tested showed variations in their respective shear bond strengths. Complete ceramic/zirconia repair systems showed better bonding between the repaired composite and Zr core. The mean shear bond strength for the repaired fractured layered Zr showed acceptable outcomes in terms of clinical perspective, but was, however, unpredictable.

2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
Vajihesadat Mortazavi ◽  
Mohammadhosein Fathi ◽  
Ebrahim Ataei ◽  
Niloufar Khodaeian ◽  
Navid Askari

In this laboratory study shear bond strengths of three filled and one unfilled adhesive systems to enamel and dentine were compared. Forty-eight extracted intact noncarious human mandibular molars were randomly assigned to two groups of 24 one for bonding to enamel and the other for bonding to dentine. Buccal and lingual surfaces of each tooth were randomly assigned for application of each one of filled (Prime & Bond NT (PBNT), Optibond Solo Plus (OBSP), and Clearfil SE Bond (CSEB)) and unfilled (Single Bond (SB)) adhesive systems (n=12). A universal resin composite was placed into the translucent plastic cylinders (3 mm in diameter and 2 mm in length) and seated against the enamel and dentine surfaces and polymerized for 40 seconds. Shear bond strength was determined using a universal testing machine, and the results were statistically analyzed using two-way ANOVA, one-way ANOVA,t-test, and Tukey HSD post hoc test with a 5% level of significance.There were no statistically significant differences in bond strength between the adhesive systems in enamel, but CSEB and SB exhibited significantly higher and lower bond strength to dentine, respectively, than the other tested adhesive systems while there were no statistically significant differences between PBNT and OBSP.


2009 ◽  
Vol 79 (3) ◽  
pp. 564-570 ◽  
Author(s):  
Toshiya Endo ◽  
Rieko Ozoe ◽  
Koichi Shinkai ◽  
Makiko Aoyagi ◽  
Hiroomi Kurokawa ◽  
...  

Abstract Objective: To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. Materials and Methods: A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. Results: At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. Conclusions: The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.


2006 ◽  
Vol 17 (1) ◽  
pp. 39-43 ◽  
Author(s):  
Guilherme Carpena Lopes ◽  
Paula C. Cardoso ◽  
Luiz Clovis Cardoso Vieira ◽  
Luiz N. Baratieri ◽  
Karina Rampinelli ◽  
...  

The aim of this study was to assess the shear bond strength of four acetone-based one-bottle adhesive systems to enamel and dentin, and compare to that of an ethanol-based system used as control. Fifty human molars were bisected mesiodistally and the buccal and lingual surfaces were embedded in acrylic resin using PVC cylinders. The buccal surfaces were ground to obtain flat dentin surfaces, while the lingual surfaces were ground to obtain flat enamel surfaces. All specimens were polished up to 600-grit sandpapers and randomly assigned to 5 groups (n=20; 10 dentin specimens and 10 enamel specimens), according to the adhesive system used: One-Step (Bisco); Gluma One Bond (Heraeus Kulzer); Solobond M (Voco); TenureQuik w/F (Den-Mat) and OptiBond Solo Plus (Kerr) (control). Each adhesive system was applied according to the manufacturers' instructions. The respective proprietary hybrid composite was applied in a gelatin capsule (d=4.3mm) and light-cured for 40 s. The specimens were tested in shear strength with an Instron machine at a crosshead speed of 5 mm/min. Bond strengths means were analyzed statistically by one-way ANOVA and Duncan's post-hoc (p£0.05). Shear bond strength means (MPa) (±SD) to enamel and dentin were: Enamel: One-Step=11.3(±4.9); Gluma One Bond=16.3(±10.1); Solobond M=18.9(±4.5); TenureQuik w/F=18.7(±4.5) and OptiBond Solo Plus=16.4(±3.9); Dentin: One-Step=6.4(±2.8); Gluma One Bond=3.0(±3.4); Solobond M=10.6(±4.9); TenureQuik w/F=7.8(±3.9) and OptiBond Solo Plus=15.1(±8.9). In enamel, the adhesive systems had statistically similar bond strengths to each other (p>0.05). However, the ethanol-based system (OptiBond Solo Plus) showed significantly higher bond strength to dentin than the acetone-based systems (p£0.0001). In conclusion, the solvent type (acetone or ethanol) had no influence on enamel bond strength, but had great influence on dentin bonding, which should be taken into account when choosing the adhesive system.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Ahmed Mohammed Hassan ◽  
Ahmed Ali Goda ◽  
Kusai Baroudi

Objective. The aim of this study was to evaluate the effect of different disinfectant agents on bond strength of two types of resin composite materials.Methods. A total of 80 sound posterior teeth were used. They were divided into four groups(n=20)according to the dentin surface pretreatment (no treatment, chlorhexidine gluconate 2%, sodium hypochlorite 4%, and EDTA 19%). Each group was divided into two subgroups according to the type of adhesive (prime and bond 2.1 and Adper easy one). Each subgroup was further divided into two subgroups according to the type of resin composite (TPH spectrum and Tetric EvoCeram). Shear bond strength between dentin and resin composite was measured using Universal Testing Machine. Data collected were statistically analyzed byt-test and one-way ANOVA followed by Tukey’spost hoctest.Results. It was found that dentin treated with EDTA recorded the highest shear bond strength values followed by sodium hypochlorite and then chlorhexidine groups while the control group showed the lowest shear bond strength.Conclusions. The surface treatment of dentin before bonding application has a great effect on shear bond strength between resin composite and dentin surface.


Materials ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2216 ◽  
Author(s):  
Paulo Palma ◽  
Joana Marques ◽  
Rui Falacho ◽  
Alexandra Vinagre ◽  
João Santos ◽  
...  

The purpose of the present study was to assess the proper time to perform a restoration (immediately or delayed) after placement of two calcium silicate-based cements (CSCs) and to test the performance of two different restorative protocols regarding shear bond strength (SBS). Seventy-five acrylic blocks were randomly divided into five groups (n = 15). Specimens were filled with either ProRoot MTA (Dentsply Tulsa Dental) or Biodentine (Septodont). The restoration was performed at an immediate (12 min) or delayed (seven days) timeframe, using a resin-based flowable composite (SDR) (bonded to the CSC using a universal bonding system) or glass ionomer cement (GIC) as restorative materials. SBS was measured using a universal testing machine. Fractured surfaces were evaluated, and the pattern was registered. Statistical analysis was performed using the Dunn–Sidak post hoc test (P < 0.05). Biodentine/immediate SDR showed the highest mean SBS value (4.44 MPa), with statistically significant differences when compared to mineral trioxide aggregate (MTA)/GIC (1.14 MPa) and MTA/immediate SDR (1.33 MPa). MTA/GIC and MTA/immediate SDR did not present significant differences regarding SBS. No statistical differences were verified concerning mean SBS between both CSCs within the 7 day groups. MTA/delayed SDR (3.86 MPa) presented statistical differences compared to MTA/immediate SDR, whereas no differences were observed regarding Biodentine performance (Biodentine/immediate SDR and Biodentine/delayed SDR (3.09 MPa)). Bonding procedures directly on top of MTA might be preferably performed at a delayed timeframe, whereas Biodentine might allow for immediate restoration.


2014 ◽  
Vol 15 (6) ◽  
pp. 688-692 ◽  
Author(s):  
Sukumaran Anil ◽  
Farouk Ahmed Hussein ◽  
Mohammed Ibrahim Hashem ◽  
Elna P Chalisserry

ABSTRACT Objective The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Subjects and methods Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. Results No statistically significant difference was found in bond strengths’ values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. Conclusion The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength. How to cite this article Hussein FA, Hashem MI, Chalisserry EP, Anil S. The Impact of Chlorhexidine Mouth Rinse on the Bond Strength of Polycarbonate Orthodontic Brackets. J Contemp Dent Pract 2014;15(6):688-692.


2019 ◽  
Vol 13 (01) ◽  
pp. 075-081 ◽  
Author(s):  
Tool Sriamporn ◽  
Ploypim Kraisintu ◽  
Lily Pachanin See ◽  
Somporn Swasdison ◽  
Awiruth Klaisiri ◽  
...  

Abstract Objective The aim of this study was to evaluate the effect of neutralizing agents on the shear bond strength of hydrofluoric (HF)–etched porcelain in nonaging and aging conditions. Subjects and Methods One hundred and twenty feldspathic porcelain specimens were prepared and divided into six groups to undergo different surface conditioning methods—group 1: control; group 2: HF; group 3: HF + calcium hydroxide; group 4: HF + calcium carbonate; group 5: HF + calcium gluconate; and group 6: HF + ultrasonic. All samples were immersed in 37°C distilled water for 24 h. Half of the samples were thermocycled in water for 5,000 cycles. The shear bond strength test was performed using a universal testing machine at a crosshead speed of 0.5 mm/min. Data were statistically analyzed by two-way ANOVA and Tukey's multiple comparison test at a 95% confidence level. The surface micromorphology and surface elements were analyzed using scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy (EDX), respectively. Results The shear bond strengths of groups 2–6 were significantly higher than the control group in both aging and nonaging conditions (p < 0.05). There were no significant differences among all of the HF-etched porcelain groups (p > 0.05). SEM images of groups 2–6 illustrated similar patterns of irregularity on the specimen surfaces. Elemental analysis of EDX demonstrated identical elements on surfaces of specimens of groups 2–6. Conclusion Within the limitations of this study, shear bond strength values between HF-etched porcelain, HF-etching followed by application of neutralizing agents, and HF-etching followed by ultrasonic cleaning were not significantly different in both nonaging and aging conditions.


2009 ◽  
Vol 79 (3) ◽  
pp. 571-576 ◽  
Author(s):  
Buncha Samruajbenjakul ◽  
Boonlert Kukiattrakoon

Abstract Objective: To test the hypothesis that the there is no difference between the shear bond strengths of different base designs of ceramic brackets bonded to glazed feldspathic porcelains. Materials and Methods: Forty glazed feldspathic porcelain specimens (15 mm in diameter and 1.5 mm in thickness) were prepared and divided into 4 groups (n = 10). Ten pieces of each group of different ceramic bracket base designs (beads, large round pits, and irregular base) and one group of stainless steel brackets (served as a control) were bonded to glazed feldspathic porcelains under a 200 gram load. Then all samples were subjected to shear bond strength evaluation with a universal testing machine at a crosshead speed of 0.2 mm/min. Data were analyzed through one-way ANOVA and Tukey's HSD test at a .05 significance level. The mode of failure after debonding was examined under a stereoscope. Results: This study revealed that the beads base design had the greatest shear bond strength (24.7 ± 1.9 MPa) and was significantly different from the large round pits base (21.3 ± 2 MPa), irregular base (19.2 ± 2.0 MPa), and metal mesh base (15.2 ± 2.4 MPa). The beads base design had 100% porcelain-adhesive failure, the large round pits had 100% bracket-adhesive failure, and the irregular base design had 70% combination failure and 30% porcelain-adhesive failure. Conclusions: The hypothesis is rejected. The various base designs of metal and ceramic brackets influence bond strength to glazed feldspathic porcelain, but all should be clinically acceptable.


2015 ◽  
Vol 40 (4) ◽  
pp. 372-378 ◽  
Author(s):  
VK Kalavacharla ◽  
NC Lawson ◽  
LC Ramp ◽  
JO Burgess

SUMMARY Objectives To measure the effects of hydrofluoric acid (HF) etching and silane prior to the application of a universal adhesive on the bond strength between lithium disilicate and a resin. Methods and Materials Sixty blocks of lithium disilicate (e.max CAD, Ivoclar Vivadent) were sectioned into coupons and polished. Specimens were divided into six groups (n=10) based on surface pretreatments, as follows: 1) no treatment (control); 2) 5% HF etch for 20 seconds (5HF); 3) 9.5% HF etch for 60 seconds (9.5HF); 4) silane with no HF (S); 5) 5% HF for 20 seconds + silane (5HFS); and 6) 9.5% HF for 60 seconds + silane (9.5HFS). All etching was followed by rinsing, and all silane was applied in one coat for 20 seconds and then dried. The universal adhesive (Scotchbond Universal, 3M ESPE) was applied onto the pretreated ceramic surface, air thinned, and light cured for 10 seconds. A 1.5-mm-diameter plastic tube filled with Z100 composite (3M ESPE) was applied over the bonded ceramic surface and light cured for 20 seconds on all four sides. The specimens were thermocycled for 10,000 cycles (5°C-50°C/15 s dwell time). Specimens were loaded until failure using a universal testing machine at a crosshead speed of 1 mm/min. The peak failure load was used to calculate the shear bond strength. Scanning electron microscopy images were taken of representative e.max specimens from each group. Results A two-way analysis of variance (ANOVA) determined that there were significant differences between HF etching, silane treatment, and the interaction between HF and silane treatment (p&lt;0.01). Silane treatment provided higher shear bond strength regardless of the use or concentration of the HF etchant. Individual one-way ANOVA and Tukey post hoc analyses were performed for each silane group. Shear bond strength values for each etch time were significantly different (p&lt;0.01) and could be divided into significantly different groups based on silane treatment: no silane treatment: 0 HF &lt; 5% HF &lt; 9.5% HF; and RelyX silane treatment: 0 HF &lt; 5% HF and 9.5% HF. Conclusions Both HF and silane treatment significantly improved the bond strength between resin and lithium disilicate when used with a universal adhesive.


2014 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Dewi Puspitasari ◽  
Andi Soufyan ◽  
Ellyza Herda

Composite resin is a widely used aesthetic restoration. The restoration can fail due to secondary caries. Chlorhexidinegluconate 2% is used as a cavity disinfectant to eliminate microorganisms on the prepared cavity and to prevent thesecondary caries. The purpose of this study was to analyze the effect of chlorhexidine gluconate 2% to the bondstrength of composite resin with self etch system adhesive on dentine. Sixteen specimens of buccal dentine of premolarscrown are divided into 2 different groups. Group I: Clearfil SE Bond self-etch primer was applied for 20 seconds,Clearfil SE Bond bonding was applied for 5 seconds and polymerized for 10 seconds. Composite resin was constructedincrementally and polymerized for 20 seconds. Group II: prior to self etch primer application as in group I,chlorhexidine gluconate 2% was applied for 15 seconds. Shear bond strength was tested using Testing machine andanalyzed with unpaired T test. The highest shear bond strength was obtained by applying chlorhexidine gluconate 2%.The study concludes that chlorhexidine gluconate 2% application to dentine did not affect significantly to the bondstrength composite resin using self etch adhesive systems.


Sign in / Sign up

Export Citation Format

Share Document