scholarly journals Rapid 3 s Curing: What Happens in Deep Layers of New Bulk-Fill Composites?

Materials ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 515
Author(s):  
Danijela Marovic ◽  
Matej Par ◽  
Ana Crnadak ◽  
Andjelina Sekelja ◽  
Visnja Negovetic Mandic ◽  
...  

This study assessed the influence of rapid 3 s light curing on the new generation of bulk-fill resin composites under the simulated aging challenge and depths up to 4 mm. Four bulk-fill materials were tested: two materials designed for rapid curing (Tetric PowerFill—PFILL; Tetric PowerFlow—PFLW) and two regular materials (Filtek One Bulk Fill Restorative—FIL; SDR Plus Bulk Fill Flowable—SDR). Three-point bending (n = 10) was used to measure flexural strength (FS) and flexural modulus (FM). In the 3 s group, two 2 mm thick specimens were stacked to obtain 4 mm thickness, while 2 mm-thick specimens were used for ISO group. Specimens were aged for 1, 30, or 30 + 3 days in ethanol. The degree of conversion (DC) up to 4 mm was measured by Raman spectroscopy. There was no difference between curing protocols in FS after 1 day for all materials except PFLW. FM was higher for all materials for ISO curing protocol. Mechanical properties deteriorated by increasing depth (2–4 mm) and aging. ISO curing induced higher DC for PFLW and FIL, while 3 s curing was sufficient for PFILL and SDR. The 3 s curing negatively affected FM of all tested materials, whereas its influence on FS and DC was highly material-specific.

2015 ◽  
Vol 40 (2) ◽  
pp. 181-189 ◽  
Author(s):  
M D'Amario ◽  
F De Angelis ◽  
M Vadini ◽  
N Marchili ◽  
S Mummolo ◽  
...  

SUMMARY The aim of this study was to assess the flexural strength, flexural elastic modulus and Vickers microhardness of three resin composites prepared at room temperature or cured after one or repeated preheating cycles to a temperature of 39°C. Three resin composites were evaluated: Enamel Plus HFO (Micerium), Opallis (FGM), and Ceram X Duo (Dentsply DeTrey). For each trial, one group of specimens of each material was fabricated under ambient laboratory conditions, whereas in the other groups, the composites were cured after 1, 10, 20, 30, or 40 preheating cycles to a temperature of 39°C in a preheating device. Ten rectangular prismatic specimens (25 × 2 × 2 mm) were prepared for each group (N=180; n=10) and subjected to a three-point bending test for flexural strength and flexural modulus evaluation. Vickers microhardness was assessed on 10 cylindrical specimens from each group (N=180; n=10). Statistical analysis showed that, regardless of the material, the number of heating cycles was not a significant factor and was unable to influence the three mechanical properties tested. However, a significant main effect of the employed material on the marginal means of the three dependent variables was detected.


2012 ◽  
Vol 23 (5) ◽  
pp. 508-514 ◽  
Author(s):  
Vinícius E. S. Gajewski ◽  
Carmem S. Pfeifer ◽  
Nívea R. G. Fróes-Salgado ◽  
Letícia C. C. Boaro ◽  
Roberto R. Braga

The organic phase of resin composites is constituted by dimethacrylate resins, the most common monomers being the bisphenol A diglycidildimethacrylate (BisGMA), its ethoxylated version (BisEMA), triethylene glycol dimethacrylate (TEGDMA) and urethane dimethacrylate (UDMA). This study compared the homopolymers formed from the monomers used in restorative dental composites in terms of their degree of conversion (DC) and reaction kinetics (by near infra-red spectroscopy, n=3), mechanical properties (flexural modulus and strength in three point-bending, FM and FS, respectively, n=15), water sorption and solubility (WS and SL, respectively - ISO 4049, n=5). Materials were made photopolymerizable by the addition of camphoroquinone/dimethylamine ethyl methacrylate. TEGDMA showed the highest DC, followed by BisEMA, UDMA and BisGMA, both at 10 min and at 24h (p<0.001). UDMA showed the highest rate of polymerization, followed by TEGDMA, BisEMA and BisGMA (H0=13.254, p<0.001). UDMA and TEGDMA presented similar FM, significantly higher (p<0.001) than BisEMA and BisGMA, which in turn present statistically similar values (p>0.001). For FS, UDMA presented the highest value (p<0.001), followed by TEGDMA, then by BisEMA and BisGMA, which were statistically similar (p>0.001). BisGMA showed the highest WS, and TEGDMA and BisEMA the lowest. UDMA was statistically similar to all (H0=16.074, p<0.001). TEGDMA presented the highest SL, followed by UDMA, BisGMA and BisEMA (p<0.001). The tested homopolymers presented different behaviors in terms of polymerization kinetics, flexural properties, water sorption and solubility. Therefore, the use of copolymers is justified in order to obtain high DC and mechanical properties, as well as good resistance to water degradation.


10.2341/07-81 ◽  
2008 ◽  
Vol 33 (3) ◽  
pp. 287-293 ◽  
Author(s):  
E. M. da Silva ◽  
L. T. Poskus ◽  
J. G. A. Guimarães

Clinical Relevance The nanofilled composite presented a lower degree of conversion, flexural modulus and flexural strength than the hybrid composite. On the other hand, the two materials had a similar hardness. The light polymerization mode influenced only the degree of conversion and the hardness of composites.


2007 ◽  
Vol 14 (04) ◽  
pp. 817-820
Author(s):  
MIN HUANG ◽  
KE-ZHI LI ◽  
HE-JUN LI ◽  
QIAN-GANG FU ◽  
GUO-DONG SUN

SiC coating for carbon/carbon composites was prepared by pack cementation method. The effects of coating process on the microstructure and the mechanical properties of C / C composites were analyzed by SEM and three-point bending test, respectively. As the infiltrated Si improved the interfaces bonding during the coating process, the flexural strength and flexural modulus of SiC -coated carbon/carbon composites were both increased by about 10% than the naked C / C composites. In addition, the mechanism of the change of failure mode of SiC coated C / C composites and naked C / C composites was addressed.


Materials ◽  
2020 ◽  
Vol 13 (6) ◽  
pp. 1477 ◽  
Author(s):  
Ioana-Codruţa Mirică ◽  
Gabriel Furtos ◽  
Bogdan Bâldea ◽  
Ondine Lucaciu ◽  
Aranka Ilea ◽  
...  

The aim of this study was to evaluate the correlation between the percent of inorganic filler by weight (wt. %) and by volume (vol. %) of 11 flowable resin composites (FRCs) and their mechanical properties. To establish the correlation, the quantity of inorganic filler was determined by combustion and shape/size analyzed by SEM images. The compressive strength (CS), flexural strength (FS), and flexural modulus (FM) were determined. The CS values were between 182.87-310.38 MPa, the FS values ranged between 59.59 and 96.95 MPa, and the FM values were between 2.34 and 6.23 GPa. The percentage of inorganic filler registered values situated between 52.25 and 69.64 wt. % and 35.35 and 53.50 vol. %. There was a very good correlation between CS, FS, and FM vs. the inorganic filler by wt. % and vol. %. (R2 = 0.8899–0.9483). The highest regression was obtained for the FM values vs. vol. %. SEM images of the tested FRCs showed hybrid inorganic filler for Filtek Supreme XT (A3) and StarFlow (A2) and a homogeneous type of inorganic filler for the other investigated materials. All of the FS values were above 50 MPa, the ISO 4049/2019 limit for FRCs.


2020 ◽  
Vol 2 (1) ◽  
pp. 45-52
Author(s):  
Ana C. de Assunção Oliveira ◽  
Sandro Griza ◽  
Rafael R. de Moraes ◽  
André L. Faria-e-Silva

Objective:: To investigate the effect of filler content and the time spent before light-curing on mechanical properties of dual-cured cement. Methods:: Experimental dual-cured resin cements were formulated with 60, 65 or 68wt% of filler. The viscosity of experimental cement was measured using a digital viscometer. Bar-shaped specimens (25 x 2 x 2 mm) were fabricated, while the light-curing was started immediately or 5 minutes after the insertion of cement into the mold (n = 7). A three-point bending test was performed and the values of flexural strength and elastic modulus were measured. The Vickers hardness of fractured specimens was measured on the surface of the cement. Data from viscosity were submitted to oneway ANOVA, while the data from mechanical properties were analyzed by two-way ANOVA. All pair-wise comparisons were performed using Tukey’s test (α = 0.05). Results:: The experimental cement with 68wt% of filler showed the highest viscosity and those with 60wt% showed the the lowest viscosity. Irrespective of the time spent before light-curing, the cement with 65wt% of filler presented the highest values of flexural strength and elastic modulus. The addition of 60wt% of filler resulted in the lowest elastic modulus, while 68wt% of filler resulted in lowest flexural strength. Regarding the hardness, the cement with 68wt% of filler showed the highest values, while there was no difference between 60 and 65wt% of filler. Conclusion:: Filler content affected the mechanical properties of the experimental cement and this effect did not depend on the waiting time before the light-curing procedure.


1992 ◽  
Vol 71 (11) ◽  
pp. 1847-1850 ◽  
Author(s):  
A. Peutzfeldt ◽  
E. Asmussen

The present study investigated a concept for additional crosslinking of dental polymers, by which resistance to wear of resin composites might be increased. Bifunctional ketones were added to monomer mixtures, which were then made light-curing and loaded with filler. The monomer mixtures were varied with respect to type and ratio of monomer and ketone. For measurement of possible effects of the cross-linking agents added, four mechanical properties of the experimental resin composites were determined. Addition of the bifunctional ketone diacetyl resulted in the following increases in mechanical properties: diametral tensile strength, 11%; flexural strength, 29%; modulus of elasticity, 19%; and modulus of resilience, 50%.


Materials ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 4919
Author(s):  
Wojciech Grzebieluch ◽  
Piotr Kowalewski ◽  
Dominika Grygier ◽  
Małgorzata Rutkowska-Gorczyca ◽  
Marcin Kozakiewicz ◽  
...  

Thanks to the continuous development of light-curing resin composites it is now possible to print permanent single-tooth restorations. The purpose of this study was to compare resin composites for milling -Gandio Blocks(GR), Brilliant Crios(CR) and Enamic(EN) with resin composite for 3D printing—VarseoSmileCrown plus(VSC). Three-point bending was used to measure flexural strength (σf) and flexural modulus (Ef). The microhardness was measured using a Vickers method, while fractographic, microstructural, texture and fractal dimension (FD) analyses were performed using SEM, optical microscope and picture analysis methods. The values of σf ranged from 118.96 (±2.81) MPa for EN to 186.02 (±10.49) MPa for GR, and the values of Ef ranged from 4.37 (±0.8) GPa for VSC to 28.55 (±0.34) GPa for EN. HV01 ranged from 25.8 (±0.7) for VSC to 273.42 (±27.11) for EN. The filler content ranged from 19–24 vol. % for VSC to 70–80 vol. % for GR and EN. The observed fractures are typical for brittle materials. The correlation between FD of materials microstructure and Ef was observed. σf of the printed resin depends on layers orientation and is significantly lower than σf of GR and CR. Ef of the printed material is significantly lower than Ef of blocks for milling.


Coatings ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 1255
Author(s):  
Monika Domarecka ◽  
Agata Szczesio-Wlodarczyk ◽  
Michał Krasowski ◽  
Magdalena Fronczek ◽  
Tomasz Gozdek ◽  
...  

Dual-curing composites have a wide spectrum of use in practice (rebuilding, reconstruction, and luting). The characterization of this type of material and comparative study of selected mechanical properties with light-cured materials were carried out for this paper. In this study, we used six materials with a dual-cure system—Bulk EZ, Fill-Up!, StarFill 2B, Rebilda DC, MultiCore Flow, Activa Bioactive-Restorative—and three light-cured materials—Filtek Bulk Fill Posterior, Charisma Classic, and G-aenial Universal Flo. The materials were conditioned for 24 h in water at 37 °C before testing. Selected material properties were determined: three-point bending flexural strength, diametral tensile strength, hardness, microhardness, and shrinkage stress. The highest three-point bending flexural strength (TPB) was 137.0 MPa (G-aenial Universal Flo), while the lowest amounted to 86.5 MPa (Activa Bioactive). The diametral tensile strength (DTS) values were in a range from 39.2 MPa (Rebilda DC) to 54.1 MPa (Charisma Classic). The lowest hardness (HV) value of 26 was obtained by the Activa Bioactive material, while the highest values were recorded for Filtek Bulk Fill Posterior and Charisma Classic-53. The shrinkage stress of the tested materials ranged from 6.3 MPa (Charisma Classic) to 13.2 MPa (G-aenial Universal Flo). Dual-curing composites were found to have similar properties to light-cured composites.