scholarly journals The In Vitro Effects of Pentamidine Isethionate on Coagulation and Fibrinolysis

Molecules ◽  
2019 ◽  
Vol 24 (11) ◽  
pp. 2146 ◽  
Author(s):  
Rami A. Al-Horani ◽  
Daytriona Clemons ◽  
Madhusoodanan Mottamal

Pentamidine is bis-oxybenzamidine-based antiprotozoal drug. The parenteral use of pentamidine appears to affect the processes of blood coagulation and/or fibrinolysis resulting in rare but potentially life-threatening blood clot formation. Pentamidine was also found to cause disseminated intravascular coagulation syndrome. To investigate the potential underlying molecular mechanism(s) of pentamidine’s effects on coagulation and fibrinolysis, we studied its effects on clotting times in normal and deficient human plasmas. Using normal plasma, pentamidine isethionate doubled the activated partial thromboplastin time at 27.5 µM, doubled the prothrombin time at 45.7 µM, and weakly doubled the thrombin time at 158.17 µM. Using plasmas deficient of factors VIIa, IXa, XIa, or XIIa, the concentrations to double the activated partial thromboplastin time were similar to that obtained using normal plasma. Pentamidine also inhibited plasmin-mediated clot lysis with half-maximal inhibitory concentration (IC50) value of ~3.6 μM. Chromogenic substrate hydrolysis assays indicated that pentamidine inhibits factor Xa and plasmin with IC50 values of 10.4 µM and 8.4 µM, respectively. Interestingly, it did not significantly inhibit thrombin, factor XIa, factor XIIIa, neutrophil elastase, or chymotrypsin at the highest concentrations tested. Michaelis-Menten kinetics and molecular modeling studies revealed that pentamidine inhibits factor Xa and plasmin in a competitive fashion. Overall, this study provides quantitative mechanistic insights into the in vitro effects of pentamidine isethionate on coagulation and fibrinolysis via the disruption of the proteolytic activity of factor Xa and plasmin.

2020 ◽  
Vol 42 (3) ◽  
Author(s):  
Erica Scalambrino ◽  
Lidia Padovan ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Andrea Artoni ◽  
...  

1975 ◽  
Author(s):  
A. Teien ◽  
M. Lie

Heparin was added in vitro to plasma and the heparin content assayed by five clotting methods. The accuracy was lower in pathological than in normal plasma. At a heparin concentration of 0.5 U/ml plasma the coefficient of variation in eleven pathological plasmas was: Polybrene titration 3 per cent, method of Denson and Bonnar 15 per cent, method of Yin et al. 20 per cent, calcium thrombin time 40 per cent. With the APTT method the results ranged from 0.05 U/ml to above 0.6 U/ml (no clotting in five pathological plasmas).At a heparin concentration of 0.05 U/ml plasma, only the calcium thrombin time and the factor Xa methods were sensitive, but the coefficient of variation ranged from 61 to 78 per cent. The influence of the concentration of fibrinogen, antithrombin III and α1-acid glucoprotein was studied. It is concluded that of the methods tested, only polybrene titration gives accurate results in pathological plasmas. This method is, however, laborious and insensitive to heparin concentrations below 0.1 U/ml.


Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 2275-2275
Author(s):  
Jonathan Douxfils ◽  
François Mullier ◽  
Christian Chatelain ◽  
Bernard Chatelain ◽  
Dogné Jean-Michel

Abstract Abstract 2275 Introduction: Apixaban is direct factor-Xa inhibitor that reached the market for the prevention of venous thromboembolism in patients undergoing major orthopaedic surgery. It is also being evaluated in the reduction of recurrent ischemic events when added to antiplatelet therapy after an acute coronary syndrome and in the prevention of stroke in patients with non-valvular atrial fibrillation. Thanks to its predictable pharmacokinetic profile, biological monitoring is not required. Nevertheless, evaluation of plasma drug concentration may be valuable in specific situations such as recurrent thrombosis, bleedings, before urgent surgery, in case of bridging and in case of at least two risk factors among the following ones: drug interactions with caution, moderate renal impairment and moderate hepatic impairment; Monitoring may also be useful in infants, pregnant women or in extreme body weights, although no relevant data on drug levels associated with approximate therapeutic and harmful ranges are currently available. Material and Methods: Apixaban was spiked at increasing concentrations (0, 5, 10, 20, 50, 100, 200 and 500 ng/mL) in pooled citrated normal human platelet poor plasma (PPP) to measure Prothrombin Time (PT) and dilute PT with different thromboplastin, Thrombin Generation Assay (TGA) with different inducers and activity on different anti-Xa chromogenic assays. Activated Partial Thromboplastin Time with different reagents, Thrombin Time (TT), Ecarin Clotting Time (ECT) and Reptilase Time (RT), measurement of fibrinogen (Clauss method and PT-derived method) and antithrombin (anti-IIa and anti-Xa based chromogenic assays) were also tested. We also evaluated the impact of apixaban on assays used for the determination of lupus anticoagulant such as the DRVV-T.. (Screen and Confirm) as well as the PTT-LA.. and the Staclot-LA.. . Results and Discussion: As mentioned in previous studies, PT showed a weak sensitivity towards apixaban in comparison with the plasma range obtained in short pharmacokinetic studies. Indeed, the concentration needed to double the clotting time was 154 ng/mL with the most sensitive reagent while the mean Cmax obtained in a short PK study after one oral intake of 5 mg apixaban (dose given in atrial fibrillation) was 96 ng/mL. Therefore, the sensitivity of PT is not strong enough to allow accurate quantitative measurement of the plasma drug concentration (Table 1). Activated Partial Thromboplastin Time presented a better sensitivity but showed a plateau after 100 ng/mL reflecting the uselessness of this test for the quantification of apixaban. Thrombin Time, ECT and RT were logically not affected while DRVV-T.. showed a sensitivity of 205 ng/mL (Screen), which is once again not enough sensitive. On the opposite, chromogenic anti-Xa assays seemed to be very sensitive (Figure 2 and Table 1). Nevertheless, the relation was not always linear and some methodologies needed to be adapted to ensure a broader range of application. TGA (Figure 1) may be useful to assess the pharmacodynamics effects of apixaban on the coagulation process. Nevertheless, the turn around time and the lack of standardisation are currently limitations that restrict the use of this method. In the case of the exploration of an haemorrhagic event, specific tests such as RT, fibrinogen (Clauss and PT-derived method (dFib)), TT and clotting factor activity may be used. Apixaban did not interfere with these tests. Antithrombin determination if also of importance and chromogenic anti-IIa based assays should be used in face of patients treated with apixaban to avoid misdiagnosis since an overvaluation of 12% by 100 ng/mL was shown using one chromogenic anti-Xa based assay. Conclusion: PT may not be used as screening test to assess the risk of bleedings. A more specific and sensitive assay such as chromogenic anti-Xa assays using calibrators should be used to correctly assess the concentration of apixaban. Determination of lupus anticoagulant using DRVV-T.. and PTT-LA.. or Staclot LA.. as well as the determination of antithrombin using factor-Xa based chromogenic assays, were influenced by apixaban. Finally, standardization of the time between the last intake of apixaban and the sampling is mandatory. Figures: Disclosures: No relevant conflicts of interest to declare.


2006 ◽  
Vol 130 (11) ◽  
pp. 1605-1611 ◽  
Author(s):  
Agata Smogorzewska ◽  
John T. Brandt ◽  
Wayne L. Chandler ◽  
Mark T. Cunningham ◽  
Timothy E. Hayes ◽  
...  

Abstract Context.—Fondaparinux, a factor Xa inhibitor, is approved for thromboprophylaxis after orthopedic surgery and for treatment of venous thromboembolism. It may also be efficacious, safe, and cost-effective for other patients; thus, more widespread use of fondaparinux is likely. The effect of fondaparinux on coagulation testing needs to be thoroughly examined. Objective.—To report the effects of fondaparinux on coagulation tests (prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, factor VIII, thrombin time, anti–factor Xa) across diverse methodologies. Design.—Samples with different concentrations of fondaparinux (0, 0.4, 0.8, and 2.0 μg/mL) were sent to laboratories participating in the College of American Pathologists Comprehensive Coagulation proficiency survey (N = 898). Laboratory-specific methods were used to assay coagulation parameters. Results.—Prophylactic or therapeutic fondaparinux prolonged the prothrombin time by approximately 1 second and the activated partial thromboplastin time by 4 to 5 seconds, and reduced factor VIII from 119% to 107% and 102%, respectively. Supratherapeutic fondaparinux reduced factor VIII to 85%. The activated partial thromboplastin time was prolonged in 19%, 29%, and 52% of laboratories with prophylactic, therapeutic, and supratherapeutic fondaparinux levels, respectively. Fibrinogen, antithrombin, and thrombin time assays did not show clinically significant changes. When measuring fondaparinux concentration using an anti–factor Xa assay, the most accurate results were obtained when fondaparinux was used as the calibrator. Conclusions.—Fondaparinux, even in prophylactic doses, slightly prolongs the prothrombin time and activated partial thromboplastin time and can interfere with factor VIII assays, but it has no clinically relevant effect on fibrinogen, antithrombin, or thrombin time. A fondaparinux standard curve should be used for reporting fondaparinux levels using an anti–factor Xa assay.


e-Polymers ◽  
2003 ◽  
Vol 3 (1) ◽  
Author(s):  
Dilyana Paneva ◽  
Olya Stoilova ◽  
Nevena Manolova ◽  
Dobri Danchev ◽  
Zdravko Lazarov ◽  
...  

Abstract Copolymers of 2-acryloylamido-2-methylpropanesulfonic acid (AMPS) and acrylic acid (AA), as well as the corresponding homopolymers PAMPS and PAA, were studied in vitro on human pool plasma for their anticoagulant activity. The values of the haemostatic parameters - prothrombin time, activated partial thromboplastin time and thrombin time - depend on the composition and the concentration of the (co)polymers. Reptilase time remains unchanged on adding the (co)polymers. A broad concentration range from 16 μg/ml to 3 mg/ml was studied. The copolymers possess anticoagulant activity, which is higher at higher content of AMPS units. It was found that, at certain concentrations, the haemostatic parameters of PAMPS are close to that of heparin. PAA has the lowest anticoagulant activity.


1979 ◽  
Author(s):  
P. R. Foster ◽  
M. R. Patterson ◽  
A. J. Johnson ◽  
S. M. Middleton

Polyethylene glycol(PEG) precipitation has beer used for the removal of hepatitis B surface antigen (HBsAg) from a concentrate of factors II, IX & X of intermediate purity. HBsAg is precipitated into a fraction PI at 20% (w/v) PEG and pH 6.5 while factors II, IX & X remaining in the supernatant are subsequently precipitated at 30% (w/v) PEG and pH. 5.2These various fractions have been assessed for the presence of potentially thrombogenic materials by in vitro tests. In comparison with the starting material the precipitate rich In factors II, IX & X has a significantly increased non-activated partial thromboplastin time (NAPTT) and a decreased rate of factor Xa generation. By contrast the waste fraction (PI) exhibits a significantly decreased NAPTT and an increased rate of factor Xa generation suggesting that potentially thrombogenic material has been selectively precipitated. This procedure has been used to prepare a factor II, IX & X concentrate containing 100 U FIX/ml with reduced contamination by both HBsAg and thrombogenic materials.


1990 ◽  
Vol 64 (03) ◽  
pp. 402-406 ◽  
Author(s):  
M D Oethinger ◽  
E Seifried

SummaryThe present in vitro study investigated dose-, time- and temperature-dependent effects of two-chain urokinase plasminogen activato(u-PA, urokinase) on normal citrated plasma. When 10 μg/ml u-PA wereadded to pooled normal plasma and incubated for 30 min at an ambient temperature (25° C), α2-antiplas-min decreased to 8% of the control value. Incubation on ice yielded a decrease to 45% of control,whereas α2-antiplasmin was fully consumed at 37° C. Fibrinogen and plasminogen fell to 46% and 39%, respectively, after a 30 min incubation at 25° C. Thrombin time prolonged to 190% of control.Various inhibitors were studied with respect to their suitability and efficacy to prevent these in vitro effects. Aprotinin exhibited a good protective effect on fibrinogen at concentrations exceeding 500 KlU/ml plasma. Its use, however, was limited due to interferences with some haemostatic assays. We could demonstrate that L-Glutamyl-L-Glycyl-L-Arginyl chloromethyl ketone (GGACK) and a specific polyclonal anti-u-PA-antibody (anti-u-PA-IgG) effectively inhibited urokinase-induced plasmin generation without interfering with haemostatic assays. The anti-u-PA-antibody afforded full protection ofα2-antiplasmin at therapeutic levels of u-PA.It is concluded that u-PA in plasma samples from patients during thrombolytic therapy may induce in vitro effects which should be prevented by the use of a suitable inhibitor such as GGACK or specific anti-u-PA-antibody.


1990 ◽  
Vol 63 (01) ◽  
pp. 016-023 ◽  
Author(s):  
A M H P van den Bessekaar ◽  
J Meeuwisse-Braun ◽  
R M Bertina

SummaryFive different APTT reagents, two amidolytic anti-ITa assays, one amidoiytic anti-Xa assay, and one coagulometric anti-Xa/ anti-IIa assay were used to assess the effect of heparin in patients treated for venous thromboembolic disease. Good correlations were observed between lug-transformed APYE> determined with the various reagents (correlation coefficients: 0.92-0.96).Nevertheless there were important differences in the slopes of the lines of relationship between the APTT reagents.Good correlations were observed between the anti-Xa and anti-IIa assay results (correlation coefficients: 0.92-0.97). However, the amidolytic anti-Xa activity was significantly higher (p <0.001) than the two amidolytic anti-IIa activities. Less good correlations were observed between the log-transformed APTTs and the anti-Xa or anti-IIa activities (correlation coefficients: 0.64-0.78). The correlations were improved by transforming the APTT into APTT-ratio, i.e. the ratio of the patient’s APTT to the same patient’s APTT after removal of heparin from the plasma sample by means of ECTEOLA-cellulose treatment. The correlation coefficients of log (AFTT-ratio) with anti-Xa or anti-IIa ranged from 0.76 to 0.87.For both APTT and amidolytic heparin assay, the response to in vitro heparin was different from the response to ex vivo heparin.Therefore, equivalent therapeutic ranges should be assessed by using ex vivo samples rather than in vitro heparin. Because of the response differences between the APTT reagents, it is not adequate to define a therapeutic range for heparin therapy without specification of the reagent.


1994 ◽  
Vol 72 (05) ◽  
pp. 685-692 ◽  
Author(s):  
Michael T Nurmohamed ◽  
René J Berckmans ◽  
Willy M Morriën-Salomons ◽  
Fenny Berends ◽  
Daan W Hommes ◽  
...  

SummaryBackground. Recombinant hirudin (RH) is a new anticoagulant for prophylaxis and treatment of venous and arterial thrombosis. To which extent the activated partial thromboplastin time (APTT) is suitable for monitoring of RH has not been properly evaluated. Recently, a capillary whole blood device was developed for bed-side monitoring of the APTT and it was demonstrated that this device was suitable to monitor heparin therapy. However, monitoring of RH was not evaluated.Study Objectives. To evaluate in vitro and ex vivo the responsiveness and reproducibility for hirudin monitoring of the whole blood monitor and of plasma APTT assays, which were performed with several reagents and two conventional coagulometers.Results. Large interindividual differences in hirudin responsiveness were noted in both the in vitro and the ex vivo experiments. The relationship between the APTT, expressed as clotting time or ratio of initial and prolonged APTT, and the hirudin concentration was nonlinear. A 1.5-fold increase of the clotting times was obtained at 150-200 ng/ml plasma. However, only a 2-fold increase was obtained at hirudin levels varying from 300 ng to more than 750 ng RH/ml plasma regardless of the assays. The relationship linearized upon logarithmic conversion of the ratio and the hirudin concentration. Disregarding the interindividual differences, and presuming full linearity of the relationship, all combinations were equally responsive to hirudin.Conclusions. All assays were equally responsive to hirudin. Levels up to 300 ng/ml plasma can be reliably estimated with each assay. The manual device may be preferable in situations where rapid availability of test results is necessary.


Sign in / Sign up

Export Citation Format

Share Document