scholarly journals Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft

2020 ◽  
Vol 9 (2) ◽  
pp. 303 ◽  
Author(s):  
Márton Kivovics ◽  
Bence Tamás Szabó ◽  
Orsolya Németh ◽  
Dóra Iványi ◽  
Bálint Trimmel ◽  
...  

The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman’s test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88–60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.

Diagnostics ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 368
Author(s):  
Ming-Tzu Tsai ◽  
Rong-Ting He ◽  
Heng-Li Huang ◽  
Ming-Gene Tu ◽  
Jui-Ting Hsu

Assessing bone quality and quantity at the location of dental implants before dental implantation is crucial. In recent years, dental cone-beam computed tomography (dental CBCT) has often been used to assess bone quality and quantity prior to dental implant. However, the effect of scanning resolution on the prediction of trabecular bone microarchitectural parameters (TBMPs) remains unclear. The objective of this study was to examine how dental CBCT with various scanning resolution differs with regard to predicting TBMPs. This study used micro-computed tomography (micro-CT) with 18 μm resolution and dental CBCT with 100 μm and 150 μm resolutions on 28 fresh bovine vertebrae cancellous bone specimens. Subsequently, all images were input into the ImageJ software to measure four TBMPs: bone volume total volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp). One-way analysis of variance and Tukey’s test were subsequently used to assess the differences between three scanning modes for the four TBMPs. In addition, correlations between measurement results obtained from micro-CT and dental CBCT with two resolutions were measured. The experimental results indicated that significant differences in four TBMPs were observed between micro-CT and dental CBCT (p < 0.05). The correlation coefficients between BV/TV, Tb.N, and Tb.Sp obtained from micro-CT and from dental CBCT with 100 μm resolution (0.840, 0.739, and 0.820, respectively) were greater than the correlation coefficients between BV/TV, Tb.N, and Tb.Sp obtained from micro-CT and from dental CBCT with 150 μm resolution (0.758, 0.367, and 0.724, respectively). The experimental results revealed that the TBMPs measured with dental CBCT with two resolutions differed from ideal values, but a higher resolution could provide more accurate prediction results, particularly for BV/TV, Tb.N, and Tb.Sp.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Corina Marilena Cristache

Despite numerous advantages over multislice computed tomography (MSCT), including a lower radiation dose to the patient, shorter acquisition times, affordable cost, and sometimes greater detail with isotropic voxels used in reconstruction, allowing precise measurements, cone beam computed tomography (CBCT) is still controversial regarding bone quality evaluation. This paper presents a brief review of the literature on accuracy and reliability of bone quality assessment with CBCT and a case report with step-by-step predictable treatment planning in esthetic zone, based on CBCT scans which enabled the clinician to evaluate, depending on bone volume and quality, whether immediate restoration with CAD-CAM manufactured temporary crown and flapless surgery may be a treatment option.


2021 ◽  
Vol 15 (1) ◽  
pp. 57-63
Author(s):  
Lauren Bohner ◽  
Pedro Tortamano ◽  
Felix Gremse ◽  
Israel Chilvarquer ◽  
Johannes Kleinheinz ◽  
...  

Background: Cone-Beam Computed Tomography (CBCT) with high-resolution parameters may provide an acceptable resolution for bone assessment. Objectives: The purpose of this study is to assess trabecular bone using two cone-beam computed tomography (CBCT) devices with high-resolution parameters in comparison to micro-computed tomography (µCT). Methods: Bone samples (n=8) were acquired from dry mandibles and scanned by two CBCT devices: 1) VV (Veraview R100, Morita; FOV 4x4, 75kV, 9mA, voxel size 0.125µm); and PR (Prexion 3D, Prexion; FOV 5x5, 90kV, 4mA, 37s, voxel size 108µm). Gold-standard images were acquired using µCT (SkyScan 1272; Bruker; 80kV, 125mA, voxel size 16µm). Morphometric parameters (BvTv- Bone Volume Fraction, BsBv- Trabecular specific surface, TbTh- Trabecular thickness and TbSp- Trabecular separation) were measured. Statistical analysis was performed within ANOVA, Spearman Correlation test and Bland-Altmann plots with a statistical significance level at p=0.05. Results: CBCT devices showed similar BvTv values in comparison to µCT. No statistical difference was found for BvTv parameters assessed by CBCT devices and µCT. BsBv values were underestimated by CBCT devices (p<0.01), whereas TbTh and TbSp values were overestimated by them (p<0.01). Positive correlations were found between VV and µCT measurements for BvTv (r2= 0.65, p=0.00), such as between PR and µCT measurements for TbSp (r2= 0.50, p=0.04). For BsBv measurements, PR was negatively correlated with µCT (r2= -0.643, p=0.01). Conclusion: The evaluated CBCT device was able to assess trabecular bone. However, bone parameters were under or overestimated in comparison to µCT.


2020 ◽  
Author(s):  
Yalin Zhan ◽  
Miaozhen Wang ◽  
Xueyuan Cheng ◽  
Feng Liu

Abstract Background: Sagittal root position (SRP) and thickness of buccal plate were of clinical guiding significance in implant treatment planning. The study was to classify the SRP and angulations of the maxillary and mandibular premolar to each osseous housing, and to measure the thickness of buccal plate by cone beam computed tomography (CBCT) in order to estimate the distributions and provide clinical decision support. Methods: CBCT images was reviewed on 150 patients who fulfilled the inclusion criteria. The sagittal root position and angulations of the maxillary and mandibular premolars to their respective osseous housing were evaluated and classified using CBCT images. The thickness of buccal plate at 1 mm, 3 mm, 5 mm apical to the alveolar crest was also measured. Results: The frequency distribution of SRP types indicated that, 41.67%, 51.83%, 3.67%, and 2.83% of maxillary premolars; 84.33%, 15%, 0%, and 0.67% of mandibular premolars were classified as type B, M, L, and N. The frequency distribution of angulation classifications indicated that, 20.83%, 46%, 32.17%, and 1% of maxillary premolars; 2%, 5.33%, 36.67%, and 56% of mandibular premolars were classified as class 1, 2, 3, and 4. The buccal bone thickness in most locations of premolar sites was less than 1 mm. Conclusions: The classification of clinical relevance of SRP and angulation of the premolar root to osseous housing would help for treatment planning and improving interdisciplinary communication of immediate implant placement (IIP) in the premolar region.


2020 ◽  
Vol 54 (4) ◽  
pp. 325-331
Author(s):  
Kalyani Trivedi ◽  
Bharvi K Jani ◽  
Sagar Hirani ◽  
Mansi V Radia

Aim: The purpose of this study was to use measurements from cone beam computed tomography scans to quantify the cortical bone thickness of mandibular buccal shelf region and preferable site for buccal shelf implant placement in 10 hyperdivergent and 10 hypodivergent patients. Method: 20 cone beam computed tomographies were equally divided based on divergence. 6 sites were examined: mesial of first molar (6M), middle of first molar (6Mi), interdental between the first and second molar (Id), mesial of second molar (7M), middle of second molar (7Mi), and distal of second molar (7D). The study quantified the mandibular buccal shelf relative to its angle of slope, the cortical bone thickness measured perpendicular to the bone surface, the amount of cortical bone 30° angle to the bone surface. The cortical bone thickness was measured perpendicular and at a 30° angle at 3, 5, and 7 mm from the alveolar crest. Result: Significant change is seen at the buccal shelf slope at 6M ( P = .001) and further increase in this angle till 7D ( P = .003). Mean amount of cortical bone for hyperdivergent group at 7D is 4.77 ± 0.68 mm and for hypodivergent group is 3.86 ± 0.70 mm. Statistically significant differences were noted at insertion site at 90° and 30° for both groups at 3, 5, and 7 mm from the alveolar crest. Conclusion: Preferable site for buccal shelf implant placement is distal to the mandibular second molar. The maximum amount of cortical bone is found distal to the second molar 7 mm vertically from alveolar crest when the buccal shelf implant is placed at 30° angulation for hyperdivergent group.


2013 ◽  
Vol 2013 ◽  
pp. 1-12
Author(s):  
Vijay Shekhar ◽  
K. Shashikala

The aim of this case report is to present two cases where cone beam computed tomography (CBCT) was used for the diagnosis, treatment planning, and followup of large periapical lesions in relation to maxillary anterior teeth treated by endodontic surgery. Periapical disease may be detected sooner using CBCT, and their true size, extent, nature, and position can be assessed. It allows clinician to select the most relevant views of the area of interest resulting in improved detection of periapical lesions. CBCT scan may provide a better, more accurate, and faster method to differentially diagnose a solid (granuloma) from a fluid-filled lesion or cavity (cyst). In the present case report, endodontic treatment was performed for both the cases followed by endodontic surgery. Biopsy was done to establish the confirmatory histopathological diagnosis of the periapical lesions. Long-term assessment of the periapical healing following surgery was done in all the three dimensions using CBCT and was found to be more accurate than IOPA radiography. It was concluded that CBCT was a useful modality in making the diagnosis and treatment plan and assessing the outcome of endodontic surgery for large periapical lesions.


Sign in / Sign up

Export Citation Format

Share Document