scholarly journals Multi-Layer Application of Self-Etch and Universal Adhesives and the Effect on Dentin Bond Strength

Molecules ◽  
2019 ◽  
Vol 24 (2) ◽  
pp. 345 ◽  
Author(s):  
Anna Zecin-Deren ◽  
Jerzy Sokolowski ◽  
Agata Szczesio-Wlodarczyk ◽  
Ireneusz Piwonski ◽  
Monika Lukomska-Szymanska ◽  
...  

Contemporary self-etch and multi-mode adhesives were introduced to ensure a fast and reliable bonding procedure. Yet, in terms of bond strength and stability they failed to perform as well as two-bottle, etch-and-rinse adhesives, which remain the gold standard in terms of durability. The purpose of this study was to assess the shear bond strength (SBS) of dental adhesives to dentin with different application protocols. Two self-etch (Adper Easy One and Xeno V) and two multi-mode adhesives (Single Bond Universal and Prime&Bond One Select) were used in the study. The highest SBS was obtained for Single Bond Universal applied in three layers, while the lowest, for Xeno V applied in one layer. Other tested adhesives obtained the highest SBS when applied in three layers. For all tested adhesives, multi-layer application resulted in an increase in adhesive layer thickness, as observed in SEM. The increased thickness of the adhesive layer produced by triple application of unfilled adhesives corresponded with higher SBS values. The present study showed that using triple adhesive layers with simplified adhesive systems can be recommended to improve their performance. Due to differences in the composition of self-etch and universal adhesives, the exact application protocol is product dependent.

2019 ◽  
Vol 10 (1) ◽  
pp. 124 ◽  
Author(s):  
Anna Zecin-Deren ◽  
Monika Lukomska-Szymanska ◽  
Agata Szczesio-Wlodarczyk ◽  
Ireneusz Piwonski ◽  
Jerzy Sokolowski ◽  
...  

Contemporary adhesives use etch-and-rinse, self-etch, and multimode adhesive strategies. Simplified and universal adhesives present lower bond strength to dentin than conventional, two-bottle etch-and-rinse adhesives. The purpose of this study was to evaluate bonding performance of simplified and universal adhesives to dentin after modifying their application protocol (multiplying applications and extending application time). Adhesive layer thickness (ALT) and shear bond strength (SBS), as well as the correlation between these parameters was calculated. Two universal (Single Bond Universal and Prime & Bond One Select) and two self-etch adhesives (Adper Easy One and Xeno V) were tested. Significant differences in ALT were detected between the adhesives, as well as within the same adhesive between study groups. Tested adhesives presented the thinnest adhesive layer when applied 2 times in 20 s. Single Bond Universal obtained the highest SBS results of all adhesives. Most adhesives (except for Prime & Bond One Select) obtained the highest SBS, when applied two or three times in 40 or 60 s, respectively. No correlation between the ALT and SBS was found. The study showed that increasing the number of applications and extending the application time of self-etch and universal adhesives can be recommended to improve their performance.


2021 ◽  
Vol 45 (3) ◽  
pp. 186-192
Author(s):  
Min Jin Kim ◽  
Joonhee Kim ◽  
Ji-Soo Song ◽  
Shin Hye Chung ◽  
Hong-Keun Hyun

Objective: To compare the shear bond strength (SBS) after thermocycling of four universal adhesives applied in self-etch mode on dentin and etch-and-rinse mode on enamel. Study design: Flat 144 buccal or lingual dentin and enamel surfaces from 72 non-carious primary molars were prepared. Samples were segregated into 12 groups (n=12): Adper Single Bond 2 etch-and-rinse (SB_T) and Clearfil SE Bond self-etch (SE_S) applied to enamel and dentin served as controls. Scotch Bond Universal Adhesive (SBU), Clearfil S3 Bond Universal Adhesive (SEU), Tetric N-Bond Universal Adhesive (TEN), and All Bond Universal (BIS) were applied in etch-and-rinse mode to enamel and in self-etch mode to dentin. They were thermocycled for 5000 cycles. SBS testing and the evaluation of fracture mode were performed. Results: SB_T showed statistically higher SBS than other adhesive groups using etch-and-rinse mode on enamel. SE_S and BIS had statistically higher SBS than other adhesive groups using self-etch mode on dentin. Mixed failure was the most common failure mode in each group. Conclusion: The universal adhesives did not show higher SBS than SB_T when using etch-and-rinse on enamel. All universal adhesives showed higher SBS than SB_T and had SBS similar to SE_S, except SBU when using self-etch mode on dentin.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2021 ◽  
Vol 24 (2) ◽  
Author(s):  
Fateme Vasei ◽  
Farahnaz Sharafeddin

Objective: To assess the shear bond strength (SBS) of resin composite to deep dentin, using 1 and 2.5% chitosan pretreatment as well as different adhesive systems. Material and Methods: 80 human maxillary molars were randomly divided to eight groups according to the type of adhesive system and dentin pretreatment (n = 10): I) two-step self-etch system (Clearfil SE bond); II) two-step etch-andrinse system (Adper single bond 2); III) 2.5% chitosan + Clearfil SE bond; IV) 2.5% chitosan +etch + Adper single bond 2; V) etch + 2.5% chitosan + Adper single bond 2; VI) 1% chitosan + Clearfil SE bond; VII) 1% chitosan + etch + Adper single bond 2; VIII) etch + 1% chitosan + Adper single bond 2 (chitosan solution (w/v): 2.5 g and 1 g of chitosan (Sigma Aldrich, USA) was dissolved in 100 ml of 1% acetic acid). Plastic molds were positioned on dentin and filled with composite (Z350, 3M ESPE, USA). SBS (MPa) was tested using a universal testing machine. ANOVA tests, Tukey’s test, and independent t test were used to analyze data (p < 0.05). Results: The highest SBS value among self-etch groups was observed with 1% chitosan (p = 0.001). In the etch-and-rinse group, the SBS of 1% chitosan was significantly lower than the other groups. Chitosan treatment following acid etching led to higher SBS in comparison to when chitosan was applied before etching, with the significant difference in 1% concentration (p = 0.030). A predominance of mix fractures was observed in dentin. Conclusion: Improved dentin bond strength can be achieved through immediate dentin pretreatment with 1% chitosan in self-etch adhesive systems. Chitosan Pretreatment may not be advantageous for etch-and-rinse adhesive systems. Keywords Adhesive system; Chitosan; Deep dentin; Shear strength.


2017 ◽  
Vol 46 (5) ◽  
pp. 273-277
Author(s):  
Clecila MÜLLER ◽  
Gabriela Cauduro da ROSA ◽  
Gabriela Simões TEIXEIRA ◽  
Ivo KREJCI ◽  
Tissiana BORTOLOTTO ◽  
...  

Abstract Objective To evaluate the influence of caries-affected dentin on bond strength of a universal one-step and a multi-step etch-and-rinse adhesive system. Material and method Enamel of 60 third human molars with and without caries was removed to expose dentin. The teeth were randomly assigned to six groups: Single Bond Universal (3M ESPE, St. Paul, MN, USA) in etch-and-rinse and in self-etch mode and Prime & Bond NT (Dentsply Co, Konstanz, Germany), all on sound and caries-affected dentin. Smear layer of the 30 sound dentin specimens was standardized by polishing with 600-grit SiC paper under water cooling. Residual infected dentin of the 30 caries-affected specimens was removed with a number 4 CA carbide bur until no caries smooth tissue was detectable by tactile-visual inspection. Cylinders of a light cured composite resin (Filtek Z350 XT, 3M ESPE) were built up using starch tubes and microshear test was performed until failure. The data was analyzed by one-way ANOVA and Tukey’s post hoc test. Result Significant differences in microshear bond strength (μSBS) were observed for the caries-affected groups, but not for sound dentin. The μSBS of Single Bond Universal were not influenced by the application protocol on sound dentin, however they were lower in the caries-affected group with both application protocols. The μSBS for Prime & Bond NT was not influenced by the dentin conditions. Conclusion Caries-affected dentin decrease in bond strength of Single Bond Universal in comparison to sound dentin. The bond strength of Prime & Bond NT was not altered by substrate conditions.


2015 ◽  
Vol 40 (4) ◽  
pp. 410-417 ◽  
Author(s):  
DE McLean ◽  
EJ Meyers ◽  
VL Guillory ◽  
KS Vandewalle

SUMMARY Purpose Universal bonding agents have been introduced for use as self-etch or etch-and-rinse adhesives depending on the dental substrate and clinician's preference. The purpose of this study was to evaluate the shear bond strength (SBS) of composite to enamel using universal adhesives compared to a self-etch adhesive when applied in self-etch and etch-and-rinse modes over time. Methods and Materials Extracted human third molars were used to create 120 enamel specimens. The specimens were ground flat and randomly divided into three groups: two universal adhesives and one self-etch adhesive. Each group was then subdivided, with half the specimens bonded in self-etch mode and half in etch-and-rinse mode. The adhesives were applied as per manufacturers' instructions, and composite was bonded using a standardized mold and cured incrementally. The groups were further divided into two subgroups with 10 specimens each. One subgroup was stored for 24 hours and the second for six months in 37°C distilled water and tested in shear. Failure mode was also determined for each specimen. Results A three-way analysis of variance (ANOVA) found a significant difference between groups based on bonding agent (p&lt;0.001) and surface treatment (p&lt;0.001) but not on time (p=0.943), with no significant interaction (p&gt;0.05). Clearfil SE in etch-and-rinse and self-etch modes had more mixed fractures than either universal adhesive in either mode. Conclusions Etching enamel significantly increased the SBS of composite to enamel. Clearfil SE had significantly greater bond strength to enamel than either universal adhesive, which were not significantly different from each other.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Author(s):  
Sara Valizadeh ◽  
Aida Moradi ◽  
Mansooreh Mirazei ◽  
Hooman Amiri ◽  
Mohammad Javad Kharazifard

Objectives: The aim of this study was to compare the microshear bond strength (µSBS) of various adhesive systems to dentin. Materials and Methods: In this in vitro experimental study, 60 sound human third molars were divided into four groups. Dentin discs were prepared of middle-third dentin measuring 4 mm in diameter and 2 mm in thickness. Dentin surfaces were bonded with one of the four types of adhesives: (A) Single Bond (3M ESPE), Scotchbond Universal (3M ESPE) in etch and rinse (B) and self-etch (C) modes and (D) Clearfil SE Bond (Kuraray Noritake Dental). After the application of adhesive systems according to the manufacturers’ instructions, composite cylinders (Vit-l-escence) were bonded to dentin surfaces. The μSBS test was performed using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed with one-way ANOVA and Tukey’s test (α=0.05). Results: The µSBS was the highest in self-etch Scotchbond Universal (15.8±6.08 MPa) followed by Clearfil SE Bond (15.24±4.6 MPa), etch and rinse Scotchbond Universal (11.68±4.07MPa) and Single Bond (11.24±3.74 MPa). A significant difference was only found between Single Bond and etch and rinse Scotchbond Universal groups (P=0.04). Conclusion: Based on the results of this study, application of Scotchbond Universal in self-etch mode provides a reliable bond to dentin.


Sign in / Sign up

Export Citation Format

Share Document