scholarly journals Effect of Scanning Resolution on the Prediction of Trabecular Bone Microarchitectures Using Dental Cone Beam Computed Tomography

Diagnostics ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 368
Author(s):  
Ming-Tzu Tsai ◽  
Rong-Ting He ◽  
Heng-Li Huang ◽  
Ming-Gene Tu ◽  
Jui-Ting Hsu

Assessing bone quality and quantity at the location of dental implants before dental implantation is crucial. In recent years, dental cone-beam computed tomography (dental CBCT) has often been used to assess bone quality and quantity prior to dental implant. However, the effect of scanning resolution on the prediction of trabecular bone microarchitectural parameters (TBMPs) remains unclear. The objective of this study was to examine how dental CBCT with various scanning resolution differs with regard to predicting TBMPs. This study used micro-computed tomography (micro-CT) with 18 μm resolution and dental CBCT with 100 μm and 150 μm resolutions on 28 fresh bovine vertebrae cancellous bone specimens. Subsequently, all images were input into the ImageJ software to measure four TBMPs: bone volume total volume fraction (BV/TV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp). One-way analysis of variance and Tukey’s test were subsequently used to assess the differences between three scanning modes for the four TBMPs. In addition, correlations between measurement results obtained from micro-CT and dental CBCT with two resolutions were measured. The experimental results indicated that significant differences in four TBMPs were observed between micro-CT and dental CBCT (p < 0.05). The correlation coefficients between BV/TV, Tb.N, and Tb.Sp obtained from micro-CT and from dental CBCT with 100 μm resolution (0.840, 0.739, and 0.820, respectively) were greater than the correlation coefficients between BV/TV, Tb.N, and Tb.Sp obtained from micro-CT and from dental CBCT with 150 μm resolution (0.758, 0.367, and 0.724, respectively). The experimental results revealed that the TBMPs measured with dental CBCT with two resolutions differed from ideal values, but a higher resolution could provide more accurate prediction results, particularly for BV/TV, Tb.N, and Tb.Sp.

2020 ◽  
Vol 9 (2) ◽  
pp. 303 ◽  
Author(s):  
Márton Kivovics ◽  
Bence Tamás Szabó ◽  
Orsolya Németh ◽  
Dóra Iványi ◽  
Bálint Trimmel ◽  
...  

The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman’s test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88–60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability.


2021 ◽  
Vol 15 (1) ◽  
pp. 57-63
Author(s):  
Lauren Bohner ◽  
Pedro Tortamano ◽  
Felix Gremse ◽  
Israel Chilvarquer ◽  
Johannes Kleinheinz ◽  
...  

Background: Cone-Beam Computed Tomography (CBCT) with high-resolution parameters may provide an acceptable resolution for bone assessment. Objectives: The purpose of this study is to assess trabecular bone using two cone-beam computed tomography (CBCT) devices with high-resolution parameters in comparison to micro-computed tomography (µCT). Methods: Bone samples (n=8) were acquired from dry mandibles and scanned by two CBCT devices: 1) VV (Veraview R100, Morita; FOV 4x4, 75kV, 9mA, voxel size 0.125µm); and PR (Prexion 3D, Prexion; FOV 5x5, 90kV, 4mA, 37s, voxel size 108µm). Gold-standard images were acquired using µCT (SkyScan 1272; Bruker; 80kV, 125mA, voxel size 16µm). Morphometric parameters (BvTv- Bone Volume Fraction, BsBv- Trabecular specific surface, TbTh- Trabecular thickness and TbSp- Trabecular separation) were measured. Statistical analysis was performed within ANOVA, Spearman Correlation test and Bland-Altmann plots with a statistical significance level at p=0.05. Results: CBCT devices showed similar BvTv values in comparison to µCT. No statistical difference was found for BvTv parameters assessed by CBCT devices and µCT. BsBv values were underestimated by CBCT devices (p<0.01), whereas TbTh and TbSp values were overestimated by them (p<0.01). Positive correlations were found between VV and µCT measurements for BvTv (r2= 0.65, p=0.00), such as between PR and µCT measurements for TbSp (r2= 0.50, p=0.04). For BsBv measurements, PR was negatively correlated with µCT (r2= -0.643, p=0.01). Conclusion: The evaluated CBCT device was able to assess trabecular bone. However, bone parameters were under or overestimated in comparison to µCT.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Corina Marilena Cristache

Despite numerous advantages over multislice computed tomography (MSCT), including a lower radiation dose to the patient, shorter acquisition times, affordable cost, and sometimes greater detail with isotropic voxels used in reconstruction, allowing precise measurements, cone beam computed tomography (CBCT) is still controversial regarding bone quality evaluation. This paper presents a brief review of the literature on accuracy and reliability of bone quality assessment with CBCT and a case report with step-by-step predictable treatment planning in esthetic zone, based on CBCT scans which enabled the clinician to evaluate, depending on bone volume and quality, whether immediate restoration with CAD-CAM manufactured temporary crown and flapless surgery may be a treatment option.


2010 ◽  
Vol 80 (1) ◽  
pp. 160-166 ◽  
Author(s):  
Yi Liu ◽  
Raphael Olszewski ◽  
Emanuel Stefan Alexandroni ◽  
Reyes Enciso ◽  
Tianmin Xu ◽  
...  

Abstract Objective: To determine the accuracy of volumetric analysis of teeth in vivo using cone-beam computed tomography (CBCT). Materials and Methods: The physical volume (Vw) of 24 bicuspids extracted for orthodontic purposes (16 were imaged with the I-CAT and 8 with the CB MercuRay) were determined using the water displacement technique. Corresponding pretreatment CBCT image data were uploaded into Amira 4.0 for segmentation and radiographic volume (Va). All measurements were performed twice by two observers. The statistical difference between Vw and Va was assessed using a paired t-test. The intraobserver and interobserver reliability were determined by calculating Pearson correlation coefficients and intraclass correlation coefficients. Results: The overall mean Vw of teeth specimens was 0.553 ± 0.082 cm3, while the overall mean Va was 0.548 ± 0.079 cm3 (0.529 ± 0.078 cm3 for observer 1 and 0.567 ± 0.085 cm3 for observer 2). There were statistically significant differences between Va and Vw (P &lt; .05). Between observer 1 and observer 2, Va measurements were statistically significantly different (P &lt; .05). The interobserver and intraobserver correlation coefficient for Vw was high. Lastly, surface smoothing reduced the volume by 3% to 12%. Conclusions: In vivo determination of tooth volumes from CBCT data is feasible. The measurements slightly deviate from the physical volumes within −4% to 7%. Smoothing operations reduce volume measurements. Currently, no requirements for accuracy of volumetric determinations of tooth volume have been established.


2012 ◽  
Vol 24 (2) ◽  
Author(s):  
Shaliha Shaliha ◽  
Ria Noerianingsih Firman ◽  
Yanti Rusyanti

Introduction: Periodontitis is an inflamatory process in supporting tissues of the teeth including the gingiva, cementum, periodontal ligament and alveolar bone. Perioditis ntitis begins with migration of junctional ephithelium toward the apical side and form a pocket on gingiva. Aggressive periodontitis is one of the classifications of periodontitis with characteristics of attacking teens to young adults in relatively fast can lead to severe alveolar bone loss and it is not comparable with local factors that there. Trabeculae are part of the alveolar bone covered by compact bone and cortical bone harder . On radiographs, trabeculae only seen as a radiolucent surrounded by a radiopaque. The purpose of this research was to know the description of alveolar trabecular bone in patients with aggressive periodontitis using Cone Beam Computed Tomography imaging. Methods: This study is descriptive on 72 samples of aggressive periodontitis alveolar travecular bon e by CBCT imaging, taken from 6 archival aggressive periodontitis patients as research subjects, obtained from secondary data in the Radiology Department of RSGM FKG UNPAD. Results: The results of this study from the 3D CBCT imaging of alveolar trabecular bone leading to further describe the more posterior a decline in trabecular bone density and decrease in patients with aggressive periodontitis. Conclusion: The 3D CBCT imaging of alveolar trabecular bone leading to further describe the more posterior a decline in trabecular bone density and decrease in patients with aggressive periodontitis.