scholarly journals Avoidance of Interaction between Impression Materials and Tooth Surface Treated for Immediate Dentin Sealing: An In Vitro Study

Materials ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3454 ◽  
Author(s):  
Bruna Sinjari ◽  
Gianmaria D’Addazio ◽  
Giovanna Murmura ◽  
Giorgio Di Vincenzo ◽  
Mario Semenza ◽  
...  

Immediate dentin sealing (IDS) is an advantageous approach for realizing adhesive restorations, but it interferes with the polymerization of impression material due to the oxygen-inhibition layer (OIL), which leaves residues of impression material on the teeth. The aim of this study is to identify a clinical surface cleaning protocol after IDS in order to achieve defect-free impressions. Sixty extracted human teeth were cut to expose fresh dentin and the IDS protocol was performed. Samples were divided into six groups where different surface cleaning protocols were made before taking impressions: G1S and G1P groups, IDS and silicone (S) or polyether (P) impressions; G2S and G2P, treatment with prophy paste and impressions; G3S and G3P, final cleaning phase with surfactant agent and impressions. Teeth were evaluated with a scanning electron microscope to identify the areas (expressed in mm2) where residual impression material was present. The results demonstrate a reduction of residues in the G2 groups and the total disappearance in G3 groups with statistically significant differences between them. Superficial cleaning protocols with the prophy paste and surfactant agent lead to the elimination of the interaction with impression materials and OIL. These results suggest a safe clinical protocol for obtaining defect-free impressions after IDS.

2013 ◽  
Vol 14 (2) ◽  
pp. 265-268 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
Pradeep LNU ◽  
...  

ABSTRACT Aim Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. Materials and methods In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Results Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. Conclusion All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. Clinical significance In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions. How to cite this article Pandita A, Jain T, Yadav NS, Feroz SMA, Pradeep, Diwedi A. Evaluation and Comparison of Dimensional Accuracy of Newly Introduced Elastomeric Impression Material using 3D Laser Scanners: An in vitro Study. J Contemp Dent Pract 2013;14(2):265-268.


2014 ◽  
Vol 08 (03) ◽  
pp. 366-372 ◽  
Author(s):  
Paula Cristine Ghiggi ◽  
Arno Kieling Steiger ◽  
Maurem Leitão Marcondes ◽  
Eduardo Gonçalves Mota ◽  
Luiz Henrique Burnett ◽  
...  

ABSTRACT Objectives: The objective of the following study is to evaluate the interaction between the resin materials used in immediate dentin sealing (IDS) techniques and impression materials with two different techniques to eliminate the oxygen-inhibition layer. Materials and Methods: The occlusal dentin surface of 35 human molars was exposed. The teeth were used in two Groups: Group 1 – Impression with Express XT; Group 2 – Impression with Impregum. Groups 1 and 2 were divided into 14 subgroups: Groups 1a and 2a – Control groups; 1b and 2b – IDS with Clearfil SE Bond (CSE); 1c and 2c – IDS with CSE + additional polymerization with glycerin jelly; 1d and 2d – IDS with CSE + alcohol; 1e and 2e – IDS with CSE and Protect Liner F (PLF); 1f and 2f – IDS with CSE and PLF + additional polymerization with glycerin jelly; and 1g and 2g – IDS with CSE and PLF + alcohol. Five teeth were used in each experimental group, and the tooth surface was photographed using a digital camera. Results: Small quantity of unpolymerized impression material remained attached to the CSE or to the PLF in Groups 1b and 1e. Groups 1c and 1d prevented the interaction. Small quantity of polymerized impression material remained attached to the CSE or to the PLF for Groups 2b and 2e. The same interaction was observed for Groups 2c and 2d. For Groups 2c and 2f, no interactions were observed. Conclusion: Resin materials interacted with impression materials. The application of glycerin jelly and alcohol prevented the interaction of CSE with Express XT and PLF with Impregum; however, these treatments were not completely effective in preventing the interaction of CSE with Impregum and PLF with Express XT.


2014 ◽  
Vol 3 (2) ◽  
pp. 28-33
Author(s):  
Shakila Fatema ◽  
Sheikh Md Shahriar Quader ◽  
Mohammad Shamsuzzaman ◽  
Mirza Md Arifur Rahman ◽  
Nasima Khan

Background: To achieve accuracy and exact reproduction of prosthesis, choosing a perfect impression material is essential. Especially to make the prosthesis as accurately as possible, impression material should possess some essential properties, like; minimum dimensional changes, good flow ability and easy removal. Purpose: The aim of this study was to evaluate the accuracy and surface detail reproduction of Alginate and Addition Reaction Silicone as an impression materials. Method: This is an experimental in vitro study. In this study Impression by Alginate and Addition Reaction Silicone were made using a round stainless steel test block with three horizontal lines and two vertical lines. The horizontal lines were used for evaluating the surface detail reproduction, and vertical lines were provided for the dimensional accuracy. For dimensional accuracy the length of the middle horizontal line in between vertical lines and the distance between the top and bottom horizontal line was measured using travelling microscope. And for surface detail reproduction three horizontal line of one segment were observed under stereomicroscope. Result: According to study results Addition Reaction Silicone is better than Alginate regarding quality of impression. Conclusion: In comparison to Alginate, Addition Reaction Silicone might have better performance about accuracy and surface detail reproduction. DOI: http://dx.doi.org/10.3329/updcj.v3i2.17996 Update Dent. Coll. j: 2013; 3 (2): 28-33


2014 ◽  
Vol 40 (2) ◽  
pp. 137-145 ◽  
Author(s):  
Malesh Pujari ◽  
Pooja Garg ◽  
D. R. Prithviraj

Movement of impression copings inside the impression material using a direct (open tray) impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the cast. Consequently, the prosthesis may require corrective procedures. This in vitro study evaluated the accuracy of 3 different impression techniques using polyether and vinyl polysiloxane (VPS) impression material to obtain a precise cast for multiple internal connection implants. A reference acrylic resin model with 4 internal connection implants was fabricated. Impressions of the reference model were made using 3 different techniques and 2 different impression materials. The study consisted of 24 specimens divided into 6 groups of 4 each. Impressions were poured with ADA type IV stone (Kalrock, Kalabhai Karson Pvt Ltd, Mumbai, India). All casts were evaluated for the positional accuracy (mm) of the implant replica heads using a profile projector. These measurements were compared to the measurements calculated on the reference resin model, which served as a control. Data were analyzed with 2-way analysis of variance (ANOVA) followed by Bonferroni multiple comparison procedures to evaluate group means. The results revealed significant difference for anterior implant distance between the 2 impression materials (P < .01) and also among the 3 different techniques (P < .05). The lowest mean variation was found with the polyether impression material and the splinted technique. For posterior implants, the results suggested no significant difference between the 2 impression materials (P ≥ .05). Although results were not statistically significant, the polyether impression material showed the lowest mean variation as compared to the VPS impression material. However, there was a significant difference among the 3 different techniques (P < .05). Among the 3 different techniques, the lowest mean variation between 2 posterior implants was found in the splinted technique. Casts obtained from impression techniques using square impression copings splinted together with autopolymerizing acrylic resin prior to the impression procedure were more accurate than casts obtained from impressions with nonmodified implant impression copings and with airborne particle–abraded, adhesive-coated copings. Casts obtained from polyether impression material were more accurate than casts obtained from vinyl polysiloxane impression material.


2020 ◽  
Vol 8 (1) ◽  
Author(s):  
Jinsa P Devassy ◽  
Nishna Pradeep ◽  
A V Sreekumar ◽  
Jimmy George ◽  
Jittin James ◽  
...  

The retentive strength of the impression material to the impression tray is an important factor that can affect the quality of the final impression. Separation of the impression from the tray or tearing of the impression while removing from the mouth could be one of the reasons for distortion. It is imperative to know the most effective tray adhesive which can be used with different brands of rubber-based impression material. So, this study was directed to compare the different tray adhesives that can be effectively used in our day-to-day clinical practice. 


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Ali Hafezeqoran ◽  
Mahdi Rahbar ◽  
Roodabeh Koodaryan ◽  
Tina Molaei

Introduction. The dimensional accuracy of casts is essential in the quality of fixed prosthesis treatment, whereby the impression method is a very crucial factor affecting it. The aim of this in vitro study is to compare the dimensional accuracy of casts resulting from two types of silicone impression materials in different impression techniques and frequent times of cast preparation. Materials and Methods. A metal model was made from two prepared abutments, and 10 casts were prepared from each material technique (n = 40). The impressions were made by condensation and addition silicone (one-stage and two-stage impressions). The casts were made from same impressions 1 h, 24 h, and 14 days. The diameter, height, and the distance between two dies were recorded. Data were analyzed by repeated measure ANOVA (P value <0.05). Results. The dimensional accuracy of all four materials techniques of impression (diameter, height, and the distance between dies) was the same in different times of impression. Dimensional accuracy of the die diameter and distance between dies in one-stage (Speedex) condensation silicon and one-stage (Panasil) addition silicone did not differ significantly, and their one-stage method developed more accurate casts compared to the two-stage method of the same impression material. The height of the casts prepared from the one-stage method through Speedex and Panasil did not differ significantly from the two-stage method of the same impression material. Conclusion. One-stage condensation silicone and one-stage addition silicone material techniques offered the maximum dimensional accuracy in the obtained casts. The time of impression did not have any significant effect in the accuracy of any of the four impression material techniques.


Author(s):  
Abdulrahman Jafar Alhaddad

Aims: The goal of this research is to assess the effect of steam autoclave sterilization due to the impact of Covid-19 on the accuracy of the elastomer impression materials. Study Design: In vitro study. Place and Duration of Study: Department of oral and Maxillofacial Prosthodontics, King Abdul-Aziz University, Jeddah; Saudi Arabia, between June 2021 and November 2021. Methodology: The following materials were used in this study: fully dentate master cast, metal trays, elastomer impression material (addition silicon), type IV stone. Forte impressions made using the metal tray and elastomer impression materials. The impressions were separated equally into two groups: Control group (C.G), untreated impressions. Sterilized group (S.G): Impressions were sterilized by using the steam autoclave. To make stone castings for each group, they were poured with type IV stone. The traveling microscope was used to evaluate the impression material's dimensional accuracy and detail reproduction with and without autoclave sterilization. Results: The cross-arch distance (X) of the master model was measured (41.29 mm), While the cross arch distance (X) in the control group (C.G) of the untreated impressions  had a mean and standard deviation  of 41.492 ± 0.150 mm. In the tested group  (S.G) : the sterilized impression, we found the cross-arch distance (X) had a mean and standard deviation of 41.628 ± 0.223 mm. The master model's Anteroposterior distance (A-P) was measured (21.12 mm). For the control group  (C.G) : we found the mean and standard deviation value reading of the A-P distance were 20.899 ± 0.79 mm. For (S.G) group: we found the mean and standard deviation reading of the A-P distance were 19.992± 0.482 mm. Conclusion: Steam autoclave sterilization of the elastomer impression material should be considered carefully, especially when fabricating fixed partial dentures. If the impression material is to be used in making diagnostic castings, conventional steam autoclave sterilization of the elastomers impression material may be sufficient for patients.


Sign in / Sign up

Export Citation Format

Share Document