scholarly journals Laboratory Determination of Coal Dust Cleaning Efficacy of a Fibrous Filter for Flooded-Bed Dust Scrubber

Minerals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 295
Author(s):  
Neeraj Gupta ◽  
Ashish Ranjan Kumar ◽  
Steven Schafrik

Fibrous-type dust filters are used in flooded-bed dust scrubbers to capture dust from underground room and pillar mining atmospheres. They have 10–30 layers of finely woven strands that trap particles through the interception and impaction process. A full-cone water spray is installed upstream of the filter, which floods the screen. A scrubber’s efficacy is usually measured and reported in terms of reduction in gravimetric dust concentration at a known location in a mine. This paper reports the particle-size-dependent dust removal efficiency of a fibrous filter obtained from an instrumented test-set up. A variable frequency drive and an inline flow control knob were used to control the airflow through the filter and water flow onto the filter. Optical particle counting of coal dust particles upstream and downstream was carried out to determine the cleaning efficacy. Experiments showed an increase in cleaning efficiency for all the dust particles with their size. A progressive decrease in dust concentration downstream of the filter with an increase in water flow through the nozzle affirmed the capture of dust particles by water sprays.

2013 ◽  
Vol 313-314 ◽  
pp. 702-705
Author(s):  
Shao Cheng Ge ◽  
Yao Xuan Feng ◽  
De Ji Jing

For getting the effectiveof application in dissipation dust law with particle motion equation atcoal handling system of belt machine tail, must be to proceed related numerical simulation in the way of dust particles motion incoal handling system of belt machine tail and dust concentration of diffusion inoperation space. Application particlemotion equation theory for numerical simulation to coal dustparticles, obtained dust coal dissipation law in coal handling system, at thesame time combine with the data of the field test of dust concentration andfallout dispersion for analyzing and comparing. The results of comparison showthat: the data of numerical simulation with particle motion equationin coal dust dissipation law is coincide with reality dissipation law. Accordingto the conclusion of this research, it is provides theoretical basis forprevention and treatment in coal mine of coal handling system of dustdissipation.


2021 ◽  
Author(s):  
Ashish Ranjan Kumar ◽  
Neeraj Gupta ◽  
Steven Schafrik

Abstract Fibrous-type filters are used to capture dust particles in mining and other occupations where personnel are exposed for prolonged periods. Dust cleansing systems including flooded-bed dust scrubbers use these mesh-type multi-layered filters. These filters trap dust particles efficiently on their surface and inside their mesh. However, their continued operation leads to dust build-up and subsequent clogging. This results in increased resistance of the filter and lowered airflow rate through the scrubber. This could potentially enhance the exposure of the miners. A non-clogging self-cleaning impingement screen type dust filter was designed by the authors for use in mining and industrial dust cleansing applications. The filter guides dirt-laden air through rapidly turning paths which forces it to shed heavier particles. The particles impact one of the impermeable solid metallic filter surfaces and are removed from the airstream. A full cone water spray installed upstream prevents any surface build-up of dust. This paper summaries the computer models generated to show the filter operations and laboratory experiments including optical particle counting to establish the cleaning efficiency.


Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5527
Author(s):  
Dominik Bałaga ◽  
Marek Kalita ◽  
Piotr Dobrzaniecki ◽  
Sebastian Jendrysik ◽  
Krzysztof Kaczmarczyk ◽  
...  

The method of analyzing the results of dust concentration measurements in mine workings that was conducted within the ROCD (Reducing risks from Occupational exposure to Coal Dust) European project using the developed dust prediction algorithm is presented. The analysis was based on the measurements of average dust concentration with the use of the CIP-10R gravimetric dust meters, for the respirable PM4 dust concentration, and IPSQ analyzer for instantaneous concentration measurements (including PM2.5 dust) and with the use of Pł-2 optical dust meters for instantaneous concentration measurements of PM10 dust. Based on the analyses of the measurement results, the characteristics of the distribution of PM10, PM4, and PM2.5 dust particles were developed for the tested dust sources. Then, functional models based on power functions were developed. The determined models (functions) allow predicting the dust distribution in such conditions (and places) for which we do not have empirical data. The developed models were implemented in a specially developed online tool, which enables predicting the concentration of PM10, PM4, and PM2.5 dust (on the basis of dust concentration of one source) at any distance from the dust source.


1996 ◽  
Vol 150 ◽  
pp. 409-413
Author(s):  
Patrick P. Combet ◽  
Philippe L. Lamy

AbstractWe have set up an experimental device to optically study the scattering properties of dust particles. Measurements over the 8 — 174° interval of scattering angles are performed on a continuously flowing dust loaded jet illuminated by a polarized red HeNe laser beam. The scattering is averaged over the population of the dust particles in the jet, which can be determined independently, and give the “volume scattering function” for the two directions of polarization directly. While results for spherical particles are in good agreement with Mie theory, those for arbitrary particles show conspicuous deviations.


Author(s):  
Xin Luan ◽  
Zhongli Ji ◽  
Longfei Liu ◽  
Ruifeng Wang

Rigid filters made of ceramic or metal are widely used to remove solid particles from hot gases at temperature above 260 °C in the petrochemical and coal industries. Pulse-jet cleaning of fine dust from rigid filter candles plays a critical role in the long-term operation of these filters. In this study, an experimental apparatus was fabricated to investigate the behavior of a 2050 mm filter candle, which included monitoring the variation of pressure dynamic characteristics over time and observing the release of dust layers that allowed an analysis of the cleaning performance of ISO 12103-1 test dusts with different particle size distributions. These results showed the release behavior of these dusts could be divided into five stages: radial expansion, axial crack, flaky release, irregular disruption and secondary deposition. The cleaning performance of smaller sized dust particles was less efficient as compared with larger sized dust particles under the same operating conditions primarily because large, flaky-shaped dust aggregates formed during the first three stages were easily broken into smaller, dispersed fragments during irregular disruption that forced more particles back to the filter surface during secondary deposition. Also, a “low-pressure and long-pulse width” cleaning method improved the cleaning efficiency of the A1 ultrafine test dust from 81.4% to 95.9%.


2016 ◽  
Vol 2016 ◽  
pp. 1-13 ◽  
Author(s):  
Wen-Zheng Wang ◽  
Yan-Ming Wang ◽  
Guo-Qing Shi

Respirable coal particle generated during underground mining is the main cause for gas-dust explosions and coal workers’ pneumoconiosis (CWP) which needs accurate monitoring especially on its concentration. Focusing on the coal dust pollution in the fully mechanized working face of Huangbaici coalmine, coal particle was sampled for further industrial analysis and FT-IR test to obtain its chemical composition and optical constant. Combined with the simulated spatial distribution of airborne dust, the spectral transmission characteristics of coal dust within wavelengths of 2.5 to 25 μm under different operating conditions were obtained. The simulation results show that the transmittance and aerosol optical depth (AOD) of coal dust are closely linked and obviously influenced by the variation of dust generation source (intensity of dust release, position of coal cutting, and the wetting of the coal seam) and airflow field (wind speed and direction of ventilation). Furthermore, an optical channel of 1260–1280 cm−1(7.937–7.813 μm) which is almost only sensitive to the variation of dust concentration but dull to the diameter change of coal dust was selected to establish the correlation of dust concentration and infrared transmittance. The fitting curve was then applied to retrieve the equivalent dust concentration based on optical information, and the comparison results demonstrate that the estimated pollution level is consistent with field measurement data in engineering practice.


2021 ◽  
Vol 132 ◽  
pp. 103506
Author(s):  
Zheng Wang ◽  
Xu Zheng ◽  
Dongyan Li ◽  
Helin Zhang ◽  
Yi Yang ◽  
...  
Keyword(s):  

Author(s):  
K.M. Moiseeva ◽  
◽  
A.Yu. Krainov ◽  
E.I. Rozhkova ◽  
◽  
...  

Swirling combustion is currently one of the most important engineering problems in physics of combustion. There is a hypothesis on the increase in the combustion efficiency of reacting gas mixtures in combustion chambers with swirling flows, as well as on the increase in the efficiency of fuel combustion devices. In this paper, it is proposed to simulate a swirling flow by taking into account the angular component of the flow velocity. The aim of the study is to determine the effect of the angular component of the flow velocity on the characteristics of the flow and combustion of an air suspension of coal dust in a pipe. The problem is solved in a twodimensional axisymmetric approximation with allowance for a swirling flow. A physical and mathematical model is based on the approaches of the mechanics of multiphase reacting media. A solution method involves the arbitrary discontinuity decay algorithm. The impact of the flow swirl and the size of coal dust particles on the gas temperature distribution along the pipe is determined.


2017 ◽  
Vol 17 (3) ◽  
pp. 2401-2421 ◽  
Author(s):  
Siyu Chen ◽  
Jianping Huang ◽  
Litai Kang ◽  
Hao Wang ◽  
Xiaojun Ma ◽  
...  

Abstract. The Weather Research and Forecasting Model with chemistry (WRF-Chem model) was used to investigate a typical dust storm event that occurred from 18 to 23 March 2010 and swept across almost all of China, Japan, and Korea. The spatial and temporal variations in dust aerosols and the meteorological conditions over East Asia were well reproduced by the WRF-Chem model. The simulation results were used to further investigate the details of processes related to dust emission, long-range transport, and radiative effects of dust aerosols over the Taklimakan Desert (TD) and Gobi Desert (GD). The results indicated that weather conditions, topography, and surface types in dust source regions may influence dust emission, uplift height, and transport at the regional scale. The GD was located in the warm zone in advance of the cold front in this case. Rapidly warming surface temperatures and cold air advection at high levels caused strong instability in the atmosphere, which strengthened the downward momentum transported from the middle and low troposphere and caused strong surface winds. Moreover, the GD is located in a relatively flat, high-altitude region influenced by the confluence of the northern and southern westerly jets. Therefore, the GD dust particles were easily lofted to 4 km and were the primary contributor to the dust concentration over East Asia. In the dust budget analysis, the dust emission flux over the TD was 27.2 ± 4.1 µg m−2 s−1, which was similar to that over the GD (29 ± 3.6 µg m−2 s−1). However, the transport contribution of the TD dust (up to 0.8 ton d−1) to the dust sink was much smaller than that of the GD dust (up to 3.7 ton d−1) because of the complex terrain and the prevailing wind in the TD. Notably, a small amount of the TD dust (PM2.5 dust concentration of approximately 8.7 µg m−3) was lofted to above 5 km and transported over greater distances under the influence of the westerly jets. Moreover, the direct radiative forcing induced by dust was estimated to be −3 and −7 W m−2 at the top of the atmosphere, −8 and −10 W m−2 at the surface, and +5 and +3 W m−2 in the atmosphere over the TD and GD, respectively. This study provides confidence for further understanding the climate effects of the GD dust.


Sign in / Sign up

Export Citation Format

Share Document