scholarly journals A Prediction Model of the Concrete Cracking Induced by the Non-Uniform Corrosion of the Steel Reinforcement

Materials ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 830 ◽  
Author(s):  
Wenjun ZHU ◽  
Kequan YU ◽  
Yude XU ◽  
Kai ZHANG ◽  
Xiaopei CAI

This paper investigates the influence of non-uniform corrosion in the transversal direction of the steel reinforcement on the cracking propagation of the concrete cover. An analytical model is proposed for the prediction of the corrosion-induced cracking performance. Both the thick cylinder theory of the concrete and the effect of transversal non-uniform corrosion of the steel reinforcement are involved by considering the corrosion layer of the corrosion products and a layer of concrete with the corrosion products filled with the pores. A three-stage corrosion-induced cracking of the concrete is proposed: corrosion without expansive stress to the concrete, corrosion with expansive stress to the adjacent concrete, as well as the corrosion-induced cracking of the concrete. By considering the non-uniform corrosion of the steel reinforcement and the tensile stress induced by the volumetric expansion of the corrosion products, the cracking initiation resulting from the non-uniform corrosion was involved in the prediction model. The models were also validated by the experimental results from both the corroded specimens and the existing literature, which would be helpful for the evaluation of the existing reinforced concrete constructions in the marine environment.

Author(s):  
Huaishuai Shang ◽  
Jirui Liu

In this paper, the cracking of concrete cover caused by steel bar corrosion was discussed and studied based on the three-period model of steel bar corrosion in concrete. In the analysis, according to the non-uniformity of steel bar in reinforced concrete under natural environment, the contour of corrosion layer is simplified into a semi-ellipse. The steel bar corrosion was divided into three different periods by two corrosion points, namely, the void to be filled was exactly filled and the concrete cover was exactly cracked. Different model assumptions are made for each corrosion period. Before the concrete cover cracks, it is developed into an elastic plate. Based on the theory of elastic mechanics, the maximum corrosion depth of steel bar when concrete cover cracks is predicted.....


Materials ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4245 ◽  
Author(s):  
Lu Zhang ◽  
Ditao Niu ◽  
Bo Wen ◽  
Daming Luo

The volume expansion of reinforcement corrosion products resulting from the corrosion of steel reinforcement embedded into concrete causes the concrete’s protective layer to crack or spall, reducing the durability of the concrete structure. Thus, it is necessary to analyze concrete cracking caused by reinforcement corrosion. This study focused on the occurrence of non-uniform reinforcement corrosion in a natural environment. The characteristics of the rust layer were used to deduce the unequal radial displacement distribution function of concrete around both angular and non-angular bars. Additionally, the relationship between the corrosion ratio and the radial displacement of the concrete around the bar was established quantitatively. Concrete cracking due to the non-uniform corrosion of reinforcements was simulated using steel bars embedded in concrete that were of uneven displacement because of rust expansion. The distribution of the principal tensile stress around the bar was examined. A formula for calculating the critical radial displacement at the point when cracking began was obtained and used to predict the corrosion ratio of the concrete cover. The determined analytical corrosion ratio agreed well with the test result. The effect factor analysis based on the finite element method indicated that increasing the concrete strength and concrete cover thickness delays concrete cracking and that the adjacent rebar causes the stress superposition phenomenon.


2012 ◽  
Vol 204-208 ◽  
pp. 1159-1163
Author(s):  
Gang Chen ◽  
Shuai Yuan ◽  
Yu Bo Peng ◽  
Wei Jun Yang

The objective of this work is to find the law of combined effect of steel reinforcement and expansion agent (EA) on the crack resistance of ready-mixed concrete by doing flat-plate method experimental study on the crack resistance of ready-mixed concrete with EA, also with EA and steel reinforcement, with a deep analysis of the mechanism of reinforcement and EA on ready-mixed concrete. The paper comes to the role of ready-mixed concrete cracking performance which is influenced by reinforcement steel and EA.


2020 ◽  
Vol 24 (1) ◽  
pp. 11-16
Author(s):  
Saddam - Husein ◽  
Rudy Djamaluddin ◽  
Rita Irmawaty ◽  
Kusnadi Kusnadi

SADDAM HUSEIN. Analisa Pola Kegagalan Balok Beton Menggunakan GFRP Bar Tanpa Selimut Beton (dibimbing oleh Rudi Djamaluddin dan Rita Irmawaty) Struktur beton bertulang yang menggunakan tulangan baja pada daerah korosif, menjadi rawan terhadap kerusakan atau penurunan kekuatannya akibat korosi.Korosi pada tulangan baja merupakan salah satu faktor penyebab menurunnya kekuatan struktur beton bertulang. Salah satu material yang dikembangkan mengatasi korosi adalah penggunaan material tulangan GFRP (Glass Fiber Reinforced Polymer). Penelitian ini bertujuan untuk menganalisa kapasitas lentur dan pola kegagalan balok beton tanpa selimut dengan menggunakan material tulangan GFRP bar.   Desain penelitian merupakan eksperimental laboratorium dengan rekapitulasi sebanyak 6 sampel yang terdiri dari 2 Balok beton menggunakan tulangan baja dengan selimut beton, 2 balok beton menggunakan tulangan GFRP bar dengan selimut beton, 2 balok beton menggunakan GFRP bar tanpa selimut beton. Metode pengujian dilakukan dengan dengan pengujian lentur statik monotonik dan Analisis data menggunakan uji kondisi retak awal dan kondisi ultimit.   Hasil penelitian ini menunjukkan bahwa kapasitas lentur pada balok dengan tulangan GFRP bar lebih besar dibandingkan dengan balok tulangan baja dan mampu meningkatkan kapasitas lentur balok dalam menahan beban sebesar 39.76 %, pola kegagalan beton yang terjadi pada balok tulangan baja mengalami kegagalan lentur tekan ditandai dengan retakan yang terjadi pada sisi tertekan dan membentuk retakan tegak dengan sumbu netral beton yang tertekan, sedangkan pada balok beton tulangan GFRP tanpa selimut mengalami kegagalan keruntuhan tekan geser dengan kondisi tulangan berdeformasi (bi-linear) dengan retak miring dan secara tiba-tiba menjalar menuju sumbu netral beton yang tertekan sehingga terjadilah keruntuhan secara tiba-tiba.     SADDAM HUSEIN.Failure mode analysis of concrete Beams Using GFRP rebar Without concrete cover (supervised by Rudi Djamaluddin and Rita Irmawaty)   Reinforced concrete that uses rebar steel in corrosive areas, are prone to damage or decreased strength due to corrosion. Corrosion in the steel reinforcement is one of the factors that decreasing strength of reinforced concrete. One of the materials developed to overcome corrosion is the use of GFRP (Glass Fiber Reinforced Polymer) reinforcement material. This study aims to analyze the flexural capacity and failure mode of concrete beams without concrete cover using material GFRP bar as reinforcement.   The research design was an experimental laboratory with a recapitulation of 6 samples consisting of 2 beams using steel reinforcement with concrete cover.2 concrete beams using reinforcement GFRP bar with concrete cover, 2 beams using GFRP bars without concrete cover. The  research method uses the monotonic static flexure and analyzing the data using the initial crack condition and ultimate conditions test.   The results of the research indicate the flexural capacity of the beams with GFRP bar reinforcement is higher than steel reinforcement beams and can increase 39.76% of the flexural capacity of the beams in holding loads , the failure mode analysis occurs in steel reinforcing beam experiences compressive failure. Failure was characterized  by cracks that occur on the depressing side and form an upright crack with the neutral axis of the compressed concrete, whereas in GFRP reinforced concrete beams without concrete cover, failure of shear compression with conditions of deformed reinforcement (bi-linear) with sloping cracks and suddenly spread towards the neutral axis of the compressed concrete so that there was a sudden collapse.


Materials ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 295 ◽  
Author(s):  
Sébastien Champagne ◽  
Ehsan Mostaed ◽  
Fariba Safizadeh ◽  
Edward Ghali ◽  
Maurizio Vedani ◽  
...  

Absorbable metals have potential for making in-demand rigid temporary stents for the treatment of urinary tract obstruction, where polymers have reached their limits. In this work, in vitro degradation behavior of absorbable zinc alloys in artificial urine was studied using electrochemical methods and advanced surface characterization techniques with a comparison to a magnesium alloy. The results showed that pure zinc and its alloys (Zn–0.5Mg, Zn–1Mg, Zn–0.5Al) exhibited slower corrosion than pure magnesium and an Mg–2Zn–1Mn alloy. The corrosion layer was composed mostly of hydroxide, carbonate, and phosphate, without calcium content for the zinc group. Among all tested metals, the Zn–0.5Al alloy exhibited a uniform corrosion layer with low affinity with the ions in artificial urine.


Materials ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 2923 ◽  
Author(s):  
Violetta K. Kytinou ◽  
Constantin E. Chalioris ◽  
Chris G. Karayannis ◽  
Anaxagoras Elenas

The use of fibers as mass reinforcement to delay cracking and to improve the strength and the post-cracking performance of reinforced concrete (RC) beams has been well documented. However, issues of common engineering practice about the beneficial effect of steel fibers to the seismic resistance of RC structural members in active earthquake zones have not yet been fully clarified. This study presents an experimental and a numerical approach to the aforementioned question. The hysteretic response of slender and deep steel fiber-reinforced concrete (SFRC) beams reinforced with steel reinforcement is investigated through tests of eleven beams subjected to reversal cyclic loading and numerical analysis using 3D finite element (FE) modeling. The experimental program includes flexural and shear-critical SFRC beams with different ratios of steel reinforcing bars (0.55% and 1.0%), closed stirrups (from 0 to 0.5%), and fibers with content from 0.5 to 3% per volume. The developed nonlinear FE numerical simulation considers well-established relationships for the compression and tensional behavior of SFRC that are based on test results. Specifically, a smeared crack model is proposed for the post-cracking behavior of SFRC under tension, which employs the fracture characteristics of the composite material using stress versus crack width curves with tension softening. Axial tension tests of prismatic SFRC specimens are also included in this study to support the experimental project and to verify the proposed model. Comparing the numerical results with the experimental ones it is revealed that the proposed model is efficient and accurately captures the crucial aspects of the response, such as the SFRC tension softening effect, the load versus deformation cyclic envelope and the influence of the fibers on the overall hysteretic performance. The findings of this study also reveal that SFRC beams showed enhanced cyclic behavior in terms of residual stiffness, load-bearing capacity, deformation, energy dissipation ability and cracking performance, maintaining their integrity through the imposed reversal cyclic tests.


2018 ◽  
Vol 199 ◽  
pp. 04004
Author(s):  
Ze Gyang Zakka ◽  
Mike Otieno

This paper presents results of an ongoing research of the effect of 1D and 2D chloride ingress on concrete resistivity and corrosion rate of steel reinforcement. 12 concrete beams made with concrete of binder blend PC(50)/GGBS(50), w/b = 0.40, 10 mm steel reinforcement rods at concrete cover of 20 mm were used in this laboratory based experiment. The steel reinforcement bars were placed at the middle or at an orthogonal corner of the concrete beams subjected to 1D and 2D chloride ingress respectively. A single crack was induced using 3-point bending on one-half of the beams. The beams were exposed to a repeated cycle of 2 weeks ponding in 5% NaCl and then air drying in ambient laboratory condition for 2 weeks. The corrosion rate of both cracked and uncracked specimens exposed to 2D chloride ingress was significantly higher than that of beams exposed to 1D chloride ingress. The uncracked specimens had lower concrete resistivity values compared to the cracked specimens even though higher corrosion rates were measured.


2018 ◽  
Vol 201 ◽  
pp. 366-384 ◽  
Author(s):  
Xudong Cheng ◽  
Qiaozhi Su ◽  
Fenglei Ma ◽  
Xinqian Liu ◽  
Xiaocen Liang

Sign in / Sign up

Export Citation Format

Share Document