scholarly journals Evaluation of Efficiency of Polymerization, Surface Roughness, Porosity and Adaptation of Flowable and Sculptable Bulk Fill Composite Resins

Molecules ◽  
2021 ◽  
Vol 26 (17) ◽  
pp. 5202
Author(s):  
Elizabeta Gjorgievska ◽  
Daniel S. Oh ◽  
Daewon Haam ◽  
Dragana Gabric ◽  
Nichola J. Coleman

A new category of commercial bulk fill composite resins (CRs) enables the placement of 4-mm-thick layers as an alternative to the traditional time-consuming incremental technique. The purpose of the present study was to compare the efficiency of the polymerization, adaptation and porosity of two high-viscosity ‘sculptable’ bulk fill CRs (Filtek™ Bulk Fill (3M™ ESPE, St. Paul, MN, USA) and Tetric EvoCeram® Bulk Fill (Ivoclar Vivadent AG, Schwan, Liechtenstein)) and two low-viscosity ‘flowable’ bulk fill CRs (SureFil® SDR™ flow (Dentsply Sirona, Charlotte, NC, USA) and Tetric EvoFlow® Bulk Fill (Ivoclar Vivadent AG, Schaan, Liechtenstein)). Cylindrical samples of the bulk fill CRs (4 mm height × 10 mm diameter) were analyzed by Fourier-transform infrared spectroscopy (FTIR) and atomic force microscopy (AFM). Additionally, occlusal cavities were prepared in twelve extracted human molars and restored with the bulk fill CRs (n = 3 for each CR). The adaptation and porosity of the bulk fill CRs were evaluated by X-ray microcomputed tomography (µCT) with a 3D morphometric analysis, and the adaptation was also analyzed by scanning electron microscopy (SEM) on longitudinal vestibulo-oral sections of the restored teeth. The AFM analysis demonstrated that the surface roughness of the SureFil® SDR™ flow was higher than that of the Tetric EvoFlow® Bulk Fill and that the surface roughness of Filtek™ Bulk Fill was higher than that of Tetric EvoCeram® Bulk Fill. µCT and SEM confirmed that the flowable bulk fill CRs had excellent adaptation to the cavity walls. The 3D morphometric analysis showed the highest and lowest degrees of porosity in Filtek™ Bulk Fill and Tetric EvoFlow® Bulk Fill, respectively. In general, the flowable bulk fill CRs exhibited better adaptation, a higher efficiency of polymerization and lower porosity than the sculptable materials.

2008 ◽  
Vol 14 (5) ◽  
pp. 380-386 ◽  
Author(s):  
Ana Carolina Botta ◽  
Sillas Duarte ◽  
Pedro Iris Paulin Filho ◽  
Simoni Maria Gheno

AbstractRoughness increases significantly after finishing procedures. The aim of this study was to assess by the atomic force microscope (AFM) the effect of finishing instruments on the surface roughness of composite resins. A nanofiller composite resin (Filtek Supreme, 3M–F) and a microhybrid composite resin (Point 4, Kerr–P) were selected. The finishing procedures were done with a 30-blade carbide bur (C) and a 30-μm finishing diamond bur (D). Standardized specimens were produced and divided into six experimental groups (n= 4) according to (1) composite resin, (2) absence of finishing (Mylar matrix–M), and (3) finishing instrument (FM, PM, FC, FD, PC, PD). The mean surface roughness was evaluated by AFM in the contact mode. FM and PM groups were assessed statistically by the Student's T test, and FC, FD, PC, PD groups were submitted to variance analysis (ANOVA), both at 5% significance. The mean surface roughness values, in nanometers, were FM, 23.63 (b); FC, 283.88 (c); FD, 510.55 (d); PM, 12.52 (a); PC, 343.98 (c); PD, 531.64 (d). Microhybrid composite displayed less roughness than nanofiller composite in the absence of finishing procedures. The 30-blade carbide bur produced less roughness compared to the extra fine diamond bur.


Polymers ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 586 ◽  
Author(s):  
Saravana Jaganathan ◽  
Mohan Mani ◽  
Ahmad Khudzari

The ultimate goal in tissue engineering is to fabricate a scaffold which could mimic the native tissue structure. In this work, the physicochemical and biocompatibility properties of electrospun composites based on polyurethane (PU) with added pepper mint (PM) oil and copper sulphate (CuSO4) were investigated. Field Emission Electron microscope (FESEM) study depicted the increase in mean fiber diameter for PU/PM and decrease in fiber diameter for PU/PM/CuSO4 compared to the pristine PU. Fourier transform infrared spectroscopy (FTIR) analysis revealed the formation of a hydrogen bond for the fabricated composites as identified by an alteration in PU peak intensity. Contact angle analysis presented the hydrophobic nature of pristine PU and PU/PM while the PU/PM/CuSO4 showed hydrophilic behavior. Atomic force microscopy (AFM) analysis revealed the increase in the surface roughness for the PU/PM while PU/PM/CuSO4 showed a decrease in surface roughness compared to the pristine PU. Blood compatibility studies showed improved blood clotting time and less toxic behavior for the developed composites than the pristine PU. Finally, the cell viability of the fabricated composite was higher than the pristine PU as indicated in the MTS assay. Hence, the fabricated wound dressing composite based on PU with added PM and CuSO4 rendered a better physicochemical and biocompatible nature, making it suitable for wound healing applications.


2019 ◽  
Vol 8 (4) ◽  
Author(s):  
Frederico dos Reis Goyatá ◽  
Sávio Morato de Lacerda Gontijo ◽  
José Alcides Almeida de Arruda ◽  
João Batista Novaes Júnior ◽  
Ivan Doche Barreiros ◽  
...  

The aim of the present report was to describe a case of direct composite resin restoration in tooth 46, with emphasis on the importance of polishing. A 21-year-old female patient dissatisfied with the aesthetic amalgam restoration of her tooth 46 came to the our institution for correction of the situation. The procedure performed consisted of registration of occlusal contacts, selection of resin color, removal of amalgam restoration, coronal reconstruction with composite resin, occlusal adjustment, finishing and polishing, with the use of atomic force microscopy of the resin before and after polishing. A correct clinical protocol for the posterior composite resins is fundamental for the optimization of aesthetic results, for clinical performance and for consequent restorative longevity. The atomic force microscopy images of the resin used before and after polishing emphasize the necessity and clinical importance of this operative step.Descriptors: Dental Materials; Dental Restoration, Permanent; Dental Polishing; Microscopy.ReferencesFrese C, Staehle HJ, Wolff D. The assessment of dentofacial esthetics in restorative dentistry: a review of the literature. J Am Dent Assoc. 2012;143(5):461-66.Moraschini V, Fai CK, Alto RM, dos Santos GO. Amalgam and resin composite longevity of posterior restorations: A systematic review and meta-analysis. J Dent. 2015;43(9):1043-50.Kovarik RE. Restoration of posterior teeth in clinical practice: evidence base for choosing amalgam versus composite. Dent Clin North Am. 2009;53(1):71-6.Kanzow P, Wiegand A, Schwendicke F. Cost-effectiveness of repairing versus replacing composite or amalgam restorations. J Dent. 2016;54:41-7.Lynch CD, Opdam NJ, Hickel R, Brunton PA, Gurgan S, Kakaboura A, et al. Guidance on posterior resin composites: Academy of Operative Dentistry - European Section. J Dent. 2014;42(4):377-83.Fernández E, Martín J, Vildósola P, Oliveira Junior OB, Gordan V, Mjor I et al. Can repair increase the longevity of composite resins? Results of a 10-year clinical trial. J Dent. 2015;43(2):279-86.Sabbagh J, McConnell RJ, McConnell MC. Posterior composites: Update on cavities and filling techniques. J Dent. 2017;57:86-90.Constantinescu DM, Apostol DA, Picu CR, Krawczyk K, Sieberer M. Mechanical properties of epoxy nanocomposites reinforced with functionalized silica nanoparticles. Proc Struct Integ. 2017;5:647-52.Yadav RD, Raisingani D, Jindal D, Mathur R. A comparative analysis of different finishing and polishing devices on nanofilled, microfilled, and hybrid composite: a scanning electron microscopy and profilometric study. Int J Clin Pediatr Dent. 2016;9(3):201-8.Fernandes ACBCJ, Assunção IV, Borges BCD, Costa GFA. Impact of additional polishing on the roughness and surface morphology of dental composite resins. Rev Port Estomatol Med Dent Cirur Maxilofac. 2016;57(2):74-81.Antonson SA, Yazici AR, Kilinc E, Antonson DE, Hardigan PC. Comparison of different finishing/polishing systems on surface roughness and gloss of resin composites. J Dent. 2011;39(Suppl 1):e9-17.Kumari CM, Bhat KM, Bansal R. Evaluation of surface roughness of different restorative composites after polishing using atomic force microscopy. J Conserv Dent. 2016;19(1):56-62.Pimentel PEZ, Goyatá FR, Cunha LG. Influência da técnica de polimento na lisura superficial de resinas compostas. Clin int j braz dent. 2012;8(2):226-34.Chour RG, Moda A, Arora A, Arafath MY, Shetty VK, Rishal Y. Comparative evaluation of effect of different polishing systems on surface roughness of composite resin: An in vitro study. J Int Soc Prev Community Dent. 2016;6(Suppl 2):166-70.Lins FC, Ferreira RC, Silveira RR, Pereira CN, Moreira AN, Magalhaes CS. Surface roughness, microhardness, and microleakage of a silorane-based composite resin after immediate or delayed finishing/polishing. Int J Dent. 2016;2016:8346782.


2020 ◽  
Vol 33 (2) ◽  
pp. 59-68
Author(s):  
Bruna Tavares ◽  
Fabiana França ◽  
Roberta Basting ◽  
Basting Turssi ◽  
Turssi Amaral

The aim of this in vitro study was to evaluate the effect of bleaching protocols on the surface roughness (Ra), color change and surface micromorphology of a low-viscosity bulk-fill composite (Filtek Bulk Fill Flow, 3M ESPE), a highviscosity bulk-fill composite (Filtek Bulk Fill, 3M ESPE) and a conventional nanoparticulate composite resin (control) (Filtek Z350 XT, 3M ESPE). Forty samples of each composite (disks 5 mm in diameter and 2 mm thick) were randomly divided into four groups (n=10), according to bleaching protocol: a) 10% carbamide peroxide gel (Opalescence, Ultradent Products) (2 h/ day, for 14 days); b) 40% hydrogen peroxide gel (Opalescence Boost, Ultradent Products) (three bleaching sessions, once a week, 45 min/session); c) whitening rinse (Listerine Whitening Extreme, Johnson & Johnson) (2 min/day, for 14 days); and d) distilled water (control). The samples were submitted to triplicate readings (Ra and color [CIELAB parameters]) before and after contact with bleaching protocols. Micromorphology was analyzed in a scanning electron microscope (SEM). Ra and color parameters (ΔL, Δa, Δb and ΔE) were analyzed by generalized linear models (α=0.05). The Ra of the high-viscosity bulk-fill was significantly higher than that of the other composites (p<0.05). Ra increased significantly (p<0.05) and surface became more irregular (SEM analysis) in all the composite resins, regardless of the bleaching protocol (p<0.05). The high-viscosity bulk-fill composite resin group had significantly lower ΔE (p<0.05) than the nanoparticulate composite resin group immersed in distilled water. It was concluded that the characteristics of each resin significantly influenced the Ra more than the bleaching protocol. The high-viscosity bulk-fill resin presented minor color change.


2016 ◽  
Vol 19 (3) ◽  
pp. 65
Author(s):  
Rafaela Yoshie Oliveira Kinoshita ◽  
Ricardo Sgura ◽  
Mariana Cavalcante Reis ◽  
Milton Satoiuqui Masuda ◽  
Paulo Sérgio Lopes Prazeres ◽  
...  

<p><strong>Objective</strong>: the aim of this study was to assess the effects of whitening dentifrices on the surface roughness of three commercial nanofiller-based composite. <strong>Material and Methods</strong>: two optical analyses were performed: stereomicroscopy and atomic force microscopy (AFM). Disks (8.0 diam. x 2.0 mm thick.) of the nanocomposite Z350 (3M ESPE) and two nano-hybrid composites (EsthetXHD, Dentsply and Premisa, Kerr) were submitted to <em>in vitro</em> brushing (1000 cycles) with three whitening dentifrices (Colgate Luminous White, Oral-B 3D White e Close-Up Diamond Attraction) and a control (Colgate Total12). The results were analyzed by stereomicroscopy and rated according to the following criteria: 0 – no observed roughness, 1 – average roughness, 2 – great roughness. Data was submitted to Kruskall-Wallis non-parametric test followed by Tukey test (p = 0.05). Z350 specimens were assessed by AFM. <strong>Results</strong>: the surface roughness of composites brushed with whitening dentifrices was statistically higher than the roughness found in specimens brushed with conventional dentifrice. AFM analyses showed that, at a submicrometric scale, there was an increase in the number of peaks and irregularities in specimens brushed with whitening dentifrices. <strong>Conclusion</strong>: Whitening dentifrices may have an impact on the longevity of dental composites by an increase in its roughness. It is strongly recommended that clinicians guide their patients, warning them about the risks and consequences of their use.</p><p> </p><p><strong>Keywords</strong></p><p>Abrasion; Dentifrices; Composites resin; Roughness; Whitening; Abrasive.</p>


Author(s):  
H. Kinney ◽  
M.L. Occelli ◽  
S.A.C. Gould

For this study we have used a contact mode atomic force microscope (AFM) to study to topography of fluidized cracking catalysts (FCC), before and after contamination with 5% vanadium. We selected the AFM because of its ability to well characterize the surface roughness of materials down to the atomic level. It is believed that the cracking in the FCCs occurs mainly on the catalysts top 10-15 μm suggesting that the surface corrugation could play a key role in the FCCs microactivity properties. To test this hypothesis, we chose vanadium as a contaminate because this metal is capable of irreversibly destroying the FCC crystallinity as well as it microporous structure. In addition, we wanted to examine the extent to which steaming affects the vanadium contaminated FCC. Using the AFM, we measured the surface roughness of FCCs, before and after contamination and after steaming.We obtained our FCC (GRZ-1) from Davison. The FCC is generated so that it contains and estimated 35% rare earth exchaged zeolite Y, 50% kaolin and 15% binder.


2020 ◽  
Author(s):  
Benjamin P. A. Gabriele ◽  
Craig J. Williams ◽  
Douglas Stauffer ◽  
Brian Derby ◽  
Aurora J. Cruz-Cabeza

<div> <div> <div> <p>Single crystals of aspirin form I were cleaved and indented on their dominant face. Upon inspection, it was possible to observe strongly anisotropic shallow lateral cracks due to the extreme low surface roughness after cleavage. Atomic Force Microscopy (AFM) imaging showed spalling fractures nucleating from the indent corners, forming terraces with a height of one or two interplanar spacings d100. The formation of such spalling fractures in aspirin was rationalised using basic calculations of attachment energies, showing how (100) layers are poorly bonded when compared to their relatively higher intralayer bonding. An attempt at explaining the preferential propagation of these fractures along the [010] direction is discussed. </p> </div> </div> </div>


2020 ◽  
Author(s):  
Benjamin P. A. Gabriele ◽  
Craig J. Williams ◽  
Douglas Stauffer ◽  
Brian Derby ◽  
Aurora J. Cruz-Cabeza

<div> <div> <div> <p>Single crystals of aspirin form I were cleaved and indented on their dominant face. Upon inspection, it was possible to observe strongly anisotropic shallow lateral cracks due to the extreme low surface roughness after cleavage. Atomic Force Microscopy (AFM) imaging showed spalling fractures nucleating from the indent corners, forming terraces with a height of one or two interplanar spacings d100. The formation of such spalling fractures in aspirin was rationalised using basic calculations of attachment energies, showing how (100) layers are poorly bonded when compared to their relatively higher intralayer bonding. An attempt at explaining the preferential propagation of these fractures along the [010] direction is discussed. </p> </div> </div> </div>


Molecules ◽  
2021 ◽  
Vol 26 (4) ◽  
pp. 900
Author(s):  
Maria Vardaki ◽  
Aida Pantazi ◽  
Ioana Demetrescu ◽  
Marius Enachescu

In this work we present the results of a functional properties assessment via Atomic Force Microscopy (AFM)-based surface morphology, surface roughness, nano-scratch tests and adhesion force maps of TiZr-based nanotubular structures. The nanostructures have been electrochemically prepared in a glycerin + 15 vol.% H2O + 0.2 M NH4F electrolyte. The AFM topography images confirmed the successful preparation of the nanotubular coatings. The Root Mean Square (RMS) and average (Ra) roughness parameters increased after anodizing, while the mean adhesion force value decreased. The prepared nanocoatings exhibited a smaller mean scratch hardness value compared to the un-coated TiZr. However, the mean hardness (H) values of the coatings highlight their potential in having reliable mechanical resistances, which along with the significant increase of the surface roughness parameters, which could help in improving the osseointegration, and also with the important decrease of the mean adhesion force, which could lead to a reduction in bacterial adhesion, are providing the nanostructures with a great potential to be used as a better alternative for Ti implants in dentistry.


Sign in / Sign up

Export Citation Format

Share Document