Currently, voided urine cytology (VUC) serves as the gold standard for the detection of bladder cancer (BCa) in urine. Despite its high specificity, VUC has shortcomings in terms of sensitivity. Therefore, alternative biomarkers are being searched, which might overcome these disadvantages as a useful adjunct to VUC. The aim of this study was to evaluate the diagnostic potential of the urinary levels of selected microRNAs (miRs), which might represent such alternative biomarkers due to their BCa-specific expression. Expression levels of nine BCa-associated microRNAs (miR-21, -96, -125b, -126, -145, -183, -205, -210, -221) were assessed by quantitative PCR in urine sediments from 104 patients with primary BCa and 46 control subjects. Receiver operating characteristic (ROC) curve analyses revealed a diagnostic potential for miR-96, -125b, -126, -145, -183, and -221 with area under the curve (AUC) values between 0.605 and 0.772. The combination of the four best candidates resulted in sensitivity, specificity, positive and negative predictive values (NPV), and accuracy of 73.1%, 95.7%, 97.4%, 61.1%, and 80.0%, respectively. Combined with VUC, sensitivity and NPV could be increased by nearly 8%, each surpassing the performance of VUC alone. The present findings suggested a diagnostic potential of miR-125b, -145, -183, and -221 in combination with VUC for non-invasive detection of BCa in urine.

2019 ◽  
Vol 36 (6) ◽  
pp. 530-538
Author(s):  
Nicolò Tamini ◽  
Davide Paolo Bernasconi ◽  
Luca Gianotti

Aim of the Study: The diagnosis of choledocholithiasis is challenging. Previously published scoring systems designed to calculate the risk of choledocholithiasis were evaluated to appraise the diagnostic performance. Patients and Methods: Data of patients who were admitted between 2013 and 2015 with the following characteristics were retrieved: bile stone-related symptoms and signs, and indication to laparoscopic cholecystectomy. To validate and appraise the performance of the 6 scoring systems, the acknowledged domains of each metrics were applied to the present cohort. Sensitivity, specificity, positive, negative predictive, Youden index, and receiver operating characteristic curve with the area under the curve (AUC) values of the scores were calculated. Results: Two-hundred patients were analyzed. The highest sensitivity and specificity were obtained from the Menezes’ (96.6%) and Telem’s (99.3%) metrics respectively. The Telem’s and Menezes’ scores had the best positive (75.0%) and negative (96.4%) predictive values respectively. The best accuracy, as computed by the Youden index and AUC, was found for the Soltan’s scoring system (0.628 and 0.88, respectively). Conclusion: The available scoring systems are precise only in identifying patients with a negligible risk of common bile duct stone, but overall insufficiently accurate to suggest the routine use in clinical practice.


2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Shuko Tokuriki ◽  
Takashi Okuno ◽  
Genrei Ohta ◽  
Yusei Ohshima

Objective. To evaluate the usefulness of carboxyhemoglobin (CO-Hb) levels as a biomarker to predict the development and severity of bronchopulmonary dysplasia (BPD).Methods. Twenty-five infants born at <33 wk of gestational age or with a birth weight of <1,500 g were enrolled. CO-Hb levels were measured between postnatal days 5 and 8, 12 and 15, 19 and 22, and 26 and 29. Urinary levels of 8-hydroxydeoxyguanosine (8-OHdG), advanced oxidation protein products, and Nε-(hexanoyl) lysine were measured between postnatal days 5 and 8 and 26 and 29. Receiver operating characteristic (ROC) analysis was used to compare the biomarkers’ predictive values.Results. Compared with infants in the no-or-mild BPD group, infants with moderate-to-severe BPD exhibited higher CO-Hb levels during the early postnatal period and higher 8-OHdG levels between postnatal days 5 and 8. Using ROC analysis to predict the development of moderate-to-severe BPD, the area under the curve (AUC) for CO-Hb levels between postnatal days 5 and 8 was higher than AUCs for the urinary markers.Conclusions. CO-Hb levels during the early postnatal period may serve as a practical marker for evaluating oxidative stress and the severity of subsequently developing BPD.


Entropy ◽  
2020 ◽  
Vol 22 (7) ◽  
pp. 729 ◽  
Author(s):  
Peter Oehr ◽  
Thorsten Ecke

Background: This investigation included both a study of potential non-invasive diagnostic approaches for the bladder cancer biomarker UBC® Rapid Test and a study including comparative methods about sensitivity–specificity characteristic (SS-ROC) and predictive receiver operating characteristic (PV-ROC) curves that used bladder cancer as a useful example. Methods: The study included 289 urine samples from patients with tumors of the urinary bladder, patients with non-evidence of disease (NED) and healthy controls. The UBC® Rapid Test is a qualitative point of care assay. Using a photometric reader, quantitative data can also be obtained. Data for pairs of sensitivity/specificity as well as positive/negative predictive values were created by variation of threshold values for the whole patient cohort, as well as for the tumor-free control group. Based on these data, sensitivity–specificity and predictive value threshold distribution curves were constructed and transformed into SS-ROC and PV-ROC curves, which were included in a single SS/PV-ROC plot. Results: The curves revealed TPP-asymmetric improper curves which cross the diagonal from above. Evaluation of the PV-ROC curve showed that two or more distinct positive predictive values (PPV) can correspond to the same value of a negative predictive value (NPV) and vice versa, indicating a complexity in PV-ROC curves which did not exist in SS-ROC curves. In contrast to the SS-ROC curve, the PV-ROC curve had neither an area under the curve (AUC) nor a range from 0% to 100%. Sensitivity of the qualitative assay was 58.5% and specificity 88.2%, PPV was 75.6% and NPV 77.3%, at a threshold value of approximately 12.5 µg/L. Conclusions: The SS/PV-ROC plot is a new diagnostic approach which can be used for direct judgement of gain and loss of predictive values, sensitivity and specificity according to varied threshold value changes, enabling characterization, comparison and evaluation of qualitative and quantitative bioassays.


2020 ◽  
Vol 163 (6) ◽  
pp. 1156-1165
Author(s):  
Juan Xiao ◽  
Qiang Xiao ◽  
Wei Cong ◽  
Ting Li ◽  
Shouluan Ding ◽  
...  

Objective To develop an easy-to-use nomogram for discrimination of malignant thyroid nodules and to compare diagnostic efficiency with the Kwak and American College of Radiology (ACR) Thyroid Imaging, Reporting and Data System (TI-RADS). Study Design Retrospective diagnostic study. Setting The Second Hospital of Shandong University. Subjects and Methods From March 2017 to April 2019, 792 patients with 1940 thyroid nodules were included into the training set; from May 2019 to December 2019, 174 patients with 389 nodules were included into the validation set. Multivariable logistic regression model was used to develop a nomogram for discriminating malignant nodules. To compare the diagnostic performance of the nomogram with the Kwak and ACR TI-RADS, the area under the receiver operating characteristic curve, sensitivity, specificity, and positive and negative predictive values were calculated. Results The nomogram consisted of 7 factors: composition, orientation, echogenicity, border, margin, extrathyroidal extension, and calcification. In the training set, for all nodules, the area under the curve (AUC) for the nomogram was 0.844, which was higher than the Kwak TI-RADS (0.826, P = .008) and the ACR TI-RADS (0.810, P < .001). For the 822 nodules >1 cm, the AUC of the nomogram was 0.891, which was higher than the Kwak TI-RADS (0.852, P < .001) and the ACR TI-RADS (0.853, P < .001). In the validation set, the AUC of the nomogram was also higher than the Kwak and ACR TI-RADS ( P < .05), each in the whole series and separately for nodules >1 or ≤1 cm. Conclusions When compared with the Kwak and ACR TI-RADS, the nomogram had a better performance in discriminating malignant thyroid nodules.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Lei Xi ◽  
Chunqing Yang

AbstractObjectivesThe main aim of the present study was to assess the diagnostic value of alpha-l-fucosidase (AFU) for hepatocellular carcinoma (HCC).MethodsStudies that explored the diagnostic value of AFU in HCC were searched in EMBASE, SCI, and PUBMED. The sensitivity, specificity, and DOR about the accuracy of serum AFU in the diagnosis of HCC were pooled. The methodological quality of each article was evaluated with QUADAS-2 (quality assessment for studies of diagnostic accuracy 2). Receiver operating characteristic curves (ROC) analysis was performed. Statistical analysis was conducted by using Review Manager 5 and Open Meta-analyst.ResultsEighteen studies were selected in this study. The pooled estimates for AFU vs. α-fetoprotein (AFP) in the diagnosis of HCC in 18 studies were as follows: sensitivity of 0.7352 (0.6827, 0.7818) vs. 0.7501 (0.6725, 0.8144), and specificity of 0.7681 (0.6946, 0.8283) vs. 0.8208 (0.7586, 0.8697), diagnostic odds ratio (DOR) of 7.974(5.302, 11.993) vs. 13.401 (8.359, 21.483), area under the curve (AUC) of 0.7968 vs. 0.8451, respectively.ConclusionsAFU is comparable to AFP for the diagnosis of HCC.


Author(s):  
Luma Cordeiro Rodrigues ◽  
Silvia Ferrite ◽  
Ana Paula Corona

Abstract Purpose This article investigates the validity of a smartphone-based audiometry for hearing screening to identify hearing loss in workers exposed to noise. Research Design This is a validation study comparing hearing screening with the hearTest to conventional audiometry. The study population included all workers who attended the Brazilian Social Service of Industry to undergo periodic examinations. Sensitivity, specificity, the Youden index, and positive (PPV) and negative predictive values (NPV) for hearing screening obtained by the hearTest were estimated according to three definitions of hearing loss: any threshold greater than 25 dB hearing level (HL), the mean auditory thresholds for 0.5, 1, 2, and 4 kHz greater than 25 dB HL, and the mean thresholds for 3, 4, and 6 kHz greater than 25 dB HL. Note that 95% confidence intervals were calculated for all measurements. Results A total of 232 workers participated in the study. Hearing screening with the hearTest presented good sensitivity (93.8%), specificity (83.9%), and Youden index (77.7%) values, a NPV (97.2%), and a low PPV (69.0%) for the identification of hearing loss defined as any auditory threshold greater than 25 dB HL. For the other definitions of hearing loss, we observed high specificity, PPV and NPV, as well as low sensitivity and Youden index. Conclusion The hearTest is an accurate hearing screening tool to identify hearing loss in workers exposed to noise, including those with noise-induced hearing loss, although it does not replace conventional audiometry.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Bo Yao ◽  
Wen-juan Liu ◽  
Di Liu ◽  
Jin-yan Xing ◽  
Li-juan Zhang

Abstract Background Early diagnosis of sepsis is very important. It is necessary to find effective and adequate biomarkers in order to diagnose sepsis. In this study, we compared the value of sialic acid and procalcitonin for diagnosing sepsis. Methods Newly admitted intensive care unit patients were enrolled from January 2019 to June 2019. We retrospectively collected patient data, including presence of sepsis or not, procalcitonin level and sialic acid level. Receiver operating characteristic curves for the ability of sialic acid, procalcitonin and combination of sialic acid and procalcitonin to diagnose sepsis were carried out. Results A total of 644 patients were admitted to our department from January 2019 to June 2019. The incomplete data were found in 147 patients. Finally, 497 patients data were analyzed. The sensitivity, specificity and area under the curve for the diagnosis of sepsis with sialic acid, procalcitonin and combination of sialic acid and procalcitonin were 64.2, 78.3%, 0.763; 67.9, 84.0%, 0.816 and 75.2, 84.6%, 0.854. Moreover, sialic acid had good values for diagnosing septic patients with viral infection, with 87.5% sensitivity, 82.2% specificity, and 0.882 the area under the curve. Conclusions Compared to procalcitonin, sialic acid had a lower diagnostic efficacy for diagnosing sepsis in critically ill patients. However, the combination of sialic acid and procalcitonin had a higher diagnostic efficacy for sepsis. Moreover, sialic acid had good value for diagnosing virus-induced sepsis.


2012 ◽  
Vol 9 (1) ◽  
pp. 71-77 ◽  
Author(s):  
Michael W. Beets ◽  
Aaron Beighle ◽  
Matteo Bottai ◽  
Laura Rooney ◽  
Fallon Tilley

Background:Policies to require afterschool programs (ASPs, 3 PM to 6 PM) to provide children a minimum of 30 minutes of moderate-to-vigorous physical activity (MVPA) exist. With few low-cost, easy-to-use measures of MVPA available to the general public, ASP providers are limited in their ability to track progress toward achieving this policy-goal. Pedometers may fill this gap, yet there are no step-count guidelines for ASPs linked to 30 minutes of MVPA.Methods:Steps and accelerometer estimates of MVPA were collected concurrently over multiple days on 245 children (8.2 years, 48% boys, BMI-percentile 68.2) attending 3 community-based ASPs. Random intercept logit models and receiver operating characteristic (ROC) analyses were used to identify a threshold of steps that corresponded with attaining 30 minutes of MVPA.Results:Children accumulated an average of 2876 steps (standard error [SE] 79) and 16.1 minutes (SE0.5) of MVPA over 111 minutes (SE1.3) during the ASP. A threshold of 4600 steps provided high specificity (0.967) and adequate sensitivity (0.646) for discriminating children who achieved the 30 minutes of MVPA; 93% of the children were correctly classified. The total area under the curve was 0.919. Children accumulating 4600 steps were 25times more likely to accumulate 30 minutes of MVPA.Conclusions:This step threshold will provide ASP leaders with an objective, low-cost, easy-to-use tool to monitor progress toward policy-related goals.


2008 ◽  
Vol 9 (4) ◽  
pp. 278-284 ◽  
Author(s):  
P.P.G.M. Rooijens ◽  
G.P Serafino ◽  
D. Vroegindeweij ◽  
R. Dammers ◽  
T.I. Yo ◽  
...  

Purpose A method of diagnosing the extent and severity of arteriovenous fistula (AVF) stenoses is multi-slice computed tomographic angiography (MS-CTA). The aim of this prospective study was to assess the accuracy of MS-CTA for the detection and grading of stenoses in AVF in comparison to digital subtraction angiography (DSA), which was used as the gold standard of reference. Methods Fifteen hemodialysis (HD) patients with dysfunctioning forearm AVF were included. These AVFs were evaluated by both DSA and MS-CTA and were read in a prospective, blinded manner by two radiologists experienced in vascular imaging. Results ROC analysis revealed areas under the curve of 0.90 ± 0.07 for observer I and 0.87 ± 0.08 for observer II at a stenosis cut-off level of ≥50% diameter reduction. The combined results for MS-CTA showed sensitivity, specificity and positive and negative predictive values of 82%, 98%, 82% and 98% for stenoses ≥50% and 71%, 99%, 77% and 98% for stenoses ≥75%. Inter-observer agreement for the detection of stenoses ≥50% diameter reduction was 0.70 and 1.0, for MS-CTA and DSA, respectively. Conclusion MS-CTA can provide good visualization of forearm HD access AVF and has moderate sensitivity, but high specificity for the detection of flow-limiting stenoses.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.